Multiwire Copper & Aluminum Conductors Class 2 – IEC 60228

The multiwire copper and aluminum conductors (Class 2) deliver dependable electrical conductivity for a wide range of cable applications. Constructed with multiple stranded wires to enhance flexibility, they are available in various cross-sections and comply with IEC 60228, DIN VDE 0295, and BS 6360 standards. Because they offer precise resistance values and robust construction, they provide a safe and reliable solution for industrial, commercial, and infrastructure wiring.

Application
Multiwire copper and aluminum conductors provide the foundational conductive elements for a wide range of cables and electrical wiring. Because they are stranded (Class 2), installers use them in applications requiring greater flexibility than solid conductors. Furthermore, these conductors are engineered for reliable electrical transmission in industrial, commercial, and infrastructure settings. Consequently, they ensure consistent performance and durability in demanding electrical environments.

Cable construction
These conductors strictly adhere to IEC 60228, DIN VDE 0295, and BS 6360 standards. They are available in both copper and aluminum variants. The construction features multiple wires stranded together to form the specific nominal cross-section. The stranding and wire diameter are meticulously controlled to meet the precise electrical resistance requirements of Class 2 conductors.

Technical Data
The conductors deliver consistent performance under specific conditions. The electrical resistance at 20 °C is strictly controlled according to the nominal cross-section. For example, copper conductors range from 26.0 Ω/km (0.25 mm²) down to 0.0366 Ω/km (500 mm²), while aluminum conductors range from 7.41 Ω/km (4.0 mm²) down to 0.0605 Ω/km (500 mm²). The construction ensures optimal conductivity and minimal power loss across all available sizes.

Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, stranding, and electrical resistance information.

Construction data Cu/Al conductors class 2

Nominal cross-section Stranding and wire diameter Electrical resistance at 20°C, max
mm² N x mm Copper conductors (Ω/km) Aluminum conductors (Ω/km)
0,25 7/0,21 26,0 –
0,75 7/0,37 24,5 –
1,00 7/0,44 18,1 –
1,50 7/0,53 12,1 –
2,50 7/0,67 7,41 7,41
4,0 7/0,85 4,61 4,61
6,0 7/1,05 3,08 3,08
10,0 7/1,35 1,83 3,08
16,0 7/1,70 1,15 1,91
25 7/2,15 0,727 1,20
35 7/2,50 0,524 0,868
50 19/1,78 0,387 0,641
70 19/2,14 0,268 0,443
95 19/2,50 0,193 0,320
120 37/2,03 0,153 0,253
150 37/2,25 0,124 0,206
185 37/2,50 0,0991 0,164
240 61/2,25 0,0754 0,125
300 61/2,50 0,0601 0,100
400 61/2,85 0,0470 0,0778
500 61/3,20 0,0366 0,0605

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of these multiwire conductors?
A:- They are used as the conductive elements for cables and conductors across various industrial, commercial, and infrastructure applications.

Q:- What are the key benefits of Class 2 stranded conductors?
A:- Class 2 stranding provides greater flexibility and bendability compared to solid conductors, making installation easier while maintaining excellent electrical conductivity.

Q:- What standards do these conductors follow?
A:- They strictly adhere to IEC 60228, DIN VDE 0295, and BS 6360 standards.

Q:- What materials are available for these conductors?
A:- They are available in both high-conductivity copper and lightweight aluminum variants.

Q:- What is the smallest cross-section available for copper conductors?
A:- The smallest copper cross-section available is 0.25 mm², with a stranding of 7/0.21 and a resistance of 26.0 Ω/km.

Q:- What is the largest cross-section available for both copper and aluminum?
A:- The largest cross-section available for both materials is 500 mm², with a stranding of 61/3.20.

Q:- How is the electrical resistance of the conductors specified?
A:- The electrical resistance is strictly specified at a maximum value at 20°C (Ω/km) for each nominal cross-section to ensure predictable performance.

Q:- Why are the resistance values different for copper and aluminum?
A:- Aluminum has a higher electrical resistance than copper, so a larger aluminum cross-section is required to achieve the same conductivity as a smaller copper conductor.

Q:- Is the stranding pattern consistent across all sizes?
A:- No, the stranding pattern (number of wires and their diameter) increases with the nominal cross-section to optimize flexibility and conductivity.

Q:- Are these conductors suitable for high-temperature applications?
A:- The resistance values are specified at 20°C. The maximum operating temperature will depend on the final insulation and sheathing applied to the cable.