H07Z-U/R/K LSOH Single-Core Cable – BS 7211 Standard
The H07Z-U/R/K cable delivers dependable electrical connections for protected installations where fire safety is critical. Constructed with copper conductors and low smoke zero halogen (LSOH) thermosetting insulation, it offers exceptional protection by minimizing smoke and toxic fumes. Because it meets BS 7211 standards and is CE/RoHS compliant, it provides a safe and reliable solution for conduit and fixed installations in environments where fire poses a potential threat.
Application
H07Z-U/R/K cables provide reliable electrical connections for protected installations where safety is critical. Because they feature low smoke zero halogen (LSOH) insulation, installers use them in conduit and fixed installations. Furthermore, they are specifically designed for environments where fire, smoke emission, and toxic fumes create a potential threat. Additionally, they protect human life and sensitive equipment by ensuring low emission of smoke and corrosive gases when affected by fire.
Cable construction
This cable strictly adheres to BS 7211 standards. It features copper wires according to BS 6360, class 1, 2, or 5. The insulation uses a Type EI 5, low smoke, zero halogen, thermosetting compound. Available colors include black, red, blue, pink, grey, yellow, green, brown, white, violet, and orange. Two-color combinations are not permitted except for green/yellow. Furthermore, this product is both RoHS and CE compliant.
Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to BS 6360. The maximum core temperature is 90 °C in operation. The insulation resistance is according to BS 7211. It operates at a rated voltage of 450/750 V and undergoes a test voltage of AC 50 Hz at 2500 V. The temperature range is mobile -5 °C to +70 °C and fixed -40 °C to +70 °C. Installers must respect a minimum bending radius of 10 times the cable diameter for diameters up to 10mm, and 15 times for larger sizes. The flame propagation test follows BS 4066-1, and the smoke emission test follows BS 7622.
Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.
Construction data H07Z-U/R/K 450/750V
| Nominal cross section | Approx. outer diameter | Copper weight | Cable weight approx. |
|---|---|---|---|
| mm² | mm | kg/km | kg/km |
| H07Z-U | |||
| 1.5 | 2,8 | 14 | 20 |
| 2.5 | 3,4 | 22 | 29 |
| 4.0 | 3,8 | 36 | 45 |
| 6.0 | 4,1 | 52 | 64 |
| 10 | 5,5 | 90 | 107 |
| H07Z-R | |||
| 1.5 | 3,0 | 13 | 21 |
| 2.5 | 3,6 | 21 | 33 |
| 4.0 | 4,1 | 34 | 46 |
| 6.0 | 4,7 | 52 | 68 |
| 10 | 6,3 | 87 | 112 |
| 16 | 7,4 | 139 | 165 |
| 25 | 9,1 | 221 | 265 |
| 35 | 10,4 | 300 | 349 |
| 50 | 12,4 | 455 | 509 |
| 70 | 12,5 | 601 | 666 |
| 95 | 14,6 | 835 | 922 |
| 120 | 16,6 | 1071 | 1140 |
| 150 | 17,8 | 1359 | 1418 |
| 185 | 19,9 | 1629 | 1773 |
| H07Z-K | |||
| 1.5 | 3,0 | 13 | 20 |
| 2.5 | 3,6 | 21 | 30 |
| 4.0 | 4,1 | 35 | 45 |
| 6.0 | 4,7 | 52 | 66 |
| 10 | 6,6 | 95 | 118 |
| 16 | 7,6 | 147 | 173 |
| 25 | 9,5 | 224 | 266 |
| 35 | 10,4 | 331 | 377 |
| 50 | 12,8 | 446 | 509 |
| 70 | 14,6 | 631 | 700 |
| 95 | 17,4 | 842 | 921 |
| 120 | 19,6 | 1075 | 1160 |
| 150 | 21,0 | 1354 | 1431 |
| 185 | 22,5 | 1639 | 1730 |
| 240 | 27,4 | 2148 | 2287 |
Factory Overview
Packaging & Shipping
Frequently asked questions and answer ( Q:- A:- )
Q:- What is the primary application of the H07Z-U/R/K cable?
A:- It is used for conduit and fixed, protected installations, particularly in environments where fire, smoke emission, and toxic fumes create a potential threat.
Q:- What are the key safety features of this cable?
A:- It features low smoke zero halogen (LSOH) insulation, ensuring low emission of smoke and corrosive gases when affected by fire, passing the BS 4066-1 and BS 7622 tests.
Q:- What standards does the cable construction follow?
A:- The construction adheres to BS 7211 standards, and the conductor complies with BS 6360 (class 1, 2, or 5).
Q:- What type of conductor and insulation does it use?
A:- It uses copper wires with a Type EI 5, low smoke, zero halogen, thermosetting compound insulation.
Q:- What is the temperature range for this cable?
A:- The fixed temperature range is -40°C to +70°C, and the mobile temperature range is -5°C to +70°C.
Q:- What is the rated voltage and test voltage?
A:- The rated voltage is 450/750 V, and the test voltage is AC 50 Hz at 2500 V.
Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 10 times the cable diameter for diameters up to 10mm, and 15 times for larger sizes.
Q:- What is the maximum core temperature?
A:- The maximum core temperature in operation is 90°C.
Q:- What are the color coding options available?
A:- Available colors include black, red, blue, pink, grey, yellow, green, brown, white, violet, and orange, with green/yellow permitted for two-color combinations.
Q:- Is this cable RoHS and CE compliant?
A:- Yes, the product is both RoHS and CE compliant.