H07V-U/-R/-K PVC Single-Core Cable – VDE 0281-3 & HD 21.3 S3

The H07V-U/-R/-K cable delivers dependable electrical connections for internal wiring and protected installations. Constructed with flexible copper conductors and PVC insulation, it offers excellent flexibility and durability for switchboards, distribution systems, and lighting fixtures. Because it meets VDE 0281-3, HD 21.3 S3, and IEC 60227-3 standards and is CE/RoHS compliant, it provides a safe and reliable solution for installation in conduits, tubes, and under plaster.

Application
H07V-U/-R/-K cables provide reliable electrical connections for internal wiring of equipment and installations. Because they feature flexible PVC insulation, installers use them in switchboards and distribution systems. Furthermore, they are suitable for protected installation in lighting fixtures with a rated voltage up to 1000 V. Additionally, they perform reliably in signal and control circuits, on and under plaster, and in closed installation tubes or ducts. However, these single-core cables are not suited for direct installation in flatbed tubes or on ducted floors, and they are not approved for the internal wiring of household appliances.

Cable construction
This cable strictly adheres to VDE 0281-3, HD 21.3 S3, and IEC 60227-3 standards. It features copper wires according to VDE 0295 class 1, 2, or 5 (IEC 60228). The insulation uses a PVC compound type YI1 according to VDE 0207 part 4. Available colors include black, red, blue, pink, grey, yellow, green, brown, white, and violet. Two-color combinations are not permitted except for green/yellow. Furthermore, this product is both RoHS and CE compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to VDE 0295 and IEC 60228. The maximum core temperature is 70 °C in operation. It operates at a rated voltage of 450/750 V and undergoes a test voltage of AC 50 Hz at 2500 V. The temperature range is mobile -5 °C to +70 °C and fixed -30 °C to +70 °C. Installers must respect a minimum bending radius of 10 times the cable diameter for diameters up to 10mm, and 15 times for larger sizes. Furthermore, it passes the flame test class 5 according to VDE 0472 part 804 and IEC 60 332-1.

Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data H07V-U/-R/-K 450/750V

Nominal cross section Approx. outer diameter Copper weight Approx. cable weight
mm² mm kg/km kg/km
H07V-U
1.5 2,9 13,7 21
2.5 3,5 23 33
4.0 4,0 36 48
6.0 4,5 54 67
10 5,8 91 112
H07V-R
1.5 3,1 14,4 23
2.5 3,8 23 35
4.0 4,3 36 51
6.0 4,9 57 74
10 6,8 96 116
16 7,9 146 180
25 9,7 232 310
35 11,1 328 385
50 13,4 474 558
70 15,5 669 790
95 18,0 889 1000
120 19,5 1130 1460
150 22,0 1404 1600
185 24,4 1713 2000
240 27,8 2283 2500
H07V-K
1.5 3,1 14 22
2.5 3,8 24 34
4.0 4,4 38 50
6.0 5,4 57 73
10 6,8 96 116
16 7,9 146 180
25 9,7 232 310
35 11,1 328 385
50 13,4 474 558
70 15,5 669 790
95 18,0 889 1000
120 19,5 1130 1460
150 22,0 1404 1600
185 24,4 1713 2000
240 27,8 2283 2500

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the H07V-U/-R/-K cable?
A:- It is used for internal wiring of equipment and installations, including switchboards, distribution systems, and lighting fixtures up to 1000 V.

Q:- Where can this cable be installed?
A:- It is suitable for protected installation in signal and control circuits, on and under plaster, and in closed installation tubes or ducts, but not in flatbed tubes or on ducted floors.

Q:- What standards does the cable construction follow?
A:- The construction adheres to VDE 0281-3, HD 21.3 S3, and IEC 60227-3 standards, and the conductor complies with VDE 0295 and IEC 60228.

Q:- What type of conductor and insulation does it use?
A:- It uses copper wires (class 1, 2, or 5) with a PVC compound type YI1 insulation.

Q:- What is the temperature range for this cable?
A:- The fixed temperature range is -30°C to +70°C, and the mobile temperature range is -5°C to +70°C.

Q:- What is the rated voltage and test voltage?
A:- The rated voltage is 450/750 V, and the test voltage is AC 50 Hz at 2500 V.

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 10 times the cable diameter for diameters up to 10mm, and 15 times for larger sizes.

Q:- What is the maximum core temperature?
A:- The maximum core temperature in operation is 70°C.

Q:- What are the color coding options available?
A:- Available colors include black, red, blue, pink, grey, yellow, green, brown, white, and violet, with green/yellow permitted for two-color combinations.

Q:- Is this cable flame retardant?
A:- Yes, it passes the flame test class 5 according to VDE 0472 part 804 and IEC 60 332-1.

Reviews

There are no reviews yet.

Be the first to review “H07V-U/-R/-K PVC Single-Core Cable – VDE 0281-3 & HD 21.3 S3”

Your email address will not be published. Required fields are marked *

RELATED PRODUCTS