RE-2Y(St)YSWAY-fl PIMF Armoured Individually Screened Control Cable – EN 50288-7

The RE-2Y(St)YSWAY-fl PIMF cable delivers dependable data transmission for measuring and control appliances. Constructed with bare copper conductors, PE insulation, individually screened pairs (PIMF), an overall static screen, galvanized steel wire armour, and a flame retardant PVC outer sheath, it offers exceptional signal integrity and mechanical protection. Because it meets EN 50288-7 standards and is RoHS compliant, it provides a safe and reliable solution for fixed installations in dry, wet, and outdoor wall environments.

Application
RE-2Y(St)YSWAY-fl PIMF cables provide reliable data transfer for measuring and control appliances. Because of their individual and overall static screens, installers use them to protect circuits from external interfering signals. Furthermore, these cables are suitable for fixed installation in dry and wet premises, as well as for outdoor installation on the walls of buildings. Additionally, they are specifically designed for environments where the non-proliferation of flames is required.

Cable construction
This cable strictly adheres to EN 50288-7 standards. It features bare copper conductors with nominal areas of 0.5mm² and 0.75mm² (classes 2 or 5). The insulation uses a PE compound. Each wire is twisted to a pair with PIMF construction: a drain wire (0.6 mm, tinned Cu), an Al-PET foil, and a metal tape as the individual screen, with a wrapping of plastic foil. The PIMF pairs are stranded into layers. A wrapping screen of aluminum tape (coated with polyester and a tinned copper wire) provides overall shielding. An inner sheath of PVC compound provides bedding. The armour consists of galvanized steel wire for mechanical protection. Finally, a PVC compound flame retardant outer sheath (black or other color) protects the entire assembly. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C of max. 36.8 Ω/km (0.5 mm² class 2) and 25.0 Ω/km (0.75 mm² class 2), or max. 38.2 Ω/km (0.5 mm² class 5) and 25.5 Ω/km (0.75 mm² class 5). The mutual capacitance at 800 Hz is max. 100 nF/km. The insulation resistance is min. 5 GΩ.km. The capacitance unbalance at 800 Hz (K1 max) is 250 pF/250m. The test voltage is 50 Hz, 1 min for 1000V (wire-wire) and 1500V (wire-screen). The L/R ratio is max. 25 H/Ω. The operating voltage peak is 500V. The temperature range is mobile -5 °C to +50 °C and fixed -30 °C to +65 °C. The minimum bending radius is 10 x cable diameter. Furthermore, it passes the flame retardance test according to IEC 60332-3, class C.

Cable core construction
The pairs are arranged in layers: 1 pair (1st layer), 2 pairs (2nd layer), 4 pairs (3rd layer), 8 pairs (4th layer), 12 pairs (2nd layer), 16 pairs (3rd layer), 20 pairs (4th layer), and 24 pairs (4th layer).

Color coding
Clear color coding ensures safe and accurate wiring. Pair 1 uses black with sequential numbering imprint (a-wire) and white with sequential numbering imprint (b-wire). Pair 2 follows the same scheme.

Type codes
RE = data cable, 2Y = insulation of PE, (St) = static screen, Y-fl = sheath of PVC compound fire retardant, PIMF = screened pairs, SWA = galvanized steel wire armour.

Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data RE – 2Y(St)YSWAY-fl…

Number of pairs External diameter approx. Copper weight Cable weight approx.
1x2x0,5mm² PIMF class 2 mm kg/km kg/km
2 14,0 28 268
4 15,6 52 334
8 19,7 100 505
12 23,4 148 789
16 25,8 196 979
20 28,2 243 1078
24 29,9 291 1165
1x2x0,5mm² PIMF class 5
2 14,0 27 267
4 15,6 50 332
8 19,7 96 501
12 23,4 142 774
16 25,8 188 963
20 28,2 234 1060
24 29,9 279 1189

Construction data RE – 2Y(St)YSWAY-fl…

Number of pairs External diameter approx. Copper weight Cable weight approx.
1x2x0,75mm² PIMF class 2 mm kg/km kg/km
2 14,9 40 302
4 17 73 395
8 22,3 138 729
12 25,4 204 988
16 27,8 270 1076
20 30,9 336 1278
24 34,6 402 1674
1x2x0,75mm² PIMF class 5
2 14,9 38 300
4 17 69 391
8 22,3 131 722
12 25,4 194 889
16 27,8 256 1074
20 30,9 319 1214
24 34,6 381 1654

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the RE-2Y(St)YSWAY-fl PIMF cable?
A:- It is used for data transfer in measuring and control appliances, protecting circuits from external interfering signals in dry, wet, and outdoor wall installations.

Q:- What are the key features of the PIMF and SWA construction?
A:- PIMF provides individual pair screening with a drain wire and foil, while the SWA (galvanized steel wire armour) offers robust mechanical protection for harsh environments.

Q:- What standards does the cable construction follow?
A:- The construction adheres to EN 50288-7 standards.

Q:- What type of conductor and insulation does it use?
A:- It uses bare copper conductors with a PE compound insulation.

Q:- What is the temperature range for this cable?
A:- The fixed temperature range is -30°C to +65°C, and the mobile temperature range is -5°C to +50°C.

Q:- What is the mutual capacitance of this cable?
A:- The mutual capacitance at 800 Hz is max. 100 nF/km.

Q:- What is the test voltage for this cable?
A:- The test voltage is 50 Hz, 1 min for 1000V (wire-wire) and 1500V (wire-screen).

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 10 times the cable diameter.

Q:- What do the type codes RE, 2Y, (St), Y-fl, PIMF, and SWA stand for?
A:- RE indicates a data cable, 2Y indicates PE insulation, (St) indicates a static screen, Y-fl indicates a flame retardant PVC sheath, PIMF indicates screened pairs, and SWA indicates galvanized steel wire armour.

Q:- How is the overall static screen constructed?
A:- The overall static screen consists of a wrapping of aluminum tape coated with polyester and one tinned copper wire.

Reviews

There are no reviews yet.

Be the first to review “RE-2Y(St)YSWAY-fl PIMF Armoured Individually Screened Control Cable – EN 50288-7”

Your email address will not be published. Required fields are marked *

RELATED PRODUCTS