RE-2Y(St)Y Instrumentation and Control Cable – BS 5308 Part 1

The RE-2Y(St)Y cable delivers dependable data transmission for computers and process control in industrial plants. Constructed with bare copper conductors, PE insulation, a static aluminum tape screen with a tinned copper wire, and a black PVC outer sheath, it offers exceptional signal integrity and interference protection. Because it meets BS 5308 Part 1 standards and is RoHS compliant, it provides a safe and reliable solution for fixed installations in dry, wet, and outdoor wall environments.

Application
RE-2Y(St)Y cables provide reliable data transmission for computers and process control in industrial plants. Because of their low operating capacity, installers use them for long-distance data transfer while maintaining signal integrity. Furthermore, the static screen protects the data from external interfering signals. Additionally, these cables are suitable for fixed installation in dry and wet premises, as well as for outdoor installation on the walls of buildings. However, using them for power installations and underground installation is not permitted.

Cable construction
This cable strictly adheres to BS 5308 part 1 standards. It features bare copper conductors according to BS 6360 with various nominal areas (0.5mm², 1.0mm², 1.5mm²) and classes. The insulation uses a PE type according to BS 6234. Each pair is twisted to a pair with pairs stranded into layers. A wrapping screen consists of several layers of plastic tapes of aluminum tape, one side coated with polyester, and one tinned copper wire (0.5mm²). Finally, a black PVC sheath according to BS 6746 protects the entire assembly. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C of max. 36.8 Ω/km for 0.5 mm², 18.4 Ω/km for 1.0 mm², and 12.3 Ω/km for 1.5 mm². The mutual capacitance at 800 Hz is max. 75 nF/km for 0.5 mm², 75 nF/km for 1.0 mm², and 85 nF/km for 1.5 mm². The insulation resistance is min. 5 GΩ.km. The capacitance unbalance at 800 Hz (K1 max) is 250 pF/250m. The test voltage is 50 Hz, 1 min for 1000V (wire-screen) and 1000V (wire-wire). The operating voltage peak is 300V. The temperature range is fixed -10 °C to +50 °C and mobile -40 °C to +65 °C. The minimum bending radius is 7.5 x cable diameter.

Cable core construction
The pairs are arranged in layers: 1 pair (1st layer), 2 pairs (2nd layer), 5 pairs (2(Grad)), 10 pairs (2nd layer), 15 pairs (3rd layer), 20 pairs (4th layer), etc.

Color coding
Clear color coding ensures safe and accurate wiring. The a-wire colors include white, orange, green, brown, grey, red, blue, black, yellow, and violet. The b-wire colors include blue, orange, green, brown, grey, red, black, yellow, violet, and pink.

Type codes
RE = control cable, 2Y = PE insulation, (St) = static screen, Y = PVC sheath, Lg = laid up in layers.

Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data RE – 2Y(St)Y…

Number of pairs External diameter approx. Copper weight Cable weight approx.
2×0,5 mm² /1class Lg mm kg/km kg/km
1 5,4 14 38
2 8,2 23 56
5 10,7 52 121
10 13,9 99 211
15 18,2 147 287
20 20,5 194 375
30 22,1 289 526
50 28,1 478 847
2×1,0 mm² /1class Lg
1 6,5 23 51
2 9,4 42 80
5 13,4 99 197
10 17,6 193 344
15 20,5 280 491
20 24,3 381 600
30 28,1 570 928
50 36,4 947 1547

Construction data RE – 2Y(St)Y…

Number of pairs External diameter approx. Copper weight Cable weight approx.
2×0,5 mm² /1class Lg mm kg/km kg/km
1 6,1 13 40
2 7,9 22 57
5 12,3 49 135
10 16,3 94 236
15 19,0 139 327
20 21,1 191 374
25 26,0 274 605
30 28,0 299 655
2×1,5 mm² /1class Lg
1 7,4 34 67
2 9,4 52 92
5 15,5 152 259
10 20,7 300 490
15 24,3 448 714
20 28,0 590 931
30 33,4 893 1354
50 42,7 1485 2211

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the RE-2Y(St)Y cable?
A:- It is used for computers and process control in industrial plants, especially for long-distance data transfer in dry, wet, and outdoor wall installations.

Q:- What are the key features of the screen?
A:- The wrapping screen consists of several layers of plastic tapes of aluminum tape coated with polyester and one tinned copper wire, protecting data from external interference.

Q:- What standards does the cable construction follow?
A:- The construction adheres to BS 5308 part 1 standards, the conductor complies with BS 6360, and the sheath follows BS 6746.

Q:- What type of conductor and insulation does it use?
A:- It uses bare copper conductors with PE insulation according to BS 6234.

Q:- What is the temperature range for this cable?
A:- The fixed temperature range is -10°C to +50°C, and the mobile temperature range is -40°C to +65°C.

Q:- What is the mutual capacitance of this cable?
A:- The mutual capacitance at 800 Hz is max. 75 nF/km for 0.5 mm² and 1.0 mm², and max. 85 nF/km for 1.5 mm².

Q:- What is the test voltage for this cable?
A:- The test voltage is 50 Hz, 1 min for 1000V (wire-screen and wire-wire).

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 7.5 times the cable diameter.

Q:- What is the operating voltage peak?
A:- The operating voltage peak is 300V.

Q:- What do the type codes RE, 2Y, (St), Y, and Lg stand for?
A:- RE indicates a control cable, 2Y indicates PE insulation, (St) indicates a static screen, Y indicates a PVC sheath, and Lg indicates laid up in layers.

Reviews

There are no reviews yet.

Be the first to review “RE-2Y(St)Y Instrumentation and Control Cable – BS 5308 Part 1”

Your email address will not be published. Required fields are marked *