RD-Y(St)Y Instrumentation and Control Cable – BS 5308 Part 2

The RD-Y(St)Y cable delivers dependable data transmission for measuring and control appliances. Constructed with bare copper conductors, PVC insulation, a static aluminum tape screen with a tinned copper wire, and a black PVC outer sheath, it offers exceptional signal integrity and interference protection. Because it meets BS 5308 Part 2 standards and is RoHS compliant, it provides a safe and reliable solution for fixed installations in dry, wet, and outdoor wall environments.

Application
RD-Y(St)Y cables provide reliable data transfer for measuring and control appliances. Because of their static screen, installers use them to protect circuits from external interfering signals. Furthermore, these cables are suitable for fixed installation in dry and wet premises, as well as for outdoor installation on the walls of buildings. However, using them for power installations and underground installation is not permitted.

Cable construction
This cable strictly adheres to BS 5308 part 2 standards. It features bare copper conductors according to BS 6360 with various nominal areas (0.5mm², 0.75mm², 1.5mm²) and classes. The insulation uses a PVC type TI1 according to BS 6746. Each pair is twisted, with a-wire colors paired with b-wires. The pairs are stranded into layers. A wrapping screen consists of several layers of plastic tapes of aluminum tape, one side coated with polyester and one tinned copper wire (0.5mm²). Finally, a black PVC compound type TM1 sheath according to BS 6746 protects the entire assembly. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C of max. 39.7 Ω/km for 0.5 mm², 26.5 Ω/km for 0.75 mm², and 12.3 Ω/km for 1.5 mm². The mutual capacitance at 800 Hz is max. 250 nF/m. The insulation resistance is min. 100 MΩ.km. The capacitance unbalance at 800 Hz (K1 max) is 250 pF/250m. The test voltage is 50 Hz, 1 min for 1000V (wire-wire and wire-screen). The operating voltage peak is 300V. The temperature range is fixed -5 °C to +50 °C and mobile -40 °C to +80 °C. The minimum bending radius is 7.5 x cable diameter.

Cable core construction
The pairs are arranged in layers: 1 pair (1st layer), 2 pairs (2nd layer), 5 pairs (2(Grad)), 10 pairs (2nd layer), 15 pairs (3rd layer), 20 pairs (4th layer), etc.

Color coding
Clear color coding ensures safe and accurate wiring. The a-wire colors include white, orange, green, brown, grey, red, blue, black, yellow, and violet. The b-wire colors include blue, orange, green, brown, grey, red, black, yellow, violet, and pink.

Type codes
RD = control cable, Y = insulation or sheath of PVC, (St) = static screen, Lg = laid up in layers.

Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data RD-Y(St)Y…

Number of pairs External diameter approx. Copper weight Cable weight approx.
2×0,5mm² /5class Lg mm kg/km kg/km
1 6,1 13 42
2 7,8 22 63
5 12,3 49 143
10 16,3 94 262
15 18,9 139 356
20 21,4 184 465
2×0,75mm² /5class Lg
1 6,5 19 50
2 7,5 34 72
5 13,2 78 171
10 17,6 151 306
15 20,5 224 430
20 22,3 298 569
2×1,5mm² /1class Lg
1 7,4 34 71
2 8,8 64 112
5 15,5 152 269
10 20,7 300 491
15 24,3 448 714
20 27,6 597 920

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the RD-Y(St)Y cable?
A:- It is used for data transfer in measuring and control appliances, protecting circuits from external interfering signals in dry, wet, and outdoor wall installations.

Q:- What are the key features of the screen?
A:- The wrapping screen consists of several layers of plastic tapes of aluminum tape coated with polyester and one tinned copper wire, providing static protection.

Q:- What standards does the cable construction follow?
A:- The construction adheres to BS 5308 part 2 standards, the conductor complies with BS 6360, and the insulation and sheath follow BS 6746.

Q:- What type of conductor and insulation does it use?
A:- It uses bare copper conductors with PVC type TI1 insulation.

Q:- What is the temperature range for this cable?
A:- The fixed temperature range is -5°C to +50°C, and the mobile temperature range is -40°C to +80°C.

Q:- What is the mutual capacitance of this cable?
A:- The mutual capacitance at 800 Hz is max. 250 nF/m.

Q:- What is the test voltage for this cable?
A:- The test voltage is 50 Hz, 1 min for 1000V (wire-wire and wire-screen).

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 7.5 times the cable diameter.

Q:- What is the operating voltage peak?
A:- The operating voltage peak is 300V.

Q:- What do the type codes RD, Y, (St), and Lg stand for?
A:- RD indicates a control cable, Y indicates PVC insulation or sheath, (St) indicates a static screen, and Lg indicates laid up in layers.

Reviews

There are no reviews yet.

Be the first to review “RD-Y(St)Y Instrumentation and Control Cable – BS 5308 Part 2”

Your email address will not be published. Required fields are marked *

RELATED PRODUCTS