2XYRY-O/J & A2XYRY-O/J 0.6/1 kV XLPE Armoured Power Cable – IEC 60502-1
The 2XYRY-O/J and A2XYRY-O/J 0.6/1 kV cables deliver dependable power distribution for industrial installations and urban networks. Constructed with solid or stranded Cu/Al conductors, XLPE insulation, and steel wire armour, they offer excellent thermal and mechanical protection. Because they meet IEC 60502-1 standards and are RoHS compliant, they provide a safe and reliable solution for cable ducts, tunnels, and outdoor installations under shelters.
Application
2XYRY-O/J and A2XYRY-O/J cables provide reliable power and control distribution for industrial installations and urban networks. These cables operate with a nominal voltage Uo/U of 0.6/1 kV. Because of their robust design, installers use them for fixed assembly in lines with unlimited difference levels. Furthermore, they function well in cable ducts, tunnels, and conduits. Additionally, they perform reliably on shelves and grilles outdoors under shelters. Consequently, they deliver consistent performance in demanding infrastructure environments.
Cable construction
This cable strictly adheres to IEC 60502-1 standards. It features solid or multi-strand aluminum or copper wires (class 1 or 2) that comply with IEC 60228. The insulation uses an XLPE compound for superior thermal resistance. Additionally, a PVC compound forms the inner sheath, and the armour consists of steel wires twisted concentrically. Finally, a PVC compound type ST2 sheath protects the entire assembly. Furthermore, this product is RoHS compliant.
Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to IEC 60228 class 1 or 2. The maximum conductor temperature reaches 90 °C for continuous operation. During an overload, it can withstand 130 °C for 100% per year max. In a short circuit, it withstands 250 °C for a maximum of 5 seconds. It operates at a nominal voltage of 0.6/1 kV, while the highest system voltage is 1.2 kV. Test voltage AC is applied for 5 minutes at 3.5 kV between cores and between core and screen. Installers must respect a minimum bending radius of 15 times the cable diameter. The laying temperature should not fall below 0 °C, and the explosion temperature ranges from -30 to 50 °C.
Color coding
Clear color coding ensures safe and accurate wiring. Double core cables feature blue and brown, or yellow-green and black. Multi-core configurations include specific color sequences for easy identification.
Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.
Construction data 2XYRY-O/J, A2XYRY-O/J 0.6/1 kV
| Number of conductors and nominal cross section | Thickness of insulation | Thickness of sheath | Cable diameter approx. | 2XYRY-O/J Mass of Cu approx. | 2XYRY-O/J Cable weight approx. | A2XYRY-O/J Mass of Al approx. | A2XYRY-O/J Cable weight approx. |
|---|---|---|---|---|---|---|---|
| N x mm² | mm | mm | mm | kg/km | kg/km | kg/km | kg/km |
| 2 x 2,5 m | 0,7 | 1,8 | 14,1 | 46 | 421 | 14 | 388 |
| 2 x 4 m | 0,7 | 1,8 | 15,2 | 75 | 500 | 23 | 448 |
| 2 x 6 m | 0,7 | 1,8 | 16,1 | 88 | 563 | 29 | 512 |
| 2 x 10 m | 0,7 | 1,8 | 18,8 | 188 | 868 | 56 | 723 |
| 2 x 16 m | 0,7 | 1,8 | 21,9 | 266 | 1150 | 89 | 931 |
| 2 x 25 m | 0,9 | 1,8 | 24,9 | 485 | 1584 | 140 | 1235 |
| 2 x 35 m | 0,9 | 1,9 | 26,2 | 645 | 2076 | 188 | 1730 |
| 2 x 50 m | 1,0 | 2,1 | 29,2 | 908 | 2376 | 240 | 1727 |
| 3 x 1,5 m | 0,7 | 1,8 | 16,5 | 78 | 468 | 17 | 417 |
| 3 x 2,5 m | 0,7 | 1,8 | 16,5 | 70 | 619 | 21 | 570 |
| 3 x 4 m | 0,7 | 1,8 | 17,5 | 70 | 719 | 38 | 658 |
| 3 x 6 m | 0,7 | 1,8 | 18,8 | 168 | 769 | 51 | 676 |
| 3 x 10 m | 0,7 | 1,8 | 19,8 | 282 | 987 | 85 | 785 |
| 3 x 16 m | 0,7 | 1,8 | 21,3 | 447 | 1254 | 135 | 915 |
| 3 x 25 m | 0,9 | 1,8 | 27,8 | 478 | 1830 | 210 | 1236 |
| 3 x 35 m | 0,9 | 1,8 | 27,8 | 1010 | 2300 | 290 | 1593 |
| 3 x 70 m | 1,0 | 1,9 | 33,8 | 1353 | 2801 | 385 | 1914 |
| 3 x 95 m | 1,1 | 2,1 | 35,3 | 1968 | 3330 | 517 | 2237 |
| 4 x 2,5 m | 0,7 | 1,8 | 16,6 | 93 | 509 | 26 | 467 |
| 4 x 4 m | 0,7 | 1,8 | 17,5 | 149 | 690 | 42 | 606 |
| 4 x 6 m | 0,7 | 1,8 | 18,8 | 230 | 820 | 58 | 754 |
| 4 x 10 m | 0,7 | 1,8 | 21,2 | 176 | 1578 | 112 | 1309 |
| 4 x 16 m | 0,7 | 1,8 | 23,5 | 595 | 2076 | 180 | 1832 |
| 4 x 25 m | 0,9 | 1,9 | 27,5 | 570 | 2620 | 290 | 2030 |
| 4 x 33 m | 1,0 | 2,1 | 30,3 | 846 | 3701 | 390 | 2737 |
| 4×50 m | 1,0 | 2,1 | 34,0 | 1817 | 3301 | 520 | 2225 |
| 4×70 m | 1,1 | 2,1 | 38,6 | 2672 | 4015 | 720 | 2940 |
| 4×95 m | 1,6 | 2,1 | 43,0 | 3843 | 5075 | 1050 | 3430 |
| 4×120 sm | 1,6 | 2,2 | 47,5 | 4367 | 7626 | 1340 | 4346 |
| 4×150 sm | 1,8 | 2,4 | 51,8 | 5810 | 9141 | 1690 | 5094 |
| 4×185 sm | 2,0 | 2,5 | 56,2 | 6960 | 10028 | 2050 | 5496 |
| 4×240 sm | 2,2 | 2,6 | 62,3 | 9371 | 12861 | 2720 | 7207 |
| 7 x 1,5 m | 0,7 | 1,8 | 17,0 | 9308 | 980 | 2720 | 789 |
| 7 x 2,5 m | 0,7 | 1,8 | 19,1 | 109 | 1167 | 49 | 762 |
| 10 x 1,5 m | 0,7 | 1,8 | 20,4 | 165 | 1193 | 51 | 717 |
| 12 x 1,5 m | 0,7 | 1,8 | 20,4 | 165 | 2277 | 51 | 1179 |
| 19 x 2,5 m | 0,7 | 1,8 | 25,6 | 435 | 2277 | 133 | 1972 |
Factory Overview

Packaging & Shipping



Reviews
There are no reviews yet.