2XYRaY & A2XYRaY 0.6/1 kV XLPE Armoured Power Cable – IEC 60502-1

The 2XYRaY and A2XYRaY 0.6/1 kV cables deliver dependable power distribution for industrial installations and urban networks. Constructed with solid or stranded Cu/Al conductors, XLPE insulation, and aluminum wire armour, they offer excellent thermal and mechanical protection. Because they meet IEC 60502-1 standards and are RoHS compliant, they provide a safe and reliable solution for cable ducts, tunnels, and outdoor installations under shelters.

Application
2XYRaY and A2XYRaY cables provide reliable power and control distribution for industrial installations and urban networks. These cables operate with a nominal voltage of 0.6/1 kV. Because of their robust design, installers use them for fixed assembly in cable ducts, tunnels, and conduits. Furthermore, they function well on shelves and grilles outdoors under shelters, particularly in locations with unlimited difference levels. Consequently, they deliver consistent performance in demanding infrastructure environments.

Cable construction
This cable strictly adheres to IEC 60502-1 standards. It features solid or multi-strand aluminum or copper wires (class 1 or 2) that comply with IEC 60228. The insulation uses an XLPE compound for superior thermal resistance. Additionally, a PVC compound forms the inner sheath, and the armour consists of concentrically twisted aluminum wires. Finally, a PVC compound type ST2 sheath protects the entire assembly. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to IEC 60228 class 1 or 2. The maximum conductor temperature reaches 90 °C for continuous operation. During an overload, it can withstand 130 °C for 100% per year max. In a short circuit, it withstands 250 °C for a maximum of 5 seconds. It operates at a nominal voltage of 0.6/1 kV, while the highest system voltage is 1.2 kV. Test voltage AC is applied for 5 minutes at 3.5 kV between cores and between core and screen. Installers must respect a minimum bending radius of 15 times the cable diameter. The laying temperature should not fall below 0 °C, and the explosion temperature ranges from -30 to 50 °C.

Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data 2XYRaY, A2XYRaY 0.6/1 kV

Number of conductors and nominal cross section Thickness of insulation Thickness of sheath Cable diameter approx. 2XYRaY Cu approx. 2XYRaY Cable weight approx. A2XYRaY Al approx. A2XYRaY Cable weight approx.
N x mm² mm mm mm kg/km kg/km kg/km kg/km
1×25 rm 0,9 1,8 15,3 220 532 68 370
1×35 rm 0,9 1,8 16,3 325 657 90 425
1×50 rm 1,0 1,8 17,4 438 853 127 498
1×70 rm 1,1 1,8 18,7 648 1073 190 611
1×95 rm 1,1 1,8 20,5 885 1417 260 785
1×120 rm 1,2 1,8 22,1 1120 1707 305 866
1×150 rm 1,4 1,8 24,3 1378 2028 405 1046
1×185 rm 1,6 1,9 26,4 1700 2643 510 1371
1×240 rm 1,7 2,0 29,4 2327 3355 665 1656
1×300 rm 1,8 2,1 31,2 2857 4118 830 2010
1×350 rm 1,8 2,1 34,5 3357 4363 990 2314

Note: Other core configuration and special constructions manufactured upon request.

Factory Overview


Packaging & Shipping


Frequently asked questions and answer

Q:- What is the primary application of the 2XYRaY and A2XYRaY cables?
A:- They are used in electrical installations with nominal voltage 0.6/1 kV for fixed assembly in lines with unlimited difference levels, in cable ducts, tunnels, conduits, and on shelves and grilles outdoors under shelters.

Q:- What standards does the cable construction follow?
A:- The construction adheres to IEC 60502-1 standards, and the conductor complies with IEC 60228.

Q:- What type of conductor and insulation does it use?
A:- It uses solid or multi-strand Al or Cu wires class 1 or 2 for the conductor and XLPE compound for insulation.

Q:- What kind of armour protects this cable?
A:- The cable features an armour made of concentrically twisted aluminum wires.

Q:- What is the nominal voltage and highest system voltage?
A:- The nominal voltage Uo/U is 0.6/1 kV, and the highest system voltage is 1.2 kV.

Q:- What are the maximum continuous and short circuit temperatures?
A:- The maximum conductor temperature is 90°C for continuous operation, and it can withstand a short circuit temperature of 250°C for a maximum of 5 seconds.

Q:- What is the overload temperature capacity?
A:- It can withstand an overload temperature of 130°C for 100% per year maximum.

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 15 times the cable diameter (15x D cable).

Q:- What are the temperature limits for laying and explosion?
A:- The laying temperature should be no less than 0°C, and the explosion temperature range is -30 to 50°C.

Q:- What type of outer sheath protects the cable?
A:- A PVC compound type ST2 sheath protects the entire cable assembly.

Reviews

There are no reviews yet.

Be the first to review “2XYRaY & A2XYRaY 0.6/1 kV XLPE Armoured Power Cable – IEC 60502-1”

Your email address will not be published. Required fields are marked *