AGKABEL Instrumentation B50 ESCS – Individual & Overall Screened
High-performance instrumentation cable designed for data transmission, data acquisition, entry control, and time recording systems. Features Copper 0.5mm² (7/0.3mm) conductors, PVC V-90HT White/Black numbered insulation, Aluminium/Polyester tape screen with Tinned Copper Drain Wire, and a Flame Retardant PVC Black sheath. Compliant with AS/NZS 1125, AS/ACIF S008, and AS/NZS 3808. Max operating temperature: 75°C. Available in 2 to 24 pairs.
AGKABEL GRUPPE LIMITED presents the Instrumentation B50 ESCS Cable, engineered for reliable signal transmission in critical data and control applications. Featuring both individual and overall screening, this cable provides excellent protection against electromagnetic interference (EMI) and crosstalk. It is suitable for indoor and outdoor installation in ducts or rack cable trays, making it ideal for data acquisition, entry control, and time recording systems. The flame-retardant PVC sheath ensures safety in sensitive environments.
Construction & Standards
-
Standard: AS/NZS 1125, AS/ACIF S008, AS/NZS 3808
-
Voltage: 300/500V
-
Conductor: Copper 0.5mm² (7/0.3mm)
-
Insulation: PVC V-90HT White with number mark and Black with number mark
-
Screen: Aluminium/Polyester tape with 7/0.25mm Tinned Copper Drain Wire
-
Sheath: Flame Retardant PVC Black (Intrinsically Safe blue PVC Sheath)
-
Max. Operating Temperature: 75°C
-
Sheath Marking: Manufacture name (trademark) and type, Production year/week or batch number, Metre-marked
Application
Suitable for data transmission, operating data acquisition, entry control and time recording system. Indoor and outdoor installation in duct or rack cable tray.
Technical Specifications Table
| Number of Pairs | No. of strands | Insulation Thickness (mm) | Drain Wire No. of strands | Overall Diameter (mm) | Minimum installed bending radius (mm) | Maximum pulling tension kN | Approx. Weight (Kg/km) |
|---|---|---|---|---|---|---|---|
| 2 | 7/0.3mm | 0.4 | 7/0.25mmTC | 6.9 | 70 | 0.23 | 60 |
| 4 | 7/0.3mm | 0.4 | 7/0.25mmTC | 9 | 90 | 0.42 | 100 |
| 6 | 7/0.3mm | 0.4 | 7/0.25mmTC | 10.7 | 110 | 0.61 | 140 |
| 8 | 7/0.3mm | 0.4 | 7/0.25mmTC | 12.2 | 120 | 0.79 | 180 |
| 10 | 7/0.3mm | 0.4 | 7/0.25mmTC | 13.5 | 130 | 0.98 | 220 |
| 12 | 7/0.3mm | 0.4 | 7/0.25mmTC | 14.7 | 150 | 1.2 | 250 |
| 16 | 7/0.3mm | 0.4 | 7/0.25mmTC | 16.9 | 170 | 1.5 | 330 |
| 20 | 7/0.3mm | 0.4 | 7/0.25mmTC | 18.7 | 190 | 1.9 | 420 |
| 24 | 7/0.3mm | 0.4 | 7/0.25mmTC | 20.4 | 200 | 2.3 | 490 |
Factory Overview

Packaging & Shipping


❓ Frequently Asked Questions (FAQ)
1. What are the primary applications for this cable?
It is suitable for data transmission, operating data acquisition, entry control, and time recording systems. It can be installed indoors and outdoors in ducts or rack cable trays.
2. What is the maximum operating temperature?
The maximum operating temperature is 75°C.
3. What materials are used for the conductor and insulation?
The conductor is Copper 0.5mm² (7/0.3mm). The insulation is PVC V-90HT (White with number mark and Black with number mark).
4. What type of screening does this cable have?
It features individual and overall screening using Aluminium/Polyester tape with a 7/0.25mm Tinned Copper Drain Wire.
5. What is the voltage rating of this cable?
The voltage rating is 300/500V.
6. What standards does this cable comply with?
It complies with AS/NZS 1125, AS/ACIF S008, and AS/NZS 3808.
7. What sizes and pair configurations are available?
Available in 2 to 24 pairs, all with 0.5mm² conductors.
8. What is the benefit of individual and overall screening?
Individual screening protects each pair from crosstalk, while overall screening protects the entire cable from external electromagnetic interference (EMI) , ensuring clean signal transmission.