TPJPBP Jelly Filled Armoured Local Network Communication Cable (x2x0.4 to x2x0.7)

This jelly-filled armoured communication cable is engineered for PABX systems and signal transmission in conduits and all types of grounds. It features a bare copper conductor with PE insulation and an aluminium tape screen for excellent interference protection. The petroleum jelly filling prevents moisture penetration into the cable core, while two steel tapes provide robust mechanical protection. Available in various configurations, it is strictly designed for signal transmission and not for power installations.

These jelly-filled armoured communication cables are specifically used as connecting cables in local networks and PABX systems for telephone purposes and for the transmission of signals. Because the filling of petroleum jelly does not permit moisture penetration into the cable core, they are exceptionally reliable for long-term underground infrastructure projects. Furthermore, they are suitable for laying in conduits and in all types of grounds, making them highly versatile for outdoor network deployments. However, it should be noted that the use of these cables for power installations is explicitly not permitted, ensuring they remain dedicated to signal transmission applications.

The cable structure features a bare copper conductor with diameters of 0.4 mm, 0.5 mm, 0.6 mm, or 0.7 mm, which is insulated with PE insulation type TY2, according to VDE 0207 part 2. Four wires are twisted into a quad, and 5 quads are twisted to a basic unit with petroleum jelly. A minimum of one layer of paper tape and an aluminium tape with a thickness of no less than 0.06mm, coated with copolymer on both sides, are applied for wrapping and screening. For mechanical protection, two steel tapes with a thickness of 0.3mm are applied. Finally, the assembly is protected by a PE low density protective sheath containing 2.5% carbon black.

Technical Data & Construction Overview:

  • Conductor diameter: 0.4 mm / 0.5 mm / 0.6 mm / 0.7 mm

  • Conductor resistance at 20°C-max: 150 Ω/km / 95 Ω/km / 65 Ω/km / 48 Ω/km

  • Insulation resistance – min: 5 GΩ x km

  • Mutual capacitance at 800Hz-nom: 55 nF/km

  • Capacitance unbalances at 800Hz-max: K1: 980 pF/500m; Ke: 1,500 pF/500m; K9-K12: 50% of all values; K9-K12: 300 pF/500m; 20% of all values; 200 pF/500m

  • Test voltage 50Hz, 2 min: Wire-wire 500V / Wire-screen 2000V

  • Operating voltage peak value: Cables with cores 0.4 and 0.5mm: 150V; Cables with cores 0.6 and 0.7mm: 220V

  • Temperature range: Laying and installing -10°C up to +60°C; Exploitation and storage -40°C up to +60°C

  • Bending radius, min. approx.: 10 x cable diameter

Cable core construction

Number of pairs Number of quads Number of units in the layers
5×4 (1st layer) 25×4 (2nd layer)
6 3 3-quads
10 5 5
20 10 2
30 15 5
50 25 5 1
70 35 5 2
100 50 3 7
150 75 3
200 100 4

Construction data TPJPBP…

Number of pairs Outer diameter approx. mm Copper weight kg/km Cable weight approx. kg/km
2x2x0.4
6 12.6 15 231
10 13.3 24 283
20 14.2 49 403
30 17.1 73 612
50 19.6 174 718
70 22.4 174 743
100 25.8 360 1332
150 30.7 360 1913
200 35.8 492 1743
2x2x0.5
6 13.2 23 250
10 14.2 37 321
20 17.1 73 443
30 18.3 111 612
50 20.8 190 784
100 27.5 387 1013
150 30.6 592 1851
200 36.9 592 1846
2x2x0.6
6 16.4 32 393
10 16.4 54 352
30 22.4 183 716
50 22.4 260 701
70 31.5 380 1381
100 35.6 564 1782
2x2x0.7
6 15.8 44 351
10 16.5 70 352
30 22.2 201 644
50 29.8 266 1060
70 35.8 532 1683
100 41.5 768 2407

Type codes

  • T – telephone cable

  • J – petroleum jelly filling

  • P – polyethylene insulation

  • B – steel tape armour

  • P – polyethylene sheath

Factory Overview


Packaging & Shipping


Frequently asked questions and answer (Q:- A:-)

Q:- What is the primary application of the TPJPBP cable?
A:- It is used as connecting cables in local networks and PABX systems for telephone and signal transmission.
Q:- What is the benefit of the petroleum jelly filling?
A:- The jelly filling prevents moisture penetration into the cable core, protecting the cable in underground environments.
Q:- Where is this cable suitable for installation?
A:- It is suitable for laying in conduits and in all types of grounds.
Q:- Can this cable be used for power installations?
A:- No, the use of these cables for power installations is explicitly not permitted.
Q:- What conductor diameters are available for this cable?
A:- The cable is available with conductor diameters of 0.4 mm, 0.5 mm, 0.6 mm, and 0.7 mm.
Q:- How is the cable protected against mechanical damage?
A:- It is protected by two steel tapes with a thickness of 0.3mm.
Q:- How is the cable protected against electromagnetic interference?
A:- It features an aluminium tape with a thickness of no less than 0.06mm coated with copolymer on both sides.
Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is approximately 10 times the cable diameter.
Q:- What material is used for the outer sheath?
A:- The outer sheath is made of PE low density with 2.5% carbon black.
Q:- What is the temperature range for laying and installing?
A:- The laying and installing temperature range is -10°C up to +60°C.
Q:- What is the nominal mutual capacitance at 800 Hz?
A:- The nominal mutual capacitance is 55 nF/km.

Reviews

There are no reviews yet.

Be the first to review “TPJPBP Jelly Filled Armoured Local Network Communication Cable (x2x0.4 to x2x0.7)”

Your email address will not be published. Required fields are marked *