AGKABEL UL AWM Style 2464 Multi-Conductor Cable is a flexible, PVC-insulated and PVC-jacketed control and signal cable recognized under UL 758 (AWM) and commonly certified to CSA standards. Rated at 300V and 80°C, it is available with 2 to 12+ color-coded conductors in sizes from 28 AWG to 16 AWG. Standard constructions feature stranded copper conductors and a flexible PVC jacket, with UL VW-1 / CSA FT1 flame ratings. Shielded variants (foil or braid) are available for EMI protection. Ideal for internal wiring of electronic equipment, control panels, PLC systems, and RS-232/422/485 serial communication, it is the perfect solution for protected, low-voltage signal and control circuits. Not intended for continuous flexing or outdoor exposure.
AGKABEL T90 Nylon Sheath Cable / XHHW-2 – 600 Volts
Heavy-duty single-conductor cables designed for installation in conduit (raceways), cable trays, or as exposed wiring in dry or damp locations. Features a Soft Annealed Copper conductor, heat- and moisture-resistant Thermoplastic (PVC) insulation, and a tough Nylon sheath for added mechanical protection. Compliant with ASTM and CSA C22.2 No. 75. Max voltage rating: 600V. Available from AWG 14 to 4/0, and 250 kcmil to 1000 kcmil. Available in a variety of colors.
AGKABEL GRUPPE LIMITED presents the T90 Nylon Sheath Cable and XHHW-2, engineered for reliable power distribution in demanding environments. The T90 is primarily intended for installation in conduit (raceways) or as exposed wiring in dry or damp locations (maximum 600V). The XHHW-2 variant is widely used in conduit, cable trays, or other recognized raceways for service feeders and branch circuit wiring, as specified in the National Electrical Code (NEC).
These cables are manufactured with an annealed (soft) copper conductor and a tough, heat- and moisture-resistant thermoplastic polyvinyl chloride (PVC) insulation. The addition of a Nylon sheath provides excellent mechanical protection and low friction for easy pulling in conduits. Sizes AWG 14-19 through AWG 4/0 are manufactured using combination unilay stranding; all other stranded sizes use compressed stranding. Available in black, white, red, blue, green, yellow, brown, orange, and gray (some colors subject to economic order quantity).
Technical Data
-
Standard: ASTM, CSA C22.2 No. 75
-
Voltage: 600 Volts
-
Conductor: Soft annealed copper. #14-4/0AWG uses a compressed copper strand.
-
Insulation: Thermoplastic Insulation (PVC)
-
Sheath: Nylon Sheath
-
Application (T90): Primarily intended for installation in conduit (raceways) or as exposed wiring in dry or damp locations. Maximum voltage rating is 600 volts. Consult the Canadian Electrical Code, 2012 Edition.
-
Application (XHHW-2): Primarily used in conduit, Cable Tray or other recognized raceways for service feeders, and branch circuit wiring, as specified in the National Electrical Code.
Technical Specifications Table
| Conductor (AWG or kcmil) | No. of strands | Insulation Thickness (in) | Jacket Thickness (in) | Jacket Diameter (mils) | Max. DC Resistance at 20°C (Ohm/km) | Approx. weight (1000′ lbs) |
|---|---|---|---|---|---|---|
| 14* | 1 | 0.015 | 0.004 | 0.102 | 8.79 | 23 |
| 12* | 1 | 0.015 | 0.004 | 0.119 | 5.41 | 34 |
| 10* | 1 | 0.020 | 0.004 | 0.150 | 3.64 | 55 |
| 14* | 19 | 0.015 | 0.004 | 0.109 | 9.10 | 23 |
| 12* | 19 | 0.015 | 0.004 | 0.128 | 5.60 | 36 |
| 10* | 19 | 0.020 | 0.004 | 0.161 | 4.20 | 57 |
| 8 | 19 | 0.030 | 0.005 | 0.213 | 2.36 | 93 |
| 6 | 19 | 0.030 | 0.005 | 0.249 | 1.44 | 141 |
| 4 | 19 | 0.040 | 0.006 | 0.318 | 0.91 | 227 |
| 3 | 19 | 0.040 | 0.006 | 0.348 | 0.71 | 281 |
| 2 | 19 | 0.040 | 0.006 | 0.378 | 0.57 | 349 |
| 1 | 19 | 0.050 | 0.007 | 0.435 | 0.47 | 446 |
| 2/0 | 19 | 0.050 | 0.007 | 0.518 | 0.29 | 687 |
| 4/0 | 19 | 0.050 | 0.007 | 0.624 | 0.18 | 1068 |
(Note: * denotes compact or combination unilay stranded. Further dimensions available on request.)
Factory Overview
Packaging & Shipping


❓ Frequently Asked Questions (FAQ)
1. What are the primary applications for these cables?
-
T90: Primarily intended for installation in conduit (raceways) or as exposed wiring in dry or damp locations.
-
XHHW-2: Primarily used in conduit, cable trays, or other recognized raceways for service feeders and branch circuit wiring.
2. What is the purpose of the Nylon sheath?
The Nylon sheath provides excellent mechanical protection and reduces friction, making it easier to pull the cable through conduits.
3. What is the voltage rating and maximum temperature?
The maximum voltage rating for all intended applications is 600 volts. The thermoplastic insulation allows for a maximum conductor temperature of 90°C (in wet or dry locations).
4. What materials are used for the conductor and insulation?
The conductor is Soft Annealed Copper, and the insulation is Thermoplastic PVC.
5. What standards do these cables comply with?
They comply with ASTM and CSA C22.2 No. 75. The XHHW-2 variant is also recognized by the National Electrical Code (NEC).
6. What colors are available?
Available in black, white, red, blue, green, yellow, brown, orange, and gray (some colors subject to economic order quantity).