SAH-VO 0.6/1 kV Self-Supporting Overhead Cable – FN KI 02.003

The SAH-VO 0.6/1 kV cable delivers dependable power transmission and distribution for low voltage overhead networks. Constructed with aluminum conductors, XLPE insulation, and a self-supporting bundle design, it offers excellent performance for permanent suspension on facades and trees. Because it meets FN KI 02.003 standards, it provides a reliable solution for crossing forest areas without cutting.

Application
SAH-VO power cables provide reliable transmission, distribution, and supply of electrical power in low voltage networks. They operate efficiently at a nominal voltage of 0.6/1 kV. Because these self-supporting cables are designed for overhead lines, installers use them for permanent suspension on facades and trees. Furthermore, they allow crossing of forest areas without cutting and maintenance openings in the wood. Additionally, the suspension and support of the whole bundle is carried out by a supporting insulated neutral wire of aluminum or aluminum alloy.

Cable construction
This cable strictly adheres to FN KI 02.003-96 standards. It features Al stranded compacted or non-compacted phase (main) conductors according to FN KI 02.003. The neutral (supporting) N conductor uses Al or Al alloy. The additional lighting R conductor uses Al stranded compacted or non-compacted. The insulation uses XLPE with a minimum 2% carbon black content. The cable lay-up constructions are twisted into a bundle, which includes phase (main) insulated cores (M), neutral supporting insulated core (N), and one, two, or three additional reduced insulated cores for lighting (R). The color is black, and the marking is to FN KI 02.003.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains an operating temperature of 80 °C. The short-circuit temperature is 130 °C. It operates at a nominal voltage Uo/U of 0.6/1 kV, while the highest system voltage AC is not more than 1.2 kV. Test voltage is AC 4 kV for 5 minutes and DC 10 kV for 15 minutes. The minimum bending radius is 18 times the cable diameter. The minimum temperature of laying is no less than -10 °C, and the recommended installation temperature is 15 °C. Conductor resistance at 20 °C varies by size: 16-1.91 Ω/km, 25-1.20 Ω/km, 35-0.868 Ω/km, 50-0.641 Ω/km, 70-0.443 Ω/km, and 95-0.320 Ω/km. The supported neutral breaking strength minimum is 5.5 kN.

Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and current carrying capacity.

Construction data SAH-VO 0.6/1 kV

Construction, number and cross section Diameter of bundle approx. Mass approx. Cable weight approx. Allowed current in power supply networks Allowed current at short-circuit
N x mm² mm kg/km kg/km A kA
3×50/m+71.5/35/m 27 499 575 107 1,3
3×50/m+71.5/35+1×16/m 27 544 751 107 1,3
3×25/m+71.5/35+2×16/m 27 589 827 107 1,3
3×50/m+71.5/35 31 588 767 132 1,9
3×50/m+71.5/35+1×16/m 31 630 919 132 1,9
3×35/m+71.5/35+2×16/m 31 679 919 132 1,9
3×50/m+71.5/50 34 712 925 162 2,7
3×50/m+71.5/50+1×16/m 34 757 1000 162 2,7
3×50/m+71.5/50+2×16/m 34 802 1076 162 2,7
3×70/m+71.5/50 40 864 1099 205 3,8
3×70/m+71.5/50+1×16/m 40 909 1175 205 3,8
3×70/m+71.5/50+2×16/m 40 954 1250 205 3,8

Note: Other core configuration and special constructions manufactured upon request.

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the SAH-VO cable?
A:- It is used for transmission, distribution, and supply of electrical power in low voltage networks, specifically designed for overhead lines and permanent suspension on facades and trees.

Q:- What is the advantage of the self-supporting design?
A:- The design allows crossing of forest areas without cutting and maintenance openings in the wood, as the suspension and support are carried out by a supporting insulated neutral wire of aluminum or aluminum alloy.

Q:- What standards does the cable construction follow?
A:- The construction adheres to FN KI 02.003-96 standards.

Q:- What type of conductor and insulation does it use?
A:- It uses Al stranded compacted or non-compacted phase conductors, Al or Al alloy neutral conductor, and XLPE insulation with minimum 2% carbon black content.

Q:- What are the components of the cable bundle?
A:- The bundle includes phase (main) insulated cores (M), a neutral supporting insulated core (N), and one, two, or three additional reduced insulated cores for lighting (R).

Q:- What is the nominal voltage and highest system voltage?
A:- The nominal voltage Uo/U is 0.6/1 kV, and the highest system voltage AC is not more than 1.2 kV.

Q:- What are the operating and short-circuit temperatures?
A:- The operating temperature is 80°C, and the short-circuit temperature is 130°C.

Q:- What is the test voltage for this cable?
A:- Test voltage is AC 4 kV for 5 minutes, and DC is 10 kV for 15 minutes.

Q:- What is the minimum bending radius and laying temperature?
A:- The minimum bending radius is 18 times the cable diameter, and the minimum temperature of laying is no less than -10°C.

Q:- What is the supported neutral breaking strength minimum?
A:- The supported neutral breaking strength minimum is 5.5 kN.