RD-Y(St)Y & RE-2Y(St)Y PiMF Industrial Electronic Cables – DIN VDE 0815
The RD-Y(St)Y and RE-2Y(St)Y PiMF cables deliver dependable signal transmission for measurement and control technology. Constructed with copper conductors, PVC or PE insulation, static screens, and twisted pairs, they offer excellent protection against electrical interference and crosstalk. Because they meet DIN VDE 0815 standards, they provide a safe and reliable solution for control rooms, industrial plants, and power stations.
Application
RD-Y(St)Y and RE-2Y(St)Y PiMF cables provide reliable signal transmission for measurement and control technology. Because they feature static screens and twisted pairs, installers use them in control rooms of industrial plants and power stations. Furthermore, the static screen protects transmission circuits against outer electrical interferences, and the twisted pairs lead to good crosstalk attenuation values in a unit. Additionally, these cables serve for the transmission of analog and digital signals up to frequencies of approx. 10 kHz (Max-Termi-Point capable). Consequently, they deliver consistent performance for fixed installation in buildings.
Cable construction
These cables strictly adhere to DIN VDE 0815 standards. They feature copper conductors. The insulation uses PVC compounds for RD variants and PE for RE variants. A static screen (aluminum foil with a drain wire) provides protection against external interference. The outer sheath is made of PVC compound. The PiMF designation indicates that the pairs are individually screened (PIMF) for maximum crosstalk protection. A blue outer jacket is also available for intrinsically safe installations.
Technical Data
The cables deliver consistent performance under specific conditions. The temperature range is -5 °C to +50 °C for flexing applications and -30 °C to +70 °C for fixed installations. The test voltage is 2000 V (core/core) and 1000 V (core/screen).
Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.
RD-Y(St)Y / RD-Y(St)Yv / RD-Y(St)YY
| Part N° | N° of cores x cross-sec mm² | Outer diameter ca. mm | Copper weight kg/km | Weight ca. kg/km |
|---|---|---|---|---|
| 11301026 | 2X2X0,5 | 6,0 | 25,00 | 60,00 |
| 11301027 | 4X2X0,5 | 8,0 | 45,00 | 95,00 |
| 11301028 | 8X2X0,5 | 11,5 | 85,00 | 157,00 |
| 11301029 | 12X2X0,5 | 12,0 | 125,00 | 229,00 |
| 11301030 | 16X2X0,5 | 13,7 | 165,00 | 290,00 |
| 11301001 | 20X2X0,5 Bd | 15,0 | 205,00 | 380,00 |
| 11301002 | 24X2X0,5 Bd | 16,3 | 245,00 | 422,00 |
| 11301003 | 28X2X0,5 Bd | o. r. | 285,00 | 530,00 |
| 11301004 | 32X2X0,5 Bd | 22,0 | 325,00 | 535,00 |
| 11301005 | 36X2X0,5 Bd | o. r. | 365,00 | 640,00 |
| 11301006 | 40X2X0,5 Bd | 21,8 | 405,00 | 700,00 |
| 11301007 | 44X2X0,5 Bd | o. r. | 445,00 | 760,00 |
| 11301008 | 48X2X0,5 Bd | 23,0 | 485,00 | 796,00 |
| 11301009 | 52X2X0,5 Bd | o. r. | 525,00 | 910,00 |
| 11301010 | 56X2X0,5 Bd | o. r. | 565,00 | 975,00 |
| 11301011 | 60X2X0,5 Bd | o. r. | 605,00 | 1.045,00 |
| 11301012 | 64X2X0,5 Bd | o. r. | 645,00 | 1.110,00 |
| 11301013 | 80X2X0,5 Bd | 28,8 | 805,00 | 1.340,00 |
| 11301014 | 96X2X0,5 Bd | 30,5 | 965,00 | 1.500,00 |
| 11301015 | 2X2X1 Bd | 10,0 | 51,00 | 120,00 |
| 11301016 | 4X2X1 Bd | 11,0 | 91,00 | 160,00 |
| 11301017 | 8X2X1 Bd | 15,0 | 171,00 | 310,00 |
| 11301018 | 12X2X1 Bd | 17,5 | 252,00 | 420,00 |
| 11301019 | 16X2X1 Bd | 20,5 | 332,00 | 560,00 |
| 11301020 | 20X2X1 Bd | 22,5 | 413,00 | 670,00 |
| 11301021 | 24X2X1 Bd | 24,5 | 493,00 | 810,00 |
| 11301022 | 32X2X1 Bd | 27,5 | 654,00 | 1.040,00 |
| 11301023 | 40X2X1 Bd | 31,0 | 816,00 | 1.290,00 |
| 11301024 | 48X2X1 Bd | 33,5 | 977,00 | 1.520,00 |
| 11301025 | 80X2X1 Bd | 42,0 | 1.617,00 | 2.440,00 |
| 11311001 | 2X2X0,5 | 9,0 | 25,00 | 95,00 |
| 11311002 | 8X2X0,5 | 13,0 | 85,00 | 202,00 |
RD-Y(St)YY / RE-2Y(St)Y / RE-2Y(St)Yv / RE-2Y(St)Yv PiMF
| Part N° | N° of cores x cross-sec mm² | Outer diameter ca. mm | Copper weight kg/km | Weight ca. kg/km |
|---|---|---|---|---|
| 11302001 | 2X2X0,5 Bd | 6,0 | 25,00 | 55,00 |
| 11302003 | 4X2X0,5 Bd | 8,0 | 45,00 | 91,00 |
| 11302005 | 8X2X0,5 Bd | 11,5 | 85,00 | 158,00 |
| 11302007 | 12X2X0,5 Bd | 12,0 | 125,00 | 210,00 |
| 11302009 | 16X2X0,5 Bd | 13,7 | 165,00 | 280,00 |
| 11302011 | 20X2X0,5 Bd | 15,0 | 205,00 | 340,00 |
| 11302013 | 24X2X0,5 Bd | 16,3 | 245,00 | 392,00 |
| 11302015 | 28X2X0,5 Bd | 18,2 | 285,00 | 425,00 |
| 11302017 | 32X2X0,5 Bd | 20,5 | 325,00 | 453,00 |
| 11302019 | 36X2X0,5 Bd | 21,8 | 365,00 | 510,00 |
| 11302021 | 40X2X0,5 Bd | 21,8 | 405,00 | 640,00 |
| 11302023 | 44X2X0,5 Bd | 22,5 | 445,00 | 690,00 |
| 11302025 | 48X2X0,5 Bd | 23,0 | 485,00 | 750,00 |
| 11302027 | 52X2X0,5 Bd | 23,8 | 525,00 | 795,00 |
| 11302029 | 56X2X0,5 Bd | 24,5 | 565,00 | 845,00 |
| 11302031 | 60X2X0,5 Bd | 25,4 | 605,00 | 899,00 |
| 11302033 | 64X2X0,5 Bd | 26,5 | 645,00 | 959,00 |
| 11302035 | 80X2X0,5 Bd | 28,8 | 805,00 | 1.200,00 |
| 11302037 | 96X2X0,5 Bd | 30,5 | 965,00 | 1.570,00 |
| 11305001 | 1x2x0,5 | 8,2 | 15,00 | 80,00 |
| 11305026 | 2x2x0,5 | 10,2 | 30,00 | 122,00 |
| 11305018 | 4x2x0,5 | 10,8 | 50,00 | 135,00 |
| 11305043 | 6x2x0,5 | 12,6 | 70,00 | 190,00 |
| 11305027 | 8x2x0,5 | 13,3 | 90,00 | 200,00 |
| 11305028 | 10x2x0,5 | 14,4 | 110,00 | 225,00 |
| 11305029 | 12x2x0,5 | 15,0 | 130,00 | 260,00 |
| 11305030 | 16x2x0,5 | 16,8 | 170,00 | 320,00 |
| 11305031 | 20x2x0,5 | 18,7 | 210,00 | 380,00 |
| 11305032 | 24x2x0,5 | 20,5 | 250,00 | 465,00 |
| 11305033 | 36x2x0,5 | 24,3 | 370,00 | 650,00 |
| 11305034 | 48x2x0,5 | 27,5 | 490,00 | 840,00 |
| 11305042 | 2x2x0,75 | 11,5 | 31,50 | 140,00 |
| 11305035 | 1x2x1,3 | 10,0 | 34,00 | 87,00 |
| 11305036 | 2x2x1,3 | 11,7 | 62,00 | 61,00 |
| 11305037 | 4x2x1,3 | 13,5 | 114,00 | 230,00 |
| 11305038 | 8x2x1,3 | 17,5 | 218,00 | 343,00 |
| 11305039 | 12x2x1,3 | 19,3 | 322,00 | 515,00 |
| 11305040 | 16x2x1,3 | 22,0 | 426,00 | 656,00 |
| 11305041 | 24x2x1,3 | 26,5 | 684,00 | 952,00 |
| 11305042 | 1x3x1,3 | 9,7 | 44,00 | 116,00 |
| 11307001 | 1x2x0,5 | 7,3 | 15,00 | 60,00 |
| 11307007 | 2x2x0,5 | 9,8 | 30,00 | 110,00 |
| 11307008 | 4x2x0,5 | 11,5 | 50,00 | 150,00 |
| 11307009 | 8x2x0,5 | 15,0 | 90,00 | 191,00 |
| 11307028 | 20x2x0,5 | 18,5 | 210,00 | 385,00 |
| 11307029 | 24x2x0,5 | 20,2 | 250,00 | 468,00 |
| 11307010 | 1x2x0,75 | 7,7 | 25,00 | 70,00 |
| 11307027 | 2x2x0,75 | 10,6 | 35,00 | 123,00 |
| 11307011 | 4x2x0,75 | 11,8 | 70,00 | 170,00 |
| 11307020 | 6x2x0,75 | 14,5 | 92,00 | 187,00 |
| 11307025 | 8x2x0,75 | 14,6 | 125,00 | 258,00 |
| 11307012 | 12x2x0,75 | 16,9 | 190,00 | 355,00 |
| 11307030 | 50x2x0,75 | 28,0 | 710,00 | 1.200,00 |
| 11307015 | 1x3x1,3 | 7,7 | 44,00 | 66,00 |
| 11307014 | 4x2x1,3 | 13,3 | 114,00 | 230,00 |
| 11307013 | 8x2x1,3 | 16,8 | 218,00 | 375,00 |
| 11307019 | 12x2x1,3 | 20,5 | 322,00 | 488,00 |
| 11307021 | 24x2x1,3 | 29,4 | 697,00 | 1.104,00 |
| 11307017 | 48x2x1,3 | 34,2 | 1.368,00 | 1.834,00 |
Factory Overview
Packaging & Shipping
Frequently asked questions and answer ( Q:- A:- )
Q:- What is the primary application of these instrumentation cables?
A:- They are used in measurement and control technology, particularly in control rooms of industrial plants and power stations.
Q:- What is the function of the static screen and twisted pairs?
A:- The static screen protects against outer electrical interferences, while the twisted pairs lead to good crosstalk attenuation values.
Q:- What standards do these cables comply with?
A:- They comply with DIN VDE 0815 standards.
Q:- What is the maximum frequency for signal transmission?
A:- They are suitable for transmitting analog and digital signals at frequencies up to approx. 10 kHz (Max-Termi-Point capable).
Q:- What does the PiMF designation indicate?
A:- PiMF indicates that the pairs are individually screened, providing maximum protection against crosstalk and interference.
Q:- What is the test voltage for these cables?
A:- The test voltage is 2000 V (core/core) and 1000 V (core/screen).
Q:- What is the temperature range for these cables?
A:- The temperature range is -5°C to +50°C for flexing and -30°C to +70°C for fixed installation.
Q:- What is the difference between the RD and RE variants?
A:- RD variants typically use PVC insulation, while RE variants use PE insulation for lower capacitance and better high-frequency performance.
Q:- What is the largest configuration available in the provided tables?
A:- The largest configuration shown is 96X2X0,5 Bd in the RD-Y(St)Y series.
Q:- Are other dimensions available besides those listed?
A:- Yes, further dimensions are available upon request.