NHXMH-O & NHXMH-J 300/500 V Halogen-Free Flame Retardant Cable – DIN VDE 0250
The NHXMH-O and NHXMH-J 300/500 V cables deliver dependable power distribution for safety-critical environments like power stations, hotels, and public buildings. Constructed with copper conductors, XLPE insulation, and halogen-free flame retardant sheaths, they offer exceptional fire safety with low smoke and corrosion emissions. Because they meet DIN VDE 0250 standards and are CE/RoHS compliant, they provide a safe and reliable solution for indoor and outdoor installations.
Application
NHXMH-O and NHXMH-J cables provide reliable power distribution with low halogen fire smoke emission and corrosion at fire conditions. Because of these safety features, installers use them in electrical installations for Uo/U 300/500 V. Furthermore, they are crucial for important objects like power stations, hotels, theaters, and public buildings. Additionally, they are ideal for cinemas, public commercial centers, and places where the safety of people and material values is guaranteed. The conductors are designed for laying in, on, and under plaster in dry and wet premises, as well as outdoor use. However, installers should not lay them directly in vibro concrete, rammed concrete, or directly under ground.
Cable construction
This cable strictly adheres to DIN VDE 0250 part 214 standards. It features copper wires according to VDE 0295 (IEC 60228) class 1 or 2. The insulation uses an XLPE compound 2XI1 (DIX8) according to VDE 0276-604. Core identification follows VDE 0293. Additionally, a halogen-free compound forms the inner sheath. Finally, a halogen-free compound, flame retardant type LTS 1 outer sheath protects the entire assembly. The color is grey RAL 7035. Furthermore, this product is both RoHS and CE compliant.
Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to VDE 0295 (IEC60228) class 1 or 2. The operating temperature reaches 70 °C. During a short circuit, it can withstand 160 °C for a maximum of 5 seconds. It operates at a nominal voltage of 300/500 V and undergoes a test voltage of AC – 2 kV. Installers must respect a minimum bending radius of 4 times the cable diameter. Furthermore, it passes the flame retardancy test according to DIN VDE 0472 part 804 / IEC 332-3 Cat.C. The corrosion of combustion gases has a pH of min. 4.3, max. 100 mS/m, and the density of smoke gases is according to VDE 0472-813 (IEC 60754-2) and VDE 0472-816 (IEC 61034-1/2).
Color coding
Clear color coding ensures safe and accurate wiring. Single core cables are black or yellow/green. Double core cables feature blue and brown, or yellow-green and black. Multi-core configurations include specific color sequences for easy identification. For instance, 3-core uses brown, black, and grey, or yellow/green, blue, and brown. 4-core uses blue, brown, black, and grey, or yellow/green, brown, black, and grey. 5-core uses blue, brown, black, grey, and black, or yellow/green, blue, brown, black, and grey. Multiple core uses black with number marks on cores or black with number marks on cores and a yellow/green core in the outer cover.
Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.
Construction data NHXMH-o/j 300/500 V
| Number of conductors and nominal cross section | Thickness of insulation | Thickness of sheath | Thickness of sheath | Cable diameter approx. | Mass of Cu approx. | Mass of cable approx. |
|---|---|---|---|---|---|---|
| N x mm² | mm | mm | mm | mm | kg/km | kg/km |
| 1×1,5 | 0,5 | 1,4 | 1,4 | 5,0 | 8,8 | 48 |
| 1×2,5 | 0,5 | 1,4 | 1,4 | 5,4 | 9,4 | 61 |
| 1×4,0 | 0,6 | 1,4 | 1,4 | 6,0 | 30 | 75 |
| 1×6,0 | 0,6 | 1,4 | 1,4 | 6,4 | 37 | 112 |
| 1×10 | 0,7 | 1,4 | 1,4 | 7,4 | 61 | 160 |
| 1×16 | 0,7 | 1,4 | 1,4 | 8,6 | 13,5 | 230 |
| 2×1,5 | 0,5 | 0,4 | 1,4 | 8,0 | 9,4 | 108 |
| 2×2,5 | 0,6 | 0,4 | 1,4 | 8,8 | 16,0 | 148 |
| 2×4,0 | 0,6 | 0,4 | 1,4 | 10,0 | 29 | 205 |
| 3×1,5 | 0,5 | 0,4 | 1,4 | 8,4 | 9,8 | 131 |
| 3×2,5 | 0,6 | 0,4 | 1,4 | 9,6 | 13,8 | 179 |
| 3×4,0 | 0,6 | 0,4 | 1,4 | 10,5 | 12,5 | 239 |
| 3×6,0 | 0,6 | 0,4 | 1,6 | 11,5 | 16,8 | 369 |
| 3×10 | 0,7 | 0,6 | 1,6 | 12,0 | 16,5 | 503 |
| 3×16 | 0,7 | 0,6 | 1,6 | 17,0 | 20,0 | 725 |
| 3×25 | 0,9 | 0,8 | 1,8 | 21,0 | 25,5 | 1050 |
| 3×35 | 0,9 | 0,8 | 1,8 | 25,0 | 26,0 | 1298 |
| 4×1,5 | 0,5 | 0,4 | 1,4 | 9,0 | 10,5 | 150 |
| 4×2,5 | 0,6 | 0,4 | 1,4 | 10,0 | 11,5 | 211 |
| 4×4,0 | 0,6 | 0,4 | 1,6 | 12,0 | 14,0 | 303 |
| 4×6,0 | 0,6 | 0,6 | 1,6 | 13,0 | 16,0 | 406 |
| 4×10 | 0,7 | 0,6 | 1,6 | 15,5 | 18,0 | 630 |
| 4×16 | 0,7 | 0,6 | 1,6 | 19,0 | 22,5 | 874 |
| 4×25 | 0,9 | 0,8 | 1,8 | 22,5 | 26,0 | 1220 |
| 4×35 | 0,9 | 0,8 | 1,8 | 26,5 | 31,0 | 1735 |
| 5×1,5 | 0,5 | 0,4 | 1,4 | 9,6 | 11,5 | 178 |
| 5×2,5 | 0,6 | 0,4 | 1,6 | 10,5 | 12,5 | 240 |
| 5×4,0 | 0,6 | 0,6 | 1,6 | 13,0 | 15,5 | 380 |
| 5×6,0 | 0,6 | 0,6 | 1,6 | 14,0 | 17,0 | 500 |
| 5×10 | 0,7 | 0,6 | 1,8 | 17,0 | 19,5 | 770 |
| 5×16 | 0,7 | 0,6 | 1,8 | 21,0 | 25,0 | 1100 |
| 5×25 | 0,9 | 0,8 | 1,8 | 25,5 | 28,5 | 1740 |
| 5×35 | 0,9 | 0,8 | 2,0 | 28,5 | 34,0 | 2495 |
| 7×1,5 | 0,5 | 0,4 | 1,4 | 10,0 | 12,0 | 210 |
| 7×2,5 | 0,5 | 0,4 | 1,6 | 12,0 | 14,0 | 302 |
Factory Overview

Packaging & Shipping
Frequently asked questions and answer ( Q:- A:- )
Q:- What is the primary application of the NHXMH-O and NHXMH-J cables?
A:- They are used in electrical installations for Uo/U 300/500 V, particularly in power stations, hotels, theaters, public buildings, and places with high concentrations of people.
Q:- What are the key safety features of this cable?
A:- It is a halogen-free, flame retardant cable with low halogen fire smoke emission and corrosion at fire conditions, passing DIN VDE 0472 part 804 / IEC 332-3 Cat.C.
Q:- What standards does the cable construction follow?
A:- The construction adheres to DIN VDE 0250 part 214 standards, and the conductor complies with VDE 0295 (IEC 60228) class 1 or 2.
Q:- What type of conductor and insulation does it use?
A:- It uses copper wires with XLPE compound 2XI1 (DIX8) insulation according to VDE 0276-604.
Q:- Where can this cable be installed?
A:- The conductors are designed for laying in, on, and under plaster in dry and wet premises, as well as outdoor use, but not directly in vibro concrete, rammed concrete, or directly under ground.
Q:- What is the rated voltage and maximum conductor temperature?
A:- The rated voltage is 300/500 V, and the maximum operating temperature is 70°C.
Q:- What is the short-circuit temperature limit?
A:- It can withstand a short circuit temperature of 160°C for a maximum of 5 seconds.
Q:- What is the test voltage for this cable?
A:- The test voltage is AC – 2 kV.
Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 4 times the cable diameter (4x D cable).
Q:- What is the color coding for the 3-core variant?
A:- The 3-core variant features brown, black, grey, or yellow/green, blue, and brown colors.



Reviews
There are no reviews yet.