LSZH/OSCR/LSZH/SWA/LSZH Armoured Screened Halogen-Free Control Cable – ESI 09-6
The LSZH/OSCR/LSZH/SWA/LSZH cable delivers dependable communication and control connections for industrial and infrastructure applications. Constructed with solid tinned copper conductors, halogen-free polymer insulation, twisted pairs, an aluminum tape screen, steel wire armour, and a halogen-free outer sheath, it offers exceptional fire safety and high mechanical resistance. Because it meets ESI 09-6 standards and is RoHS compliant, it provides a safe and reliable solution for electrical instrument circuits in fire-risk environments.
Application
LSZH/OSCR/LSZH/SWA/LSZH cables provide reliable communication and control connections for industrial and infrastructure applications. Because they feature low smoke zero halogen (LSZH) materials, a robust screen, and steel wire armour, installers use them in electrical instrument circuits to provide communication services. Furthermore, they are explicitly designed for areas where a fire could create dense smoke and toxic fumes, ensuring safety for personnel and equipment.
Cable construction
This cable adheres to ESI 09-6, issue 6 standards. It features a solid tinned copper conductor with a diameter of 0.8 mm. The insulation uses a halogen-free polymer compound. Each pair is twisted, with pairs stranded into layers with a minimum of 1 layer of plastic tape. A screen of aluminum tape (one side coated with polyester and 1 solid tinned copper wire with a diameter of 0.8mm) provides overall shielding. A halogen-free polymer compound forms the inner sheath (complying to BS 7655, part 6.1). A single layer of galvanized steel wires (according to BS 1442) provides the armour. The outer sheath uses a halogen-free polymer compound (complying to BS 7655, part 6.1). Furthermore, this product is RoHS compliant.
Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C of max. 36.8 MΩ/km. The insulation resistance is min. 150 MΩ.km. The mutual capacitance at 800 Hz is max. 150 nF/km. The capacitance unbalance at 800 Hz is max. 270 pF/500m. The test voltage is 50 Hz, 1 min for 800V (wire-wire) and 1500V (wire-screen). The operating voltage is 150V. The temperature range is mobile -5 °C to +50 °C and fixed -30 °C to +70 °C. The minimum bending radius is 15 x cable diameter.
Cable core construction
The pairs are arranged in layers or units for larger counts. For instance, a 30-pair cable consists of one unit of 3×10-pair, one unit of 5×10-pair, and one unit of 2×20-pair. Units are identified by color tape: Unit 1 (Blue), Unit 2 (Orange), Unit 3 (Green), Unit 4 (Brown), and Unit 5 (Grey).
Color coding
Clear color coding ensures safe and accurate wiring. The 2-pair (quad cables) use white, red, blue, and orange. For multi-pair cables, the a-wire colors include white, black, red, etc., and the b-wire colors include blue, orange, green, etc.
Type codes
LSZH = halogen-free polymer compound, SWA = armour, OSCR = screen of aluminum tape.
Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.
Mechanical data LSZH/OSCR/LSZH/SWA/LSZH …x2x0.8
| Number of pairs | Diameter of armour wire | External diameter approx. | Copper weight | Cable weight approx. |
|---|---|---|---|---|
| mm | mm | kg/km | kg/km | |
| 1x2x0.8 | 0,90 | 8,1 | 14 | 175 |
| 2x2x0.8 | 0,90 | 10,3 | 24 | 259 |
| 5x2x0.8 | 0,90 | 13,3 | 52 | 365 |
| 10x2x0.8 | 1,25 | 17,0 | 98 | 620 |
| 15x2x0.8 | 1,25 | 18,6 | 145 | 745 |
| 20x2x0.8 | 1,25 | 20,8 | 192 | 899 |
| 30x2x0.8 | 1,25 | 24,2 | 285 | 1139 |
| 40x2x0.8 | 1,60 | 27,3 | 380 | 1559 |
| 50x2x0.8 | 1,60 | 31,6 | 475 | 1870 |
Factory Overview
Packaging & Shipping
Frequently asked questions and answer ( Q:- A:- )
Q:- What is the primary application of the LSZH/OSCR/LSZH/SWA/LSZH cable?
A:- It is used in electrical instrument circuits to provide communication services, particularly in areas where a fire could create dense smoke and toxic fumes.
Q:- What are the key safety and mechanical features of this cable?
A:- It features halogen-free polymer compounds for low smoke and zero halogen emissions, an aluminum tape screen (OSCR) for signal protection, and galvanized steel wire armour (SWA) for high mechanical resistance.
Q:- What standards does the cable construction follow?
A:- The construction adheres to ESI 09-6, issue 6 standards, and the sheath compounds comply with BS 7655, part 6.1.
Q:- What type of conductor and insulation does it use?
A:- It uses a solid tinned copper conductor with a halogen-free polymer compound insulation.
Q:- What is the temperature range for this cable?
A:- The fixed temperature range is -30°C to +70°C, and the mobile temperature range is -5°C to +50°C.
Q:- What is the mutual capacitance of this cable?
A:- The mutual capacitance at 800 Hz is max. 150 nF/km.
Q:- What is the test voltage for this cable?
A:- The test voltage is 50 Hz, 1 min for 800V (wire-wire) and 1500V (wire-screen).
Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 15 times the cable diameter.
Q:- What is the conductor resistance at 20°C?
A:- The conductor resistance at 20°C is max. 36.8 MΩ/km.
Q:- What do the type codes LSZH, SWA, and OSCR stand for?
A:- LSZH indicates a halogen-free polymer compound, SWA indicates armour, and OSCR indicates a screen of aluminum tape.