AGKABEL Halogen-Free Safety Cables NHXCH – FE 180, E30 / E90

High-performance circuit integrity cables designed for safety-critical systems. They are halogen-free, flame-retardant, and maintain circuit integrity for 180 minutes (FE 180), meeting E30 or E90 classification. Suitable for indoor installation in dry and wet zones, in/on/under plaster, and for outdoor installation (not for direct burial). Compliant with DIN VDE 0266 and IEC 332-3. Nominal voltage: 0.6/1 kV. Available from 1 to 2 cores, 1.5mm² to 300mm².

AGKABEL GRUPPE LIMITED presents the Halogen-Free Safety Cables NHXCH FE 180 E30 or E90, engineered for maximum safety and reliability in emergency situations. These cables are designed to maintain circuit integrity during a fire (FE 180 for 180 minutes), ensuring that critical systems such as fire alarms, emergency lighting, and smoke extraction fans continue to operate. The halogen-free construction prevents the emission of toxic and corrosive gases, and the flame-retardant properties limit fire spread. They are suitable for indoor installation in dry and wet zones, in, on, and under plaster, as well as for outdoor installation (but not for direct laying below ground).

Technical Data

  • Standard: DIN VDE 0266

  • Nominal voltage: 0.6/1 kV

  • Flame-retardant: IEC 332-3

  • Application: For indoor installation in dry and wet zones, in, on and under plaster. Further use for outdoor installation. But not suitable for direct laying below ground.

  • Classification: E30 (maintains circuit integrity for 30 minutes) or E90 (maintains circuit integrity for 90 minutes).

Technical Specifications Table

E30 Series

Part N° N° of cores x cross-sec mm² Outer diameter ca. mm Copper weight kg/km Weight ca. kg/km
11636001 1X4 RE 8,0 38,00 90,00
11636002 1X6 RE 9,0 58,00 100,00
11636003 1X10 RE 10,0 96,00 135,00
11636004 1X16 RE 11,0 154,00 190,00
11636005 1X25 RM 12,0 240,00 290,00
11636006 1X35 RM 13,0 336,00 380,00
11636007 1X50 RM 15,0 480,00 510,00
11636008 1X70 RM 17,0 672,00 695,00
11636009 1X95 RM 19,0 912,00 970,00
11636010 1X120 RM 21,0 1.152,00 1.230,00
11636011 1X150 RM 23,0 1.440,00 1.520,00
11636012 1X185 RM 26,0 1.776,00 1.840,00
11636013 1X240 RM 28,0 2.304,00 2.470,00
11636014 1X300 RM 31,0 2.880,00 o. r.
11636015 2X1,5 RE 12,0 29,00 180,00
11636016 2X2,5 RE 13,0 48,00 210,00
11636017 2X4 RE 14,0 77,00 260,00
11636018 2X6 RE 15,0 115,00 320,00
11636019 2X10 RE 16,0 192,00 440,00
11636020 2X16 RM 19,0 307,00 620,00
11636021 2X25 RM 22,0 480,00 920,00

E90 Series

Part N° N° of cores x cross-sec mm² Outer diameter ca. mm Copper weight kg/km Weight ca. kg/km
11605023 1X4 RE o. r. 38,00 98,00
11605028 1X6 RE 10,0 58,00 120,00
11605033 1X10 RE 10,0 96,00 165,00
11605038 1X16 RE 11,0 154,00 230,00
11605043 1X25 RM 13,0 240,00 340,00
11605048 1X35 RM 14,0 336,00 440,00
11605053 1X50 RM 16,0 480,00 590,00
11605058 1X70 RM 18,0 672,00 800,00
11605062 1X95 RM 20,0 912,00 1.100,00
11605066 1X120 RM 21,0 1.152,00 1.350,00
11605069 1X150 RM 24,0 1.440,00 1.650,00
11605072 1X185 RM 26,0 1.776,00 2.000,00
11605074 1X240 RM 29,0 2.304,00 2.600,00
11605076 1X300 RM 32,0 2.880,00 3.300,00
11605001 2X1,5 RE 14,0 29,00 210,00
11605012 2X2,5 RE 15,0 48,00 250,00
11605024 2X4 RE 16,0 77,00 310,00
11605029 2X6 RE 17,0 115,00 380,00
11605034 2X10 RE 19,0 192,00 510,00
11605039 2X16 RE 21,0 307,00 680,00
11605044 2X25 RM 25,0 480,00 1.050,00

(Further dimensions available on request. Note: o. r. = on request/variable.)

 

Factory Overview


Packaging & Shipping


Fly

❓ Frequently Asked Questions (FAQ)

1. What are the primary applications for these cables?
They are designed for safety-critical systems such as fire alarms, emergency lighting, and smoke extraction fans. They are suitable for indoor installation in dry and wet zones, in, on, and under plaster, and for outdoor installation (not for direct laying below ground).

2. What is the difference between E30 and E90?

  • E30: The cable maintains circuit integrity for at least 30 minutes in the event of a fire.

  • E90: The cable maintains circuit integrity for at least 90 minutes in the event of a fire.

3. What does “FE 180” mean?
FE 180 indicates that the cable can maintain insulation integrity for 180 minutes under direct flame exposure, which is a key requirement for critical safety circuits.

4. What are the benefits of halogen-free construction?
Halogen-free cables are safer in fire situations as they do not emit toxic or corrosive halogen gases, and they produce minimal smoke, allowing for clearer evacuation routes.

5. What is the voltage rating of these cables?
The nominal voltage is 0.6/1 kV.

6. What standard do these cables comply with?
They comply with DIN VDE 0266 and are flame-retardant according to IEC 332-3.

7. What sizes and core configurations are available?
Available from 1 to 2 cores, with conductor sizes ranging from 1.5mm² to 300mm².

Reviews

There are no reviews yet.

Be the first to review “AGKABEL Halogen-Free Safety Cables NHXCH – FE 180, E30 / E90”

Your email address will not be published. Required fields are marked *