Cu/XLPE/PVC/AWA/PVC 0.6/1 kV Armoured Power Cable – BS 5467-1997

The Cu/XLPE/PVC/AWA/PVC 0.6/1 kV single-core cable delivers dependable power distribution for industrial installations and power stations. Constructed with copper conductors, XLPE insulation, non-magnetic aluminum wire armour, and a black PVC outer sheath, it offers excellent mechanical protection and LSOH safety features. Because it meets BS 5467 standards and is RoHS compliant, it provides a safe and reliable solution for cable ducts, tunnels, and underground installations.

Application
Cu/XLPE/PVC/AWA/PVC single-core power cables provide reliable power distribution for industrial installations and electrical power stations. They operate efficiently with a nominal voltage of 0.6/1 kV and a frequency of 50 Hz. Because the LSOH cables are flame retardant with low halogen smoke emission and corrosion at fire conditions, they are highly suitable for safe use in distribution networks, electrical substations, and other installations. Furthermore, installers use them for fixed assembly in lines with unlimited differences levels, in industrial sites, indoor installations, cable ducts, and conduits. Additionally, they perform reliably on shelves, grilles, directly underground in ditch, and outdoor under shelters.

Cable construction
This cable strictly adheres to BS 5467-97 standards. It features copper wires stranded according to BS 6360 (IEC 60228) class 2. The insulation uses XLPE compound with black and red colors. Additionally, a PVC compound forms the inner sheath. The armour consists of non-magnetic aluminum wires laid concentrically. Finally, a black PVC compound type 9 sheath protects the entire assembly. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to BS 6360 (IEC 60228) class 2. The operating temperature reaches a maximum of 90 °C continuous. During an overload, it can withstand 130 °C for 100% per year max. In a short circuit, it withstands 250 °C for a maximum of 5 seconds. It operates at a nominal voltage of 0.6/1 kV, while the highest system voltage is 1.2 kV. Test voltage AC is applied for 5 minutes at 3.5 kV between core and screen. Installers must respect a minimum bending radius of 6 times the cable diameter. The laying temperature should not fall below 0 °C, and the explosion temperature ranges from -30 to 50 °C. The force of strain in laying max is Cu cores – 50NS (N=number of cores, S=nominal cross section of cores in mm).

Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data Cu/XLPE/PVC/AWA/PVC

Number of conductors and nominal cross section Thickness of insulation Diameter of Al wires in armour Thickness of sheath Cable diameter approx. Mass of Cu approx. Cable weight approx.
N x mm² mm mm mm mm kg/km kg/km
1×150 mm 1,4 1,6 1,7 26,2 1378 1722
1×185 mm 1,6 1,6 1,8 28,2 1703 2113
1×240 mm 1,7 1,6 1,8 31,4 2208 2696
1×300 mm 1,8 1,6 2,0 33,9 2760 3230
1×400 mm 2,0 1,6 2,0 35,9 3680 4026
1×500 mm 2,2 2,0 2,1 42,8 4600 5381

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the Cu/XLPE/PVC/AWA/PVC cable?
A:- It is used for the distribution networks, electrical power stations, and substations for fixed assembly in lines with unlimited differences levels.

Q:- Where can this single-core cable be installed?
A:- It is suitable for industrial sites, indoor installations, cable ducts and conduits, on shelves, grilles, directly underground in ditch and outdoor under shelters.

Q:- What standards does the cable construction follow?
A:- The construction adheres to BS 5467-97 standards, and the conductor complies with BS 6360 (IEC 60228) class 2.

Q:- What are the key fire safety features of this cable?
A:- It features LSOH (Low Smoke Zero Halogen) characteristics with low halogen smoke emission, flame retardant properties, and corrosion resistance at fire conditions.

Q:- What type of armour protects this cable?
A:- The cable features an armour made of non-magnetic aluminum wires laid concentrically.

Q:- What is the nominal voltage and highest system voltage?
A:- The nominal voltage Uo/U is 0.6/1 kV, and the highest system voltage is 1.2 kV.

Q:- What are the maximum continuous and short circuit temperatures?
A:- The maximum operating temperature is 90°C continuous, and it can withstand a short circuit temperature of 250°C for a maximum of 5 seconds.

Q:- What is the overload temperature capacity?
A:- It can withstand an overload temperature of 130°C for 100% per year maximum.

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 6 times the cable diameter (6x D cable).

Q:- What are the temperature limits for laying and explosion?
A:- The laying temperature should be no less than 0°C, and the explosion temperature range is -30 to 50°C.

Reviews

There are no reviews yet.

Be the first to review “Cu/XLPE/PVC/AWA/PVC 0.6/1 kV Armoured Power Cable – BS 5467-1997”

Your email address will not be published. Required fields are marked *