Cu/XLPE/CTS/LSF/SWA/LSF 6.35/11 kV Halogen-Free Armoured Cable – BS 7835

The Cu/XLPE/CTS/LSF/SWA/LSF 6.35/11 kV cable delivers dependable power transfer and distribution for medium voltage networks. Constructed with copper or aluminum conductors, XLPE insulation, steel galvanized wire armour, and a halogen-free flame retardant outer sheath, it offers exceptional fire safety and mechanical protection. Because it meets BS 7835 standards and is RoHS compliant, it provides a safe and reliable solution for power stations, substations, and indoor installations.

Application
Cu/XLPE/CTS/LSF/SWA/LSF cables provide reliable transfer and distribution of electrical power in power supply networks. They operate efficiently with a nominal voltage of Uo/U 6.35/11 kV and a frequency of 49 to 61 Hz, in urban and district electrical networks. Because they feature halogen-free materials with flame retardant and low smoke properties, installers use them for electrical power stations and substations. Furthermore, these cables are suitable for fixed assembly in lines with unlimited difference levels. Additionally, they perform reliably for interior installation in cable ducts, conduits, and shafts, as well as on shelves, grilles, and outdoor under shelters.

Cable construction
This cable strictly adheres to BS 7835:2000 standards. It features copper or aluminum stranded compacted conductors according to BS 6362-1999, IEC 228, class 2. The inner semi-conductive layer, insulation, and outer semi-conductive layer all use XLPE or semi-conductive XLPE compounds. The metal screen can be either -i-option (Cu tapes over each phase laid with overlap) or -ii-option (Cu wires laid concentrically). The cable assembly features three insulated and screened phases twisted with fillings and a tape support. A halogen-free compound forms the separating layer. The armour consists of steel galvanized wires laid concentrically. Finally, a halogen-free flame retardant compound type LTS 1 outer sheath protects the entire assembly. The color is red or black. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to BS 6362-1999 class 2. The operating temperature reaches 90 °C continuous. During an overload, it can withstand 130 °C for 100% per year max. In a short circuit, it withstands 250 °C for a maximum of 5 seconds. It operates at a nominal voltage of Uo/U 6.35/11 kV, while the highest system voltage is 12 kV. Test voltage is AC (+) – 15 min for 25.5 kV. The level of partial discharge at 12.5 kV is max. 10 pC. The minimum bending radius is 15 times the cable diameter. The temperature of laying is no less than 0 °C. The temperature of explosion is -30 to 50 °C. Testing follows BS 4066-3 (IEC 332-3 category C). The force of strain in laying max is Al cores: 30NS core, Cu cores: 50NS core, where N is the number of cores and S is the cross-section of cores in mm.

Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data Cu/XLPE/CTS/LSF/SWA/LSF 6.35/11 kV

Number of conductors and nominal cross section Thickness of insulation Diameter of St wires for armour Thickness of sheath Cable diameter approx. Mass of Cu approx. Mass of cable approx.
N x mm² mm mm mm mm kg/km kg/km
Uo/U 6.35/11 kV
3x35m/16 3,4 2,5 2,4 48,8 850 4200
3x50m/25 3,4 2,5 2,5 51,6 1385 5100
3x70m/35 3,4 2,5 2,6 56,0 1560 5650
3x95m/50 3,4 2,5 2,7 58,5 2855 7600
3x120m/70 3,4 2,5 2,8 62,6 3670 8300

Note: Other core configuration and special constructions manufactured upon request.

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the Cu/XLPE/CTS/LSF/SWA/LSF cable?
A:- It is designed for the transfer and distribution of electrical power in urban and district networks, specifically for electrical power stations and substations.

Q:- What are the key fire safety features of this cable?
A:- It features halogen-free materials with flame retardant and low smoke properties, passing the BS 4066-3 (IEC 332-3 category C) flame test.

Q:- What standards does the cable construction follow?
A:- The construction adheres to BS 7835:2000 standards, and the conductor complies with BS 6362-1999, IEC 228, class 2.

Q:- What type of conductor and insulation does it use?
A:- It uses Cu or Al stranded compacted conductors with XLPE insulation.

Q:- What kind of armour protects this cable?
A:- The cable features an armour made of steel galvanized wires laid concentrically.

Q:- What is the rated voltage and maximum conductor temperature?
A:- The rated voltage is Uo/U 6.35/11 kV, and the continuous operating temperature is 90°C.

Q:- What are the short-circuit and overload temperature limits?
A:- It can withstand a short circuit temperature of 250°C for a maximum of 5 seconds and an overload temperature of 130°C for 100% per year max.

Q:- What is the test voltage for this cable?
A:- The test voltage is AC (+) – 15 min for 25.5 kV.

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 15 times the cable diameter (15x D cable).

Q:- What are the temperature limits for laying and explosion?
A:- The temperature of laying is no less than 0°C, and the temperature of explosion is -30 to 50°C.

Reviews

There are no reviews yet.

Be the first to review “Cu/XLPE/CTS/LSF/SWA/LSF 6.35/11 kV Halogen-Free Armoured Cable – BS 7835”

Your email address will not be published. Required fields are marked *

RELATED PRODUCTS