AGKABEL Bare Stranded Conductor AAC – ASTM & BS Standards

All Aluminium Conductors (AAC) designed for aerial power transmission lines. Manufactured to meet ASTM and BS standards, these conductors feature high conductivity, lightweight construction, and excellent corrosion resistance. Available in a wide range of industry-standard code names (e.g., Peachbell, Midge) and sizes ranging from AWG/MCM to mm².

AGKABEL GRUPPE LIMITED presents our premium line of Bare Stranded Conductors (AAC), engineered specifically for aerial power transmission lines. All Aluminium Conductors (AAC) are widely used in urban and rural overhead distribution networks due to their excellent electrical conductivity, low weight, and superior resistance to atmospheric corrosion. This makes them an ideal, cost-effective solution for short to medium-span transmission lines where high tensile strength is not the primary requirement.

Technical Data

  • Conductor Type: All Aluminium Conductor (AAC)

  • Application: Aerial power transmission lines

  • Standards: ASTM and BS

  • Features: High conductivity, lightweight, excellent corrosion resistance.

Technical Specifications Table – AAC (ASTM Standard)

Code Name AWG or MCM mm² No./mm OD./mm Approx. weight (Kg/km) Breaking load (kN) DC resistance (20°C) (Ω/km)
Peachbell 6 13.29 7/1.554 4.67 37 249 2.1692
Pose 4 21.16 7/1.961 5.89 58 396 1.3624
Iris 2 33.61 7/2.474 7.42 93 597 0.8577
Pansy 1 42.39 7/2.776 8.33 117 732 0.6801
Poppy 1/0 53.48 7/3.119 9.36 147 873 0.539
Aster 2/0 67.42 7/3.503 10.51 186 1100 0.4276
Phlox 3/0 85.03 7/3.932 11.8 234 1347 0.339
Oxlip 4/0 107.23 7/4.417 13.26 296 1698 0.2688
Valerian 250 126.71 19/2.913 14.57 349 2062 0.2275
Sneezewort 250 126.71 7/4.80 14.4 349 2007 0.2275
Laurel 266.8 135.16 19/3.01 15.05 373 2200 0.2133
Daisy 266.8 135.16 7/4.96 14.9 373 2141 0.2133
Peony 300 152 19/3.193 15.97 419 2403 0.1896
Tulip 336.4 170.45 19/3.381 16.91 470 2695 0.1691
Daffodil 350 177.35 19/3.447 17.24 489 2804 0.1625
Canna 397.5 201.42 19/3.673 18.36 555 3184 0.1431
Goldentuff 450 228 19/3.909 19.55 629 3499 0.1264
Syringa 477 241.68 37/2.882 20.19 666 3849 0.1193
Cosmos 477 241.68 19/4.023 20.12 666 3708 0.1193
Hyacinth 500 253.35 37/2.951 20.65 698 4035 0.1138
Zinnia 500 253.35 19/4.12 20.6 698 3888 0.1138
Dahlia 556.5 282 19/4.346 21.73 777 4327 0.1022
Mistletoe 556.5 282 37/3.114 21.79 777 4362 0.1022
Meadowsweet 600 304 37/3.233 22.63 838 4703 0.0948
Orchid 636 322.25 37/3.33 23.31 838 4985 0.0894
Flag 700 354.71 61/2.72 24.48 978 5146 0.0813
Verbena 700 354.71 37/3.493 24.45 978 5487 0.0813
Nasturtium 715.5 362.58 61/2.75 24.76 1000 5874 0.0795
Violet 715.5 362.58 37/3.533 24.74 1000 5609 0.0795
Cattail 750 380 61/2.817 25.35 1048 5985 0.0759
Petunia 750 380 37/3.617 25.32 1048 5875 0.0759
Lilac 795 402.84 61/2.90 26.06 1111 6345 0.0715
Artubus 795 402.84 37/3.724 26.05 1111 6232 0.0715
Snapdragon 900 456.06 61/3.086 27.78 1257 6978 0.0632
Cockscomb 900 456.06 37/3.962 27.73 1257 6848 0.0632
Goldenrod 954 483.42 61/3.177 28.6 1333 7896 0.0596
Magnolia 954 483.42 37/4.079 28.55 1333 7258 0.0596
Camelia 1000 506.71 61/3.251 29.36 1397 7753 0.0569
Hawkweed 1000 506.71 37/4.176 29.23 1397 7608 0.0569
Larkspur 1033.5 523.68 61/3.307 29.76 1444 8012 0.055
Bluebell 1033.5 523.68 37/4.244 29.72 1444 7863 0.055
Marigold 1113 563.93 61/3.432 30.89 1555 8628 0.0511
Hawthorn 1192.5 604.26 61/3.551 31.05 1666 9245 0.0477

 

Technical Specifications Table – AAC (BS Standard)

Code Name Nominal Area (mm²) Sectional Area (mm²) No./mm OD./mm Approx. weight (Kg/km) Breaking load (kN) DC resistance (20°C) (Ω/km)
Midge 22 23.33 7/2.06 6.18 64 399 1.227
Aphis 25 26.4 7/3.35 7.2 73 411 1.081
Ghat 25 26.8 7/2.21 6.6 73 459 1.066
Weevil 30 31.6 3/3.33 7.9 86 486 0.9082
Mosquito 35 370 7/2.59 7.9 101 603 0.7762
Ladybind 40 42.8 7/2.79 8.4 117 687 0.6689
Ant 50 52.83 7/3.10 9.3 145 828 0.5419
Fly 60 63.55 7/3.40 10.2 174 990 0.4505
Bluebottle 70 73.7 7/3.66 11 202 1134 0.3881
Earwing 75 78.5 7/3.78 11.4 215 1194 0.3644
Grasshopper 80 84.1 7/3.91 11.7 230 1278 0.3406
Clegg 90 95.6 7/4.17 12.5 262 1453 0.2994
Wasp 100 106 7/4.39 13.17 290 1600 0.2702
Beetle 100 106 19/2.67 13.4 293 1742 0.2704
Bee 125 132 7/4.90 14.7 361 1994 0.2169
Cricket 150 157.9 7/5.36 16.1 432 2385 0.1818
Hornet 150 157.6 19/3.25 16.25 434 2570 0.1825
Caterpillar 175 186 19/3.53 17.7 512 2863 0.1547
Chafer 200 213.2 19/3.78 18.9 587 3240 0.1349
Spider 225 236.9 19/3.99 20 652 3601 0.1211
Cockroach 250 265.7 19/4.22 21.1 731 4040 0.1083
Butterfly 300 322.7 19/4.65 23.25 888 4875 0.08916
Moth 350 373.2 19/5.00 25 1027 5637 0.07711
Drone 350 373.3 37/3.58 25.1 1029 5745 0.07741
Locust 400 428.5 19/5.36 26.8 1179 6473 0.0671
Centipede 400 415.5 37/3.78 26.46 1145 6310 0.06944
Maybug 450 486.9 37/4.09 28.6 1342 7401 0.05931
Scordion 500 529.5 37/4.27 29.9 1460 7998 0.5441
Cicada 600 628.6 37/4.65 32.6 1733 9495 0.04588
Tarantula 750 794.6 37/5.23 36.6 2191 12010 0.03627

 

Factory Overview


Packaging & Shipping


Fly

❓ Frequently Asked Questions (FAQ)

1. What is an AAC conductor?
AAC stands for All Aluminium Conductor. It is a type of bare stranded conductor made entirely of aluminium strands.

2. What are the primary applications for AAC?
It is designed for aerial power transmission and distribution lines, particularly in urban areas and short to medium spans where high tensile strength is not a primary requirement.

3. What are the benefits of using AAC?

  • Lightweight: Easier to handle and install.

  • High Conductivity: Excellent electrical performance.

  • Corrosion Resistance: Highly resistant to atmospheric corrosion, making it suitable for coastal and industrial areas.

  • Cost-Effective: Generally more economical than copper or steel-reinforced conductors.

4. What standards are these conductors manufactured to?
Our AAC conductors are manufactured to meet the rigorous requirements of ASTM (American Society for Testing and Materials) and BS (British Standards) specifications.