Heavy-duty energy distribution cables featuring a corrugated copper concentric conductor for enhanced safety, mechanical protection, and EMC performance. Designed for fixed installation in buildings and direct laying in concrete, water, and underground. Compliant with DIN VDE 0276 part 603. Temperature range: -5°C to +50°C (Flexing) | -30°C to +70°C (Fixed). Nominal voltage: 0.6/1 kV. Test voltage: 4 kV. Available from 2 to 4 cores, 6mm² to 240mm².

AGKABEL GRUPPE LIMITED presents the Power Cables NYCWY, engineered for robust energy distribution with superior safety features. The key feature of this cable is the corrugated concentric copper conductor (a wave-shaped copper layer surrounding the insulated cores). This design serves as a combined neutral and earth (PE/PEN) conductor, provides excellent electromagnetic screening (EMC), and offers high mechanical protection against external damage. Designed for fixed installation in buildings, these cables are also suitable for direct laying in concrete, water, and below ground.

Technical Data

  • Standard: DIN VDE 0276 part 603

  • Temperature range:

    • Flexing: -5°C to +50°C

    • Fixed installation: -30°C to +70°C

  • Nominal voltage: 0.6/1 kV

  • Test voltage: 4 kV

  • Application: Energy distribution cable for fixed installation in buildings, for direct laying in concrete, water and below ground.

Technical Specifications Table

Part N° N° of cores x cross-sec mm² Outer diameter ca. mm Copper weight kg/km Weight ca. kg/km
Small to Medium Sizes (6mm² to 35mm²)
12004032 3X6 RE/6 18,0 245,00 570,00
12004001 2X10 RE/10 19,0 312,00 644,00
12004002 3X10 RE/10 20,0 408,00 728,00
12004030 3X10 RE/10 bl 20,0 408,00 728,00
12004003 4X10 RE/10 21,0 504,00 864,00
12004031 2X16 RE/16 21,0 489,00 884,00
12004004 3X16 RE/16 22,0 643,00 1.006,00
12004005 4X16 RE/16 23,0 796,00 1.220,00
12004006 3X25 RM/16 26,0 902,00 1.443,00
12004007 3X25 RM/25 26,0 1.003,00 1.516,00
12004008 4X25 RM/16 28,0 1.142,00 1.730,00
12004009 4X25 RM/25 29,0 1.243,00 1.900,00
12004010 3X35 SM/16 27,0 1.190,00 1.737,00
12004011 3X35 SM/35 27,0 1.402,00 1.850,00
Larger Sizes (35mm² to 120mm²)
12004012 4X35 SM/16 28,0 1.526,00 2.100,00
12004013 3X50 SM/25 30,0 1.723,00 2.200,00
12004016 3X50 SM/50 30,0 2.000,00 2.400,00
12004017 4X50 SM/25 32,0 2.203,00 2.750,00
12004014 3X70 SM/35 33,0 2.410,00 3.000,00
12004019 3X70 SM/70 33,0 2.796,00 3.300,00
12004018 4X70 SM/35 36,0 3.082,00 3.750,00
12004015 3X95 SM/50 38,0 3.296,00 4.000,00
12004021 3X95 SM/95 38,0 3.791,00 4.500,00
12004020 4X95 SM/50 42,0 4.208,00 5.100,00
12004022 3X120 SM/70 41,0 4.236,00 5.000,00
12004033 3X120 SM/120 43,0 4.786,00 5.700,00
12004023 4X120 SM/70 46,0 5.388,00 6.400,00
Extra Large Sizes (150mm² to 240mm²)
12004024 3X150 SM/70 46,0 5.100,00 6.000,00
12004034 3X150 SM/150 47,0 5.970,00 7.000,00
12004025 4X150 SM/70 50,0 6.540,00 7.700,00
12004026 3X185 SM/95 51,0 6.383,00 7.500,00
12004028 3X240 SM/120 56,0 8.242,00 9.828,00
12004029 4X240 SM/120 62,0 10.546,00 11.000,00

(Further dimensions available on request.)

 

Factory Overview


Packaging & Shipping


Fly

 

❓ Frequently Asked Questions (FAQ)

1. What are the primary applications for these cables?
They are designed for energy distribution and fixed installation in buildings, and are suitable for direct laying in concrete, water, and below ground.

2. What is the difference between NYCY and NYCWY?
The main difference is the concentric conductor design:

  • NYCY uses a standard layer of round copper wires.

  • NYCWY uses a corrugated (wave-shaped) copper conductor, which offers better flexibility, higher mechanical protection, and improved EMC performance.

3. What is the temperature range of these cables?

  • Flexing: -5°C to +50°C

  • Fixed installation: -30°C to +70°C

4. What is the voltage rating of these cables?
The nominal voltage is 0.6/1 kV and the test voltage is 4 kV.

5. What standard do these cables comply with?
They comply with DIN VDE 0276 part 603.

6. Can these cables be laid directly in water?
Yes, they are specifically designed for direct laying in water, as well as in concrete and underground.

7. What sizes and core configurations are available?
Available from 2 to 4 cores, with conductor sizes ranging from 6mm² to 240mm².

 