AGKABEL Photovoltaic Cable – 62930 IEC 131 / H1Z2Z2-K (DC1500V)

High-performance, halogen-free solar cable designed for line-line photovoltaic equipment systems up to 1.8 kV DC (Safety Class II). Features Tinned Copper Class 5 conductors, irradiation cross-linked polyolefin insulation and sheath. Engineered for extreme environments with excellent resistance to UV, ozone, weather, acids, alkalis, and abrasion. Operating temperature: -40°C to +125°C. Expected lifetime >25 years. Compliant with IEC 62930:2017. Available from 1.5mm² to 35mm².

AGKABEL GRUPPE LIMITED presents the Photovoltaic Cable (62930 IEC 131 / H1Z2Z2-K), engineered for the strict requirements of solar farms and harsh outdoor environments. Solar photovoltaic power generation is a completely zero-emission clean energy source, and these cables are designed to ensure safety, reliability, and maintenance-free operation. The cables must work under extreme conditions such as severe hot and cold temperatures, high UV radiation, and dry/wet conditions.

Technical Data

  • Standard: IEC 62930:2017

  • Voltage: DC 1500V

  • Conductor: Tinned copper stranded to IEC 60228 Class 5

  • Insulation: Halogen-free irradiation cross-linked polyolefin

  • Sheath: Halogen-free irradiation cross-linked polyolefin

  • Temperature Range: -40°C to +125°C

  • Sheath Marking: Manufacture name (trademark) and type, Production year/week or batch number, Metre-marked

  • Application: Mainly used in line-line photovoltaics equipment systems under maximum 1.8 kV DC voltage with Safety Class II. It features ozone/weather resistance, UV resistance, acid/alkali resistance, cold resistance, high wear/abrasion resistance, halogen-free, and flame retardant properties. Compatible with standard joint and connection systems.

Cable Properties

  • a) Temperature: Allowed working temperature of cable conductor for a long time is 120°C, and the short circuit temperature is 200°C for no more than 5 seconds.

  • b) Bending Radius: 4 x D (the overall diameter of the cable).

  • c) Expected Lifetime: >25 years.

  • d) Thermal Stability: Maintains insulation performance under rapid temperature changes, high ambient temperatures, and its own heat.

  • e) Moisture Resistance: Works in higher relative humidity environments (frequent rain and snow).

  • f) Radiation & Ozone Resistance: Prevents breakdown of sheath/insulation under environmental stress.

  • g) Chemical Stability: Maintains safety and stability in environments with oil, ozone, and acid-base.

  • h) Anti-Termite & Anti-Rodent: The cable jacket is resistant to termites and rodents (can also be customized with a waterproof jacket).

 

Technical Specifications Table

No. of Cores (mm²) No. of strands Insulation thick. (mm) Min. Sheath thick. (mm) Min. Mean overall diameter Upper value (mm) Min. insulation resistance at 20°C (MΩ·km) Min. insulation resistance at 90°C (MΩ·km) Max. Current Carrying Capacity (A)
1*1.5 30/0.25 0.7 0.8 5.4 1050 1,05 31
1*2.5 50/0.25 0.7 0.8 5.9 862 0,862 42
1*4.0 56/0.30 0.7 0.8 6.6 709 0,709 57
1*6.0 84/0.30 0.7 0.8 7.2 610 0,610 72
1*10.0 80/0.40 0.7 0.8 8.3 489 0,489 98
1*16.0 128/0.40 0.7 0.9 9.8 393 0,393 132
1*25.0 196/0.40 0.9 1.0 12.2 395 0,395 183
1*35.0 280/0.40 0.9 1.1 14.0 335 0,335 227

 

Factory Overview


Packaging & Shipping


Fly

❓ Frequently Asked Questions (FAQ)

1. What are the primary applications for this cable?
It is mainly used in line-line photovoltaics equipment systems under maximum 1.8 kV DC voltage with Safety Class II. It is designed for solar farms and outdoor installations requiring extreme environmental resistance.

2. What are the key environmental resistances of this cable?
It features ozone and weather resistance, UV resistance, acid and alkali resistance, cold resistance, high wear and abrasion resistance, and is halogen-free and flame retardant. It is also available with anti-termite/anti-rodent properties.

3. What is the temperature range and expected lifetime?
The operating temperature range is -40°C to +125°C. The conductor can withstand 120°C long-term and 200°C short-circuit (max 5s). The expected lifetime is >25 years.

4. What is the voltage rating of this cable?
The cable is rated for DC 1500V (suitable for systems up to 1.8 kV DC).

5. What is the bending radius?
The minimum bending radius is 4 x D (4 times the overall cable diameter).

6. What materials are used for the conductor and insulation?
The conductor is Tinned Copper stranded to IEC 60228 Class 5. Both the insulation and sheath are made of Halogen-free irradiation cross-linked polyolefin.

7. What sizes are available?
Available in single-core configurations ranging from 1.5mm² to 35mm².

Reviews

There are no reviews yet.

Be the first to review “AGKABEL Photovoltaic Cable – 62930 IEC 131 / H1Z2Z2-K (DC1500V)”