AGKABEL Low Voltage Power Cable – A2XY-O; A2XY-J (Al / XLPE / PVC)

Reliable power cables designed for the distribution and supply of consumers in industrial installations and urban networks. Features Aluminium conductors (solid or stranded), XLPE insulation, and a PVC ST2 sheath. Compliant with IEC 60502-1 and RoHS. Nominal voltage: 0.6/1 kV, 50 Hz. Operating temperature: 90°C (130°C overload, 250°C short circuit). Suitable for fixed indoor assembly in cable ducts, conduits, over shelves/grilles, directly underground, and outdoor under shelters. Available from 1x50mm² to 1x500mm² and 4x16mm² to 4x240mm².

Technical Specifications Table (Sample Sizes)

Number of conductors and nominal cross section N x mm² Thickness of insulation mm Thickness of sheath mm Outer diameter approx. min/max mm Al weight approx. kg/km Cable weight approx. kg/km
Single Core (1x)
1x50rm 1,0 1,8 14,6 – 17 135 245
1x70rm 1,1 1,8 16,5 – 19 195 318
1x95rm 1,1 1,8 18,5 – 20 270 391
1x120rm 1,2 1,8 20,0 – 22 341 469
1x150rm 1,4 1,8 21,9 – 24 419 565
1x185rm 1,6 1,8 24,1 – 27 526 681
1x240rm 1,7 1,8 26,6 – 30 690 846
1x300rm 1,8 1,8 29,4 – 32 863 1034
1x400rm 2,0 1,9 32,9 – 37 1109 1304
1x500rm 2,2 2,0 36,7 – 40 1461 1673
Multicore (4x)
4x16re 0,7 1,8 20,5 – 24 176 546
4x25re 0,9 1,8 24,3 – 31 288 792
4x35re 0,9 1,8 25,3 – 32 398 977
4x50sm 1,0 1,9 28,2 – 35 539 1259
4x70sm 1,1 2,1 32,8 – 40 779 1445
4x95sm 1,1 2,1 36,6 – 44 1079 1811
4x120sm 1,2 2,3 39,8 – 48 1364 2233
4x150sm 1,4 2,4 44,0 – 53 1676 2696
4x185sm 1,6 2,6 48,4 – 58 2105 3454
4x240sm 1,7 2,7 62,8 – 64 2762 4129

 

 

Factory Overview


Packaging & Shipping


Fly

 

❓ Frequently Asked Questions (FAQ)

1. What are the primary applications for these cables?
They are designed for the distribution and supply of consumers in industrial installations and urban networks. They are suitable for fixed indoor assembly in cable ducts and conduits, over shelves and grilles, directly underground in ditches, and outdoor under shelters.

2. What materials are used in the construction?
The cables feature Aluminium conductors (solid or stranded), XLPE (cross-linked polyethylene) insulation, and a PVC type ST2 sheath.

3. What are the temperature ratings for these cables?

  • Operating temperature: 90°C

  • Overload temperature: 130°C (for 100 hours per year)

  • Short circuit temperature: 250°C (for 5 seconds)

4. What is the voltage rating of these cables?
The nominal voltage is 0.6/1 kV (with a highest system voltage of 1.2 kV) and the AC test voltage is 4.0 kV.

5. What standards do these cables comply with?
They comply with IEC 60502-1 and are RoHS compliant. Conductor resistance is according to IEC 60228.

6. What sizes and core configurations are available?
Available in single-core (1x50mm² to 1x500mm²) and multicore (4x16mm² to 4x240mm²) configurations.

7. How are the cores identified?
Core identification follows the color code according to VDE 0276-603.

Reviews

There are no reviews yet.

Be the first to review “AGKABEL Low Voltage Power Cable – A2XY-O; A2XY-J (Al / XLPE / PVC)”

Your email address will not be published. Required fields are marked *