Flexible, copper-screened data cables designed specifically for hazardous areas, featuring a special blue outer sheath for intrinsic safety marking. Ideal as control and measuring cables for electrical apparatus installations (not earthed, requiring a separate power circuit). Extensively oil-resistant and not suitable for laying below ground. Compliant with DIN VDE 0165 part 1, EN 60079-14, and IEC 60079-14. Temperature range: -5°C to +80°C (Flexing) | -30°C to +80°C (Fixed). Nominal voltage: 300/500 V. Available from 2 to 34 cores, 0.5mm² to 1.5mm².
AGKABEL GRUPPE LIMITED presents the Data Cables LiYCY/EB, engineered for maximum safety and signal integrity in explosive or hazardous environments. These cables are identifiable by their special blue outer sheath, which denotes intrinsic safety. They are usable as flexible control and measuring cables to meet the requirements for the installation of electrical apparatus in hazardous areas. Note that these installations are not earthed and require a separate power circuit. The braided copper screen ensures the transmission of data signals free from electromagnetic interference (EMI). The cable is extensively oil-resistant but not suitable for laying below ground. Cores are coloured to DIN VDE 47100.
Technical Data
-
Standard: adapted to DIN VDE 0165 part 1, EN 60079-14, IEC 60079-14 sect. 12.2.2.6
-
Temperature range:
-
Flexing: -5°C to +80°C
-
Fixed installation: -30°C to +80°C
-
-
Nominal voltage U0/U: 300/500 V
-
Test voltage: 2000 V
-
Insulation resistance min.: 20 MOhm x km
-
Application: For hazardous areas. Cables with special marking (blue). Usable as flexible control and measuring cables to meet the requirements for the installation of electrical apparatus. These installations are not earthed and require a separate power circuit. Not suitable for laying below ground. The braided copper screen ensures the transmission of data signals and is free from interference. Extensively oil-resistant.
Technical Specifications Table
| Part N° | N° of cores x cross-sec mm² | Outer diameter ca. mm | Copper weight kg/km | Weight ca. kg/km |
|---|---|---|---|---|
| 0.5mm² Cores | ||||
| 11105001 | 2X0,5 | 5,9 | 36,00 | 49,00 |
| 11105002 | 3X0,5 | 6,2 | 43,00 | 58,00 |
| 11105003 | 4X0,5 | 6,6 | 49,00 | 70,00 |
| 11105004 | 5X0,5 | 7,1 | 57,00 | 80,00 |
| 11105006 | 7X0,5 | 7,6 | 69,00 | 99,00 |
| 11105007 | 12X0,5 | 7,6 | 107,00 | 147,00 |
| 11105008 | 16X0,5 | 10,5 | 129,00 | 184,00 |
| 11105009 | 18X0,5 | 11,0 | 141,00 | 203,00 |
| 11105010 | 20X0,5 | 11,4 | 161,00 | 220,00 |
| 0.75mm² Cores | ||||
| 11105012 | 2X0,75 | 5,9 | 43,00 | 50,00 |
| 11105013 | 3X0,75 | 6,2 | 52,00 | 64,00 |
| 11105014 | 4X0,75 | 7,1 | 61,00 | 77,00 |
| 11105015 | 5X0,75 | 7,7 | 72,00 | 93,00 |
| 11105017 | 6X0,75 | 8,3 | 85,00 | 113,00 |
| 11105080 | 7X0,75 | 8,6 | 90,00 | 130,00 |
| 11105085 | 8X0,75 | 9,4 | 110,00 | 145,00 |
| 11105019 | 12X0,75 | 10,5 | 154,00 | 187,00 |
| 11105020 | 16X0,75 | 12,0 | 183,00 | 249,00 |
| 1.0mm² Cores | ||||
| 11105027 | 2X1 | 7,4 | 51,00 | 74,00 |
| 11105029 | 3X1 | 7,9 | 70,00 | 89,00 |
| 11105031 | 4X1 | 8,7 | 80,00 | 107,00 |
| 11105073 | 5X1 | 9,2 | 95,00 | 132,00 |
| 11105032 | 7X1 | 10,0 | 120,00 | 158,00 |
| 11105033 | 10X1 | 13,5 | 165,00 | 215,00 |
| 11105034 | 12X1 | 13,3 | 185,00 | 254,00 |
| 11105035 | 16X1 | 15,5 | 220,00 | 330,00 |
| 1.5mm² Cores | ||||
| 11105040 | 2X1,5 | 8,0 | 65,00 | 86,00 |
| 11105042 | 2X1,5 | 8,5 | 90,00 | 107,00 |
| 11105075 | 4X1,5 | 9,2 | 110,00 | 129,00 |
| 11105081 | 5X1,5 | 10,0 | 125,00 | 150,00 |
| 11105046 | 7X1,5 | 10,8 | 159,00 | 192,00 |
| 11105047 | 12X1,5 | 15,0 | 268,00 | 315,00 |
| 11105049 | 18X1,5 | 16,8 | 373,00 | 450,00 |
| 11105050 | 20X1,5 | 17,8 | 385,00 | 500,00 |
(Further dimensions available on request.)
Factory Overview
Packaging & Shipping


❓ Frequently Asked Questions (FAQ)
1. What are the primary applications for these cables?
They are designed for hazardous areas as flexible control and measuring cables for the installation of electrical apparatus. The special blue marking identifies them for intrinsic safety applications.
2. What is the significance of the blue outer sheath?
The blue outer sheath is a standard identification for intrinsically safe circuits, signaling that the cable is suitable for use in hazardous areas where explosive atmospheres may be present.
3. What is the temperature range of these cables?
-
Flexing: -5°C to +80°C
-
Fixed installation: -30°C to +80°C
4. What is the voltage rating of these cables?
The nominal voltage is 300/500 V and the test voltage is 2000 V.
5. What standards do these cables comply with?
They comply with DIN VDE 0165 part 1, EN 60079-14, and IEC 60079-14.
6. Are these cables suitable for underground installation?
No, they are not suitable for laying below ground.
7. What is the purpose of the copper screen?
The braided copper screen ensures that data signals are transmitted free from electromagnetic interference (EMI), which is critical for accurate measurement and control in sensitive environments.
8. What sizes and core configurations are available?
Available from 2 to 34 cores, with conductor sizes ranging from 0.5mm² to 1.5mm².