2XSEYBY-FR & A2XSEYBY-FR 6/10 kV Flame Retardant Armoured Cable – IEC 60502-2

The 2XSEYBY-FR and A2XSEYBY-FR 6/10 kV cables deliver dependable power transfer and distribution for medium voltage networks. Constructed with copper or aluminum conductors, XLPE insulation, galvanized steel tape armour, and flame retardant PVC sheaths, they offer exceptional fire safety and mechanical protection. Because they meet IEC 60502-2 standards and are RoHS compliant, they provide a safe and reliable solution for urban networks, substations, and industrial plants.

Application
2XSEYBY-FR and A2XSEYBY-FR medium voltage three-core cables provide reliable transfer and distribution of electrical power in power supply networks. They operate efficiently with a nominal voltage of Uo/U 6/10 kV and a frequency of 50 Hz, in urban and district electrical networks. Furthermore, installers use them for the electrical supply of transformer substations, small and medium industrial plants, electric power stations, and industrial systems. Because of their robust design, they are suitable for fixed assembly in lines with unlimited difference levels, indoor installations, cable ducts, conduits, and shafts. Additionally, they perform reliably on shelves and grilles, directly underground in ditch, and outdoor under shelters.

Cable construction
This cable strictly adheres to IEC 60502-2 and IEC 60332-3 standards. It features copper and aluminum stranded compacted conductors according to IEC 60228 class 2. The inner semi-conductive layer, insulation, and outer semi-conductive layer all use XLPE or semi-conductive XLPE compounds. The metal screen uses Cu tapes laid with overlap over each phase. The cable assembly features three insulated and screened phases twisted with fillings and tape support. The inner sheath uses an extruded PVC compound flame retardant. The armour consists of galvanized steel tapes (galvanized steel-tapes) and a PVC compound flame retardant sheath. The color is black or red. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to IEC 60228. The maximum conductor temperature reaches 90 °C continuous. During an overload, it can withstand 130 °C for 100% per year max. In a short circuit, it withstands 250 °C for a maximum of 5 seconds. It operates at a nominal voltage of Uo/U 6/10 kV, while the highest system voltage is 6/10 kV and 12 kV. Test voltage is AC (+) – 5 min for 6/10 kV (21 kV), or DC (-) – 15 min. The level of partial discharge at 2Uo is max. 5 pC. The minimum bending radius is 15 times the cable diameter. The temperature of laying is no less than -5 °C. The temperature of explosion is -30 to 50 °C. Testing follows IEC 60502-2 and DIN VDE 0276-620. Furthermore, it passes the flame retardant test according to IEC 60332-3 Cat. A and IEC 60332-1.

Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data 2XSEYBY-FR, A2XSEYBY-FR 6/10 kV

Number of conductors and nominal cross section Thickness of insulation Thickness of sheath Nominal cross section of screen Cable diameter approx. 2XSEYBY-FR Mass of Cu approx. 2XSEYBY-FR Cable weight approx. A2XSEYBY-FR Mass of Al approx. A2XSEYBY-FR Cable weight approx.
N x mm² mm mm mm² mm kg/km kg/km kg/km kg/km
6/10 kV
3×35 m/16 3,4 2,5 16 48,4 1010 3639 298 2963
3×50 m/16 3,4 2,6 16 51,0 1363 4203 404 3272
3×70 m/16 3,4 2,7 16 55,3 1968 4844 584 3612
3×95 m/16 3,4 2,8 16 59,3 2732 6459 809 4429
3×120 m/16 3,4 2,9 16 62,5 3440 7039 1023 4848
3×150 m/25 3,4 3,0 25 66,2 4245 8151 1257 5435
3×185 m/25 3,4 3,2 25 70,5 5311 9371 1579 6082
3×240 m/25 3,4 3,4 25 76,5 6981 12001 2071 7371
3×300 m/25 3,4 3,7 25 83,2 8861 15023 2589 9255

Note: Other core configuration and special constructions manufactured upon request.

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the 2XSEYBY-FR and A2XSEYBY-FR cables?
A:- They are designed for the transfer and distribution of electrical power in urban and district electrical networks and for the electrical supply of transformer substations, small and medium industrial plants, and power stations.

Q:- What are the nominal voltage levels available for this cable?
A:- The cables are available at a nominal voltage level of Uo/U 6/10 kV, operating at a frequency of 50 Hz.

Q:- What standards does the cable construction follow?
A:- The construction adheres to IEC 60502-2 and IEC 60332-3 standards, and the conductor complies with IEC 60228 class 2.

Q:- What type of conductor and insulation does it use?
A:- It uses Cu and Al stranded compacted conductors with XLPE insulation.

Q:- What type of armour and screen are used?
A:- The metal screen uses Cu tapes laid with overlap over each phase, and the armour consists of galvanized steel tapes.

Q:- What are the key fire safety features of this cable?
A:- It features an extruded PVC flame retardant inner sheath and a PVC flame retardant outer sheath, passing the IEC 60332-3 Cat. A and IEC 60332-1 flame tests.

Q:- What is the maximum operating and short-circuit temperature?
A:- The maximum operating temperature is 90°C continuous, and it can withstand a short circuit temperature of 250°C for a maximum of 5 seconds.

Q:- What is the maximum partial discharge level?
A:- The level of partial discharge at 2Uo is max. 5 pC.

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 15 times the cable diameter (15x D cable).

Q:- What are the temperature limits for laying and explosion?
A:- The temperature of laying is no less than -5°C, and the temperature of explosion is -30 to 50°C.