2XBH & A2XBH 0.6/1 kV Halogen-Free Flame Retardant Armoured Cable – IEC 60502-1

The 2XBH and A2XBH 0.6/1 kV cables deliver dependable power distribution for safety-critical environments like power stations, airports, and public buildings. Constructed with copper or aluminum conductors, XLPE insulation, steel tape armour, and a black halogen-free flame retardant outer sheath, they offer exceptional fire safety and mechanical protection. Because they meet IEC 60502-1 and VDE 0276-604 standards and are CE/RoHS compliant, they provide a safe and reliable solution for installations indoors, in air, or in concrete.

Application
2XBH and A2XBH cables provide reliable power distribution with low halogen fire smoke emission and corrosion at fire conditions. Because of these critical safety features, installers use them in electrical installations for a nominal voltage of 0.6/1 kV. Furthermore, they are essential for important objects like power stations (nuclear, thermal), transformer substations, metro systems, and airports. Additionally, they are ideal for public buildings, hospitals, theaters, cinemas, and commercial centers where the safety of people and material values must be guaranteed. The cables can be laid indoors, in air, or in concrete. However, direct laying underground or in water is not allowed.

Cable construction
This cable strictly adheres to IEC 60502-1 and VDE 0276-604 (HD 604 S1) standards. It features copper or aluminum solid or stranded wires class 1 or 2 according to IEC 60228. The insulation uses an XLPE compound. Core identification follows VDE 0276-604. A halogen-free compound forms the inner sheath. The armour consists of two steel tapes or two galvanized steel tapes. Finally, a black halogen-free compound, flame retardant type HM4 (LTS 1) sheath protects the entire assembly. Furthermore, this product is both RoHS and CE compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance according to IEC 60228. The operating temperature reaches 90 °C continuous. During an overload, it can withstand 130 °C for 100% per year max. In a short circuit, it withstands 250 °C for a maximum of 5 seconds. It operates at a nominal voltage of Uo/U 0.6/1 kV, while the highest system voltage is 1.2 kV. Test voltage is AC 50 Hz 4.0 kV. Installers must respect a minimum bending radius of 15 times the cable diameter (15x D cable) for single angle cores, or 12 times (12x D cable) for multi-core cables. The temperature of laying is no less than 0 °C. The temperature of explosion is -30 to 70 °C. Testing follows IEC 60502-1 and VDE 0276-604 / (IEC 332-3/C and B). The corrosion of combustion gases and conductivity has a pH of min. 4.3 and max. 100 µS/cm. The density of smoke gases follows VDE 0472-816 (IEC 61034-1 and 2).

Color coding
Clear color coding ensures safe and accurate wiring. Single core cables are black or yellow/green. Double core cables feature blue and brown, or yellow-green and black. 3-core cables use brown, black, and grey, or yellow/green, blue, and brown. 4-core cables use blue, brown, black, and grey, or yellow/green, brown, black, and grey. 5-core cables use blue, brown, black, grey, and black, or yellow/green, blue, brown, black, and grey. Multiple core cables use black with number marks on cores or black with number marks on cores and a yellow/green core in the outer cover.

Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data 2XBH

Number of wires and nominal cross section Type of conductor Cable diameter approx. Mass of Cu approx. Mass of cable approx.
N x mm² mm kg/km kg/km
5×4,0 re 19,6 187 590
5×6,0 re 21,0 279 715
5×10 rm 24,8 470 1095
5×16 rm 25,7 744 1270
5×25 rm 31,9 1213 1925
5×35 rm 36,1 1683 2555
5×50 rm 40,1 2271 3390
5×70 rm 45,3 3280 4455
5×95 sm 50,5 4333 5255
8×1,5 re 18,2 114 485
10×1,5 re 19,9 142 575
12×1,5 re 21,1 171 615
16×1,5 re 21,9 199 675
19×1,5 re 22,1 227 725
24×1,5 re 24,5 284 855
30×1,5 re 26,0 355 980
37×1,5 re 26,1 341 1005
7×2,5 re 18,0 163 505
10×2,5 re 21,5 232 765
12×2,5 re 22,0 279 780
16×2,5 re 23,9 372 930
19×2,5 re 25,0 441 1005
21×2,5 re 26,1 488 1095
24×2,5 re 28,6 557 1295
30×2,5 re 30,2 697 1485
37×2,5 re 32,3 859 1700
7×4,0 re 22,9 299 825
7×6,0 re 25,2 391 1010
7×10 re 26,0 559 1270
8×4,0 re 19,5 447 1045
10×6,0 re 27,4 559 1270

Construction data A2XBH

Number of wires and nominal cross section Type of conductor Cable diameter approx. Mass of Al approx. Mass of cable approx.
N x mm² mm kg/km kg/km
5×6,0 re 17,5 35 505
5×10 re 19,1 56 480
5×16 rm 21,1 84 605
5×25 rm 25,1 144 815
5×35 rm 27,3 199 940
5×50 rm 31,0 269 1180
5×70 rm 35,0 390 1440
5×95 sm 38,6 560 1455
5×120 sm 42,7 809 2080
3×10+4 re 19,2 110 555
3×16 re 19,8 135 580
3×25 rm 23,0 210 790
3×35 rm 25,8 290 870
3×50+25 sm 30,1 343 1135
3×70+35 sm 35,6 474 1445
3×95+50 sm 39,5 739 1970
3×120+70 sm 43,0 844 2235
3×150+70 sm 45,6 1218 2620
3×185+95 sm 54,5 1848 3180
3×240 sm 60,9 2412 4100
3×35+16 sm 30,0 143 900
3×70+35 rm 35,6 474 1445
3×95+50 rm 39,5 739 1970
3×120+70 rm 43,0 844 2235
3×150+70 rm 45,6 1218 2620
3×240 sm 60,9 2412 4100
4×6 re 19,6 46 560
4×10 re 21,5 111 745
4×16 rm 23,8 112 880
4×25 rm 29,0 282 1330
4×35 rm 31,9 290 1580
4×50 sm 38,2 479 1910
4×70 sm 42,4 554 2380
4×95 sm 47,2 671 2810
4×120 sm 50,2 887 3325
4×150 sm 54,8 1115 3630
4×185 sm 60,9 1344 4280
4×240 sm 60,9 2762 4940

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the 2XBH and A2XBH cables?
A:- They are used in electrical installations for a nominal voltage of 0.6/1 kV, particularly in safety-critical environments like power stations, metro systems, airports, and public buildings.

Q:- What are the key fire safety features of this cable?
A:- It is halogen-free, flame retardant, and emits low smoke and low-corrosion gases during a fire, passing the IEC 332-3/C and B tests.

Q:- What standards does the cable construction follow?
A:- The construction adheres to IEC 60502-1 and VDE 0276-604 (HD 604 S1) standards, and the conductor complies with IEC 60228.

Q:- What type of conductor and insulation does it use?
A:- It uses Cu or Al solid or stranded wires (class 1 or 2) with XLPE insulation.

Q:- What kind of armour protects this cable?
A:- The cable features an armour made of two steel tapes or two galvanized steel tapes.

Q:- Where can this cable be installed?
A:- The cables can be laid indoors, in air, or in concrete. However, direct laying underground or in water is not allowed.

Q:- What is the rated voltage and maximum conductor temperature?
A:- The rated voltage is 0.6/1 kV, and the continuous operating temperature is 90°C.

Q:- What is the short-circuit temperature limit?
A:- It can withstand a short circuit temperature of 250°C for a maximum of 5 seconds.

Q:- What is the test voltage for this cable?
A:- The test voltage is AC 50 Hz 4.0 kV.

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 15 times the cable diameter (15x D cable) for single angle cores, or 12 times (12x D cable) for multi-core cables.