RD-Y(St)Y & RE-2Y(St)Y PiMF Industrial Electronic Cables – DIN VDE 0815

The RD-Y(St)Y and RE-2Y(St)Y PiMF cables deliver dependable signal transmission for measurement and control technology. Constructed with copper conductors, PVC or PE insulation, static screens, and twisted pairs, they offer excellent protection against electrical interference and crosstalk. Because they meet DIN VDE 0815 standards, they provide a safe and reliable solution for control rooms, industrial plants, and power stations.

Application
RD-Y(St)Y and RE-2Y(St)Y PiMF cables provide reliable signal transmission for measurement and control technology. Because they feature static screens and twisted pairs, installers use them in control rooms of industrial plants and power stations. Furthermore, the static screen protects transmission circuits against outer electrical interferences, and the twisted pairs lead to good crosstalk attenuation values in a unit. Additionally, these cables serve for the transmission of analog and digital signals up to frequencies of approx. 10 kHz (Max-Termi-Point capable). Consequently, they deliver consistent performance for fixed installation in buildings.

Cable construction
These cables strictly adhere to DIN VDE 0815 standards. They feature copper conductors. The insulation uses PVC compounds for RD variants and PE for RE variants. A static screen (aluminum foil with a drain wire) provides protection against external interference. The outer sheath is made of PVC compound. The PiMF designation indicates that the pairs are individually screened (PIMF) for maximum crosstalk protection. A blue outer jacket is also available for intrinsically safe installations.

Technical Data
The cables deliver consistent performance under specific conditions. The temperature range is -5 °C to +50 °C for flexing applications and -30 °C to +70 °C for fixed installations. The test voltage is 2000 V (core/core) and 1000 V (core/screen).

Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

RD-Y(St)Y / RD-Y(St)Yv / RD-Y(St)YY

Part N° N° of cores x cross-sec mm² Outer diameter ca. mm Copper weight kg/km Weight ca. kg/km
11301026 2X2X0,5 6,0 25,00 60,00
11301027 4X2X0,5 8,0 45,00 95,00
11301028 8X2X0,5 11,5 85,00 157,00
11301029 12X2X0,5 12,0 125,00 229,00
11301030 16X2X0,5 13,7 165,00 290,00
11301001 20X2X0,5 Bd 15,0 205,00 380,00
11301002 24X2X0,5 Bd 16,3 245,00 422,00
11301003 28X2X0,5 Bd o. r. 285,00 530,00
11301004 32X2X0,5 Bd 22,0 325,00 535,00
11301005 36X2X0,5 Bd o. r. 365,00 640,00
11301006 40X2X0,5 Bd 21,8 405,00 700,00
11301007 44X2X0,5 Bd o. r. 445,00 760,00
11301008 48X2X0,5 Bd 23,0 485,00 796,00
11301009 52X2X0,5 Bd o. r. 525,00 910,00
11301010 56X2X0,5 Bd o. r. 565,00 975,00
11301011 60X2X0,5 Bd o. r. 605,00 1.045,00
11301012 64X2X0,5 Bd o. r. 645,00 1.110,00
11301013 80X2X0,5 Bd 28,8 805,00 1.340,00
11301014 96X2X0,5 Bd 30,5 965,00 1.500,00
11301015 2X2X1 Bd 10,0 51,00 120,00
11301016 4X2X1 Bd 11,0 91,00 160,00
11301017 8X2X1 Bd 15,0 171,00 310,00
11301018 12X2X1 Bd 17,5 252,00 420,00
11301019 16X2X1 Bd 20,5 332,00 560,00
11301020 20X2X1 Bd 22,5 413,00 670,00
11301021 24X2X1 Bd 24,5 493,00 810,00
11301022 32X2X1 Bd 27,5 654,00 1.040,00
11301023 40X2X1 Bd 31,0 816,00 1.290,00
11301024 48X2X1 Bd 33,5 977,00 1.520,00
11301025 80X2X1 Bd 42,0 1.617,00 2.440,00
11311001 2X2X0,5 9,0 25,00 95,00
11311002 8X2X0,5 13,0 85,00 202,00

RD-Y(St)YY / RE-2Y(St)Y / RE-2Y(St)Yv / RE-2Y(St)Yv PiMF

Part N° N° of cores x cross-sec mm² Outer diameter ca. mm Copper weight kg/km Weight ca. kg/km
11302001 2X2X0,5 Bd 6,0 25,00 55,00
11302003 4X2X0,5 Bd 8,0 45,00 91,00
11302005 8X2X0,5 Bd 11,5 85,00 158,00
11302007 12X2X0,5 Bd 12,0 125,00 210,00
11302009 16X2X0,5 Bd 13,7 165,00 280,00
11302011 20X2X0,5 Bd 15,0 205,00 340,00
11302013 24X2X0,5 Bd 16,3 245,00 392,00
11302015 28X2X0,5 Bd 18,2 285,00 425,00
11302017 32X2X0,5 Bd 20,5 325,00 453,00
11302019 36X2X0,5 Bd 21,8 365,00 510,00
11302021 40X2X0,5 Bd 21,8 405,00 640,00
11302023 44X2X0,5 Bd 22,5 445,00 690,00
11302025 48X2X0,5 Bd 23,0 485,00 750,00
11302027 52X2X0,5 Bd 23,8 525,00 795,00
11302029 56X2X0,5 Bd 24,5 565,00 845,00
11302031 60X2X0,5 Bd 25,4 605,00 899,00
11302033 64X2X0,5 Bd 26,5 645,00 959,00
11302035 80X2X0,5 Bd 28,8 805,00 1.200,00
11302037 96X2X0,5 Bd 30,5 965,00 1.570,00
11305001 1x2x0,5 8,2 15,00 80,00
11305026 2x2x0,5 10,2 30,00 122,00
11305018 4x2x0,5 10,8 50,00 135,00
11305043 6x2x0,5 12,6 70,00 190,00
11305027 8x2x0,5 13,3 90,00 200,00
11305028 10x2x0,5 14,4 110,00 225,00
11305029 12x2x0,5 15,0 130,00 260,00
11305030 16x2x0,5 16,8 170,00 320,00
11305031 20x2x0,5 18,7 210,00 380,00
11305032 24x2x0,5 20,5 250,00 465,00
11305033 36x2x0,5 24,3 370,00 650,00
11305034 48x2x0,5 27,5 490,00 840,00
11305042 2x2x0,75 11,5 31,50 140,00
11305035 1x2x1,3 10,0 34,00 87,00
11305036 2x2x1,3 11,7 62,00 61,00
11305037 4x2x1,3 13,5 114,00 230,00
11305038 8x2x1,3 17,5 218,00 343,00
11305039 12x2x1,3 19,3 322,00 515,00
11305040 16x2x1,3 22,0 426,00 656,00
11305041 24x2x1,3 26,5 684,00 952,00
11305042 1x3x1,3 9,7 44,00 116,00
11307001 1x2x0,5 7,3 15,00 60,00
11307007 2x2x0,5 9,8 30,00 110,00
11307008 4x2x0,5 11,5 50,00 150,00
11307009 8x2x0,5 15,0 90,00 191,00
11307028 20x2x0,5 18,5 210,00 385,00
11307029 24x2x0,5 20,2 250,00 468,00
11307010 1x2x0,75 7,7 25,00 70,00
11307027 2x2x0,75 10,6 35,00 123,00
11307011 4x2x0,75 11,8 70,00 170,00
11307020 6x2x0,75 14,5 92,00 187,00
11307025 8x2x0,75 14,6 125,00 258,00
11307012 12x2x0,75 16,9 190,00 355,00
11307030 50x2x0,75 28,0 710,00 1.200,00
11307015 1x3x1,3 7,7 44,00 66,00
11307014 4x2x1,3 13,3 114,00 230,00
11307013 8x2x1,3 16,8 218,00 375,00
11307019 12x2x1,3 20,5 322,00 488,00
11307021 24x2x1,3 29,4 697,00 1.104,00
11307017 48x2x1,3 34,2 1.368,00 1.834,00

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of these instrumentation cables?
A:- They are used in measurement and control technology, particularly in control rooms of industrial plants and power stations.

Q:- What is the function of the static screen and twisted pairs?
A:- The static screen protects against outer electrical interferences, while the twisted pairs lead to good crosstalk attenuation values.

Q:- What standards do these cables comply with?
A:- They comply with DIN VDE 0815 standards.

Q:- What is the maximum frequency for signal transmission?
A:- They are suitable for transmitting analog and digital signals at frequencies up to approx. 10 kHz (Max-Termi-Point capable).

Q:- What does the PiMF designation indicate?
A:- PiMF indicates that the pairs are individually screened, providing maximum protection against crosstalk and interference.

Q:- What is the test voltage for these cables?
A:- The test voltage is 2000 V (core/core) and 1000 V (core/screen).

Q:- What is the temperature range for these cables?
A:- The temperature range is -5°C to +50°C for flexing and -30°C to +70°C for fixed installation.

Q:- What is the difference between the RD and RE variants?
A:- RD variants typically use PVC insulation, while RE variants use PE insulation for lower capacitance and better high-frequency performance.

Q:- What is the largest configuration available in the provided tables?
A:- The largest configuration shown is 96X2X0,5 Bd in the RD-Y(St)Y series.

Q:- Are other dimensions available besides those listed?
A:- Yes, further dimensions are available upon request.

Reviews

There are no reviews yet.

Be the first to review “RD-Y(St)Y & RE-2Y(St)Y PiMF Industrial Electronic Cables – DIN VDE 0815”

Your email address will not be published. Required fields are marked *