FRT-XOL & FRT-XOSL Flame Retardant Instrumentation Cables
These flame retardant instrumentation cables are engineered for multi-core signal transmission in critical industrial environments. They feature plain annealed copper conductors with XLPE or XLEVA insulation and an aluminium/polyester tape screen with a tinned drain wire for excellent interference protection. The LSZH outer sheath ensures safety with low smoke and zero halogen emissions, while the armoured version adds galvanized steel wire for mechanical protection. Available in various configurations, they are compliant with BS 5308 and BS 6724 standards.
These flame retardant instrumentation cables are specifically designed for multi-core signal transmission in demanding industrial environments. Because they are manufactured with Plain Annealed Copper conductors and XLPE or XLEVA insulation, they are exceptionally reliable for critical control and instrumentation circuits. Furthermore, the aluminium/polyester tape screen with a tinned drain wire provides excellent protection against electromagnetic interference, ensuring signal integrity. Consequently, these cables are highly suitable for power stations, process control systems, and manufacturing plants where safety and performance are paramount.
The cable structure features a plain annealed copper conductor with Class 2 or Class 5 stranding, insulated with either XLPE or XLEVA compound. The screened construction includes an aluminium/polyester tape with a 0.5mm² tinned drain wire, while the armoured version adds galvanized steel wire for mechanical protection. Finally, the assembly is protected by a robust LSZH (Low Smoke Zero Halogen) compound sheath in black, with white number-coded insulation for easy identification.
Technical Data & Construction Overview:
-
Reference Standard: BS 5308 / BS 7211 / BS 6724
-
Test Standard: IEC 60332-3, BS 4066, IEC 60754, BS 6425, IEC 61034, BS 7622-Part-2
-
Voltage Uo/U: 300/500V
-
Conductor Stranding: Class 2 and 5
-
Operating Temperature: (a) Max 90°C for XLPE; (b) Max 110°C for XLEVA
-
Minimum Bending Radius: 8D for unarmoured cable; 10D for armoured cable
Construction Data
| Size | FRT-XOL (Unarmoured) | FRT-XOSL (Armoured) | ||||||
|---|---|---|---|---|---|---|---|---|
| Nominal Conductor Area (mm²) | No. & Dia. of Wires (no./mm) | Radial Thick. of Insulation (mm) | Cable Overall Dia. (mm) | Approx. Weight (kg/km) | Cable Overall Dia. (mm) | Armour Wire Dia. (mm) | Cable Overall Dia. (mm) | Approx. Weight (kg/km) |
| 2 x 0.5 | 16 / 0.20 | 0.6 | 7.0 | 50 | 7.0 | 0.90 | 11.4 | 237 |
| 3 x 0.5 | 16 / 0.20 | 0.6 | 7.3 | 59 | 7.3 | 0.90 | 11.7 | 254 |
| 4 x 0.5 | 16 / 0.20 | 0.6 | 7.9 | 69 | 7.9 | 0.90 | 12.3 | 278 |
| 6 x 0.5 | 16 / 0.20 | 0.6 | 9.3 | 94 | 9.3 | 0.90 | 13.9 | 345 |
| 10 x 0.5 | 16 / 0.20 | 0.6 | 11.9 | 147 | 11.9 | 0.90 | 16.7 | 470 |
| 20 x 0.5 | 16 / 0.20 | 0.6 | 14.9 | 253 | 14.9 | 1.25 | 20.6 | 759 |
| 40 x 0.5 | 16 / 0.20 | 0.6 | 20.1 | 444 | 20.1 | 1.60 | 26.7 | 1229 |
| 2 x 0.75 | 24 / 0.20 | 0.6 | 7.3 | 57 | 7.3 | 0.90 | 11.7 | 251 |
| 3 x 0.75 | 24 / 0.20 | 0.6 | 7.7 | 68 | 7.7 | 0.90 | 12.1 | 272 |
| 4 x 0.75 | 24 / 0.20 | 0.6 | 8.3 | 81 | 8.3 | 0.90 | 12.9 | 310 |
| 6 x 0.75 | 24 / 0.20 | 0.6 | 9.9 | 114 | 9.9 | 0.90 | 14.5 | 379 |
| 10 x 0.75 | 24 / 0.20 | 0.6 | 12.7 | 179 | 12.7 | 0.90 | 17.5 | 522 |
| 20 x 0.75 | 24 / 0.20 | 0.6 | 16.0 | 311 | 16.0 | 1.25 | 21.7 | 858 |
| 40 x 0.75 | 24 / 0.20 | 0.6 | 21.7 | 555 | 21.7 | 1.60 | 28.5 | 1420 |
| 2 x 1.5 | 7 / 0.53 | 0.6 | 8.3 | 78 | 8.3 | 0.90 | 12.9 | 290 |
| 3 x 1.5 | 7 / 0.53 | 0.6 | 8.9 | 103 | 8.9 | 0.90 | 13.5 | 345 |
| 4 x 1.5 | 7 / 0.53 | 0.6 | 9.7 | 125 | 9.7 | 0.90 | 14.3 | 377 |
| 6 x 1.5 | 7 / 0.53 | 0.6 | 11.7 | 163 | 11.7 | 0.90 | 16.3 | 490 |
| 10 x 1.5 | 7 / 0.53 | 0.6 | 14.7 | 285 | 14.7 | 1.25 | 20.4 | 773 |
| 20 x 1.5 | 7 / 0.53 | 0.6 | 18.7 | 504 | 18.7 | 1.60 | 25.3 | 1262 |
| 40 x 1.5 | 7 / 0.53 | 0.6 | 26.0 | 935 | 26.0 | 1.60 | 31.6 | 1968 |
Note: Other conductor sizes & core confi gurations are available upon request.
Factory Overview
Packaging & Shipping
Frequently asked questions and answer (Q:- A:-)
Q:- What is the primary application of these instrumentation cables?
A:- They are designed for multi-core signal transmission in demanding industrial environments.
Q:- What type of conductor is used?
A:- They feature Plain Annealed Copper conductors.
Q:- What is the reference standard for these cables?
A:- The reference standards are BS 5308, BS 7211, and BS 6724.
Q:- What is the voltage rating?
A:- The voltage rating is Uo/U 300/500V.
Q:- What is the maximum operating temperature for XLPE insulation?
A:- The maximum operating temperature for XLPE is 90°C.
Q:- What is the maximum operating temperature for XLEVA insulation?
A:- The maximum operating temperature for XLEVA is 110°C.
Q:- What is the minimum bending radius for unarmoured cables?
A:- The minimum bending radius is 8D (8 times the cable diameter).
Q:- What is the minimum bending radius for armoured cables?
A:- The minimum bending radius is 10D (10 times the cable diameter).
Q:- What type of screen is used?
A:- An Aluminium/Polyester Tape screen with a 0.5mm² Tinned Drain Wire is used.
Q:- What material is used for the outer sheath?
A:- The outer sheath is made of LSZH (Low Smoke Zero Halogen) compound in black.




Reviews