MKKBP 4x4x1.2 + 15x4x1.2 PE Sheathed Combined HF/LF Trunk Cable – BDS 5052-90
The MKKBP 4x4x1.2 + 15x4x1.2 cable delivers dependable signal transmission for trunk cable communication networks and telephone exchanges. Constructed with bare copper conductors, paper string insulation, a lead-containing sheath, steel tape armour, and a protective PE sheath, it combines 4 HF quads and 15 LF quads for simultaneous high and low-frequency transmission. Because it meets BDS 5052-90 standards, it provides a reliable and robust solution for direct laying in ditches.
Application
MKKBP cables provide reliable signal transmission for the construction of trunk cable communication networks and connection lines between automatic telephone exchanges. Because they feature steel tape armour and combine both high-frequency (HF) and low-frequency (LF) quads, installers use them to transmit HF and LF signals simultaneously at frequencies up to 252 kHz. Furthermore, they are suitable for laying in ditches in all types of grounds where there is less force of strain and inclined terrain less than 45°. However, using them for high voltage power installations is not permitted.
Cable construction
This cable strictly adheres to BDS 5052-90 standards. It features a bare copper conductor with a diameter of 1.2 mm. The insulation uses paper string insulation, over which a paper tape is applied. Four wires are twisted into a quad. The cable includes 4 HF quads and 15 LF quads, which are twisted into layers and wound around them. A lead-containing sheath (with an antimony of 0.4 to 0.6%) forms the pad, followed by bitumen and impregnated cable paper. The armour consists of two steel tapes, and a protective PE sheath with low density and 2.5% carbon black completes the assembly.
Technical Data
The cable delivers consistent performance under specific conditions. It maintains a resistance of side circuit at 31.7 Ω/km and a conductor diameter of 1.2 mm. The ohmic asymmetry of HF quads is max. 0.1 Ω/425m, and the insulation resistance is min. 12,000 MΩ.km. The mutual capacitance at 800 Hz is 26.5 nF/km for HF quads and 35 nF/km for LF quads. Attenuation near the end between all side-circuits of HF quads at 252 kHz is 62 dB/425 (90% of all combinations) and 57.6 dB/425 (100% of all combinations). Protection of far end between all side-circuits of HF quads at 252 kHz is 70 dB/425 (90% of all combinations) and 66 dB/425 (100% of all combinations). Test voltage is 50 Hz, 2 min for 1000 V (wire-wire) and 2000 V (wire-sheath). The operating voltage peak value is 300 V. The temperature range is -5 °C to +50 °C (laying and installing) and -40 °C to +70 °C (exploitation and storage). The minimum bending radius is 20 times the cable diameter.
Color coding
The color coding features side circuit 1 (a-wire: white, b-wire: red) and side circuit 2 (a-wire: green, b-wire: blue). In each layer, there is a quad with a supporting spiral and an inscription of the counting direction “yellow” in the supporting spiral.
Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.
Construction data MKKBP 4x4x1.2 + 15x4x1.2
| Cross section | Number of quads in the layers (1st layer / 2nd layer) | Outer diameter approx. | Copper weight | Cable weight approx. |
|---|---|---|---|---|
| mm | kg/km | kg/km | ||
| 4x4x1.2+15x4x1.2 | 4 HF quads / 15 LF quads | 39,9 | 807 | 3654 |
Factory Overview
Packaging & Shipping
Frequently asked questions and answer ( Q:- A:- )
Q:- What is the primary application of the MKKBP cable?
A:- It is used for trunk cable communication networks and connection lines between automatic telephone exchanges, specifically designed for direct laying in ditches.
Q:- What are the key features of this combined cable?
A:- It combines 4 high-frequency (HF) quads and 15 low-frequency (LF) quads in a single steel tape armoured cable with a protective PE sheath, providing comprehensive signal transmission and robust mechanical protection.
Q:- What standards does the cable construction follow?
A:- The construction adheres to BDS 5052-90 standards.
Q:- What type of conductor and insulation does it use?
A:- It uses a bare copper conductor with a diameter of 1.2 mm and paper string insulation with an outer paper tape.
Q:- What is the temperature range for this cable?
A:- The temperature range is -5°C to +50°C for laying and installing, and -40°C to +70°C for exploitation and storage.
Q:- What is the mutual capacitance of this cable?
A:- The mutual capacitance at 800 Hz is 26.5 nF/km for HF quads and 35 nF/km for LF quads.
Q:- What is the test voltage for this cable?
A:- The test voltage is 50 Hz, 2 min for 1000 V (wire-wire) and 2000 V (wire-sheath).
Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 20 times the cable diameter (20 x D cable).
Q:- What is the operating voltage peak value?
A:- The operating voltage peak value is 300 V.
Q:- Is this cable permitted for high voltage power installations?
A:- No, the use of these cables for high voltage power installations is not permitted.