SVVn/A 0.6/1 kV Flame Retardant Power Cable – FN KI 02.001
The SVVn/A 0.6/1 kV cable delivers dependable power distribution for industrial and commercial installations. Constructed with copper conductors, PVC insulation, a flame retardant filling, and a black flame retardant PVC outer sheath, it offers exceptional fire safety. Because it meets FN KI 02.001-96 standards, passes the BDS IEC 332-3/C2 Category A flame test, and is RoHS compliant, it provides a safe and reliable solution for environments requiring non-proliferation of flames.
Application
SVVn/A cables provide reliable power transfer and distribution in networks with a nominal voltage of Uo/U 0.6/1 kV and a frequency of 50 Hz. Because they feature flame retardant materials, installers use them in surroundings that require non-proliferation of flames. Furthermore, they ensure safety in industrial and commercial installations where fire risk is a concern. Consequently, they deliver consistent performance and safety in demanding environments.
Cable construction
This cable strictly adheres to FN KI 02.001-96 standards. It features copper solid or twisted wires (class 1 or 2) that comply with BDS 904-84 (IEC 60228). The insulation uses a PVC compound according to BDS 5792-84. A filling with flame retardant properties forms the inner sheath. Finally, a black PVC flame retardant outer sheath of flame retardancy category A protects the entire assembly. Furthermore, this product is RoHS compliant.
Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance according to BDS 904-84. It operates at a rated voltage of 0.6/1 kV and undergoes a test voltage of 4 kV (alternating) and 12 kV (direct). The temperature range for laying, installing, and exploitation is -30 °C to +50 °C. The operating temperature reaches +70 °C. The short circuit temperature is +160 °C for no more than 5 seconds. Installers must respect a minimum bending radius of 10 times the cable diameter. Furthermore, it passes the flame retardant test according to BDS IEC 332-3/C2, Category A.
Color coding
Clear color coding ensures safe and accurate wiring. Conductors without a yellow/green earth core feature random colors for 1 core, brown and blue for 2 cores, brown, black, and blue for 3 cores, and blue, brown, black, and grey for 4 cores. Conductors with a yellow/green earth core feature yellow/green, blue, and brown for 3 cores, and yellow/green, brown, black, and grey for 4 cores. The neutral conductor is always blue.
Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.
Construction data SVVn/A 0.6/1 kV
| Number of wires and nominal cross-section | Form of conductor | Cable diameter approx. | Mass of Cu | Mass of cable approx. |
|---|---|---|---|---|
| N x mm² | mm | kg/km | kg/km | |
| 1 x 1,5 | re | 8,0 | 14 | 74 |
| 1 x 2,5 | re | 8,5 | 23 | 87 |
| 1 x 4,0 | re | 9,5 | 37 | 135 |
| 1 x 6,0 | re | 10,0 | 55 | 165 |
| 1 x 10 | re | 11,4 | 93 | 221 |
| 1 x 16 | re | 12,5 | 148 | 285 |
| 1 x 25 | re | 15,8 | 225 | 538 |
| 1 x 35 | re | 17,0 | 325 | 642 |
| 1 x 50 | re | 19,1 | 456 | 882 |
| 1 x 70 | re | 21,3 | 648 | 1225 |
| 1 x 95 | re | 23,6 | 885 | 1471 |
| 1 x 120 | re | 25,7 | 1120 | 1783 |
| 1 x 150 | re | 28,7 | 1378 | 2079 |
| 1 x 185 | re | 31,0 | 1703 | 2553 |
| 1 x 240 | re | 36,0 | 2208 | 3030 |
| 1 x 300 | re | 39,1 | 2765 | 3605 |
| 1 x 400 | re | 38,1 | 3680 | 4856 |
| 1 x 500 | re | 46,0 | 4600 | 5478 |
| 2 x 1,5 | re | 11,2 | 28 | 145 |
| 2 x 2,5 | re | 12,3 | 46 | 173 |
| 2 x 4,0 | re | 13,9 | 75 | 240 |
| 2 x 6,0 | re | 14,6 | 112 | 310 |
| 2 x 10 | re | 17,3 | 182 | 523 |
| 2 x 16 | re | 20,2 | 303 | 720 |
| 2 x 25 | re | 25,7 | 652 | 1256 |
| 2 x 35 | re | 27,7 | 652 | 1310 |
| 2 x 50 | re | 32,1 | 928 | 1720 |
| 2 x 70 | re | 32,1 | 1378 | 2650 |
| 2 x 95 | re | 37,9 | 1748 | 3150 |
| 3 x 1,5 | re | 12,3 | 42 | 190 |
| 3 x 2,5 | re | 13,3 | 69 | 250 |
| 3 x 4,0 | re | 14,3 | 110 | 284 |
| 3 x 6,0 | re | 15,9 | 165 | 343 |
| 3 x 10 | re | 18,1 | 275 | 642 |
| 3 x 16 | re | 20,9 | 450 | 820 |
| 3 x 25 | re | 25,7 | 700 | 1320 |
| 3 x 35 | re | 26,7 | 980 | 1738 |
| 3 x 50 | re | 30,2 | 1410 | 2435 |
| 3 x 70 | re | 31,2 | 1850 | 2823 |
| 3 x 95 | re | 38,0 | 2550 | 4098 |
| 3 x 120 | re | 38,0 | 3350 | 5345 |
| 3 x 150 | re | 41,6 | 4530 | 6655 |
| 3 x 185 | re | 48,0 | 5160 | 6860 |
| 3 x 240 | re | 51,4 | 6720 | 8000 |
| 3 x 1,5 + 1,5 | re/re | 13,2 | 56 | 235 |
| 3 x 4,0 + 2,5 | re/re | 15,8 | 132 | 435 |
| 3 x 6,0 + 4,0 | re/re | 18,8 | 202 | 536 |
| 3 x 10 + 6,0 | re/re | 21,8 | 330 | 738 |
| 3 x 16 + 10 | re/re | 23,0 | 549 | 1068 |
| 3 x 25 + 16 | rm/re | 27,0 | 850 | 1470 |
| 3 x 35 + 16 | rm/rm | 29,2 | 1131 | 1578 |
| 3 x 50 + 25 | sm/rm | 33,2 | 1680 | 2505 |
| 3 x 70 + 35 | sm/rm | 38,0 | 2280 | 2833 |
| 3 x 95 + 50 | sm/rm | 40,0 | 3090 | 4315 |
| 3 x 120 + 70 | sm/rm | 43,2 | 4010 | 5180 |
| 3 x 150 + 70 | sm/rm | 47,2 | 4880 | 5840 |
| 3 x 185 + 95 | sm/rm | 52,3 | 6070 | 7771 |
| 3 x 240 + 120 | sm/rm | 56,6 | 7840 | 9254 |
| 3 x 300 + 150 | sm/rm | 64,3 | 9928 | 12666 |
| 4 x 1,5 | re | 12,9 | 55 | 270 |
| 4 x 4,0 | re | 16,2 | 146 | 454 |
Construction data SVVn/A 0.6/1 kV
| Number of wires and nominal cross-section | Form of conductor | Cable diameter approx. | Mass of Cu | Mass of cable approx. |
|---|---|---|---|---|
| N x mm² | mm | kg/km | kg/km | |
| 4 x 6,0 | re | 17,4 | 218 | 569 |
| 4 x 10 | re | 18,2 | 363 | 710 |
| 4 x 16 | re | 21,8 | 582 | 1162 |
| 4 x 25 | rm | 28,0 | 930 | 1873 |
| 4 x 35 | rm | 30,1 | 1303 | 2190 |
| 4 x 50 | sm | 36,1 | 1837 | 2937 |
| 4 x 70 | sm | 38,1 | 2650 | 3397 |
| 4 x 95 | sm | 42,0 | 3620 | 4638 |
| 4 x 120 | sm | 45,2 | 4628 | 5504 |
| 4 x 150 | sm | 51,7 | 3554 | 6669 |
| 4 x 185 | sm | 55,0 | 3846 | 6885 |
| 4 x 240 | sm | 63,7 | 5848 | 8138 |
| 4 x 300 | sm | 64,4 | 11060 | 13722 |
Factory Overview
Packaging & Shipping
Frequently asked questions and answer ( Q:- A:- )
Q:- What is the primary application of the SVVn/A cable?
A:- It is used for the transfer and distribution of electrical power in networks with a nominal voltage of 0.6/1 kV, specifically in surroundings requiring non-proliferation of flames.
Q:- What are the key fire safety features of this cable?
A:- It features a filling with flame retardant properties and a black PVC flame retardant outer sheath (Category A), passing the BDS IEC 332-3/C2 flame test.
Q:- What standards does the cable construction follow?
A:- The construction adheres to FN KI 02.001-96 standards, and the conductor complies with BDS 904-84 (IEC 60228).
Q:- What type of conductor and insulation does it use?
A:- It uses copper solid or twisted wires (class 1 or 2) with a PVC compound insulation according to BDS 5792-84.
Q:- What is the temperature range for this cable?
A:- The temperature range for laying and exploitation is -30°C to +50°C.
Q:- What is the maximum operating and short-circuit temperature?
A:- The operating temperature is +70°C, and the short-circuit temperature is +160°C for no more than 5 seconds.
Q:- What is the test voltage for this cable?
A:- The test voltage is 4 kV (alternating) and 12 kV (direct).
Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 10 times the cable diameter (10 x D cable).
Q:- What is the neutral conductor color?
A:- The neutral conductor is always blue.
Q:- Is this cable RoHS compliant?
A:- Yes, the product is RoHS compliant.




Reviews
There are no reviews yet.