SVT-s 0.6/1 kV UV-Steady Power Cable – BDS 16291-85

The SVT-s 0.6/1 kV cable delivers dependable power distribution for outdoor installations and switching applications. Constructed with solid or twisted copper conductors, PVC insulation, and a UV-steady black PVC outer sheath, it offers excellent durability against atmospheric influences and sunlight. Because it meets BDS 16291-85 standards and is RoHS compliant, it provides a safe and reliable solution for exposed environments.

Application
SVT-s cables provide reliable power transfer and distribution for switching installations. Because they are constructed to withstand atmospheric influences and sunlight, installers use them for outdoor installations. Furthermore, they operate efficiently at a rated voltage of Uo/U 0.6/1 kV and a frequency of 50 Hz. Consequently, they deliver consistent performance in exposed environments where UV stability is crucial.

Cable construction
This cable strictly adheres to BDS 16291-85 standards. It features solid or twisted copper wires (class 1 or 2) that comply with BDS 904-84 (IEC 60228). The insulation uses a PVC compound. Finally, a black PVC compound outer sheath protects the entire assembly. Notably, this sheath is UV steady, and the cable is produced without or with joint filling. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to BDS 904-84. The maximum conductor temperature is +70 °C. During a short circuit, it can withstand +160 °C for no more than 5 seconds. It operates at a rated voltage of 0.6/1 kV and undergoes a test voltage of AC – 4 kV 50 Hz and DC – 12 kV. Installers must respect a minimum bending radius of 10 times the cable diameter. The temperature of laying is -5 °C, and the temperature range is -30 °C to +50 °C. Furthermore, it passes the flame test according to BDS IEC 332-1.

Color coding
Clear color coding ensures safe and accurate wiring. Single core cables are black, brown, blue, yellow/green, or other colors upon request. Double core cables feature blue and black. Multi-core configurations include specific color sequences. For instance, 3-core uses brown, black, and grey, or yellow/green, blue, and brown. 4-core uses blue, brown, black, and grey, or yellow/green, brown, black, and grey. 5-core uses blue, brown, black, grey, and black, or yellow/green, blue, brown, black, and grey. Multiple core uses black with number marks on cores or black with number marks on cores and a yellow/green core in the outer cover.

Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data SVT-s 0.6/1 kV

Number of wires and nominal cross-section Shape Outer diameter approx. Cu weight Cable weight approx.
N x mm² mm kg/km kg/km
1 x 1,5 re 7,2 14 69
1 x 2,5 re 7,6 23 82
1 x 4,0 re 8,0 37 102
1 x 6,0 re 8,7 55 128
1 x 10 re 9,3 93 178
1 x 16 re 10,8 148 253
1 x 25 rm 11,9 229 350
1 x 35 rm 13,0 322 458
1 x 50 rm 15,0 456 608
1 x 70 rm 16,7 648 810
1 x 95 rm 18,4 885 1100
1 x 120 rm 19,9 1120 1325
1 x 150 rm 21,9 1378 1610
1 x 185 rm 24,1 1703 2010
1 x 240 rm 27,2 2208 2565
1 x 300 rm 30,3 2765 3200
1 x 400 rm 33,7 3690 4010
1 x 500 rm 37,9 4600 5180
2 x 1,5 re 9,3 28 100
2 x 2,5 re 10,0 46 130
2 x 4,0 re 10,6 75 150
2 x 6,0 re 12,1 112 210
2 x 10 re 15,2 182 370
2 x 16 rm 17,8 303 500
2 x 25 rm 23,8 485 1057
2 x 35 rm 25,9 652 1237
2 x 50 rm 27,9 928 1408
3 x 1,5 re 10,2 42 122
3 x 2,5 re 11,0 69 154
3 x 4,0 re 12,8 110 210
3 x 6,0 re 14,0 165 260
3 x 10 re 16,0 275 480
3 x 16 rm 18,9 450 682
3 x 25 rm 22,8 700 1070
3 x 35 rm 25,9 1000 1336
3 x 50 rm 28,9 1390 1895
3 x 70 sm 28,9 1850 2400
3 x 95 sm 33,1 2650 3255
3 x 120 sm 35,9 3350 4010
3 x 150 sm 39,3 4185 4830
3 x 185 sm 43,4 5160 6055
3 x 240 sm 48,9 6720 7810
3 x 1,5 + 1,5 re/re 11,2 56 140
3 x 2,5 + 1,5 re/re 13,2 76 205
3 x 4,0 + 4,0 re/re 14,4 202 380
3 x 10 + 6,0 re/re 16,7 330 545
3 x 16 + 10 rm/re 20,6 580 845
3 x 25 + 16 rm/re 24,5 580 1245
3 x 35 + 16 rm/rm 27,3 1130 1590
3 x 50 + 25 sm/rm 30,8 1630 2175
3 x 70 + 35 sm/rm 34,9 2280 2785
3 x 95 + 50 sm/rm 36,8 3120 3680
3 x 120 + 70 sm/rm 40,1 4010 4780
3 x 150 + 70 sm/rm 44,3 4830 5620

Construction data SVT-s 0.6/1 kV

Number of wires and nominal cross-section Shape Outer diameter approx. Cu weight Cable weight approx.
N x mm² mm kg/km kg/km
3 x 185 + 95 sm/rm 48,3 6070 7480
3 x 240 + 120 sm/rm 55,4 7840 9150
4 x 1,0 re 10,4 37 140
4 x 1,5 re 11,0 55 165
4 x 2,5 re 11,9 92 216
4 x 4,0 re 13,9 146 298
4 x 6,0 re 16,8 218 375
4 x 10 re 18,3 363 583
4 x 16 rm 20,3 595 925
4 x 25 rm 25,0 970 1285
4 x 35 rm 28,0 1305 1778
4 x 50 sm 33,0 2301 3101
4 x 70 sm 37,3 2601 4100
4 x 95 sm 41,3 4540 5250
4 x 120 sm 45,2 5575 6350
4 x 150 sm 49,5 5855 7590
4 x 185 sm 54,4 6790 9780
5 x 1,0 re 11,2 45 160
5 x 1,5 re 11,8 69 195
5 x 2,5 re 13,8 116 275
5 x 4,0 re 15,5 182 380
5 x 6,0 re 16,8 275 500
5 x 10 re 23,2 745 1150
5 x 16 rm 23,2 745 1150
5 x 25 rm 27,9 1165 1700
5 x 35 rm 30,9 1690 2110
5 x 50 sm 36,9 2330 3130
5 x 70 sm 42,0 3230 4230
7 x 1,5 re 12,0 96 230
10 x 1,5 re 14,7 140 315
12 x 1,5 re 14,7 140 315
14 x 1,5 re 16,1 195 410
16 x 1,5 re 17,1 220 470
19 x 1,5 re 17,1 220 550
21 x 1,5 re 18,3 270 600
24 x 1,5 re 22,6 410 840
30 x 1,5 re 26,5 506 1110
37 x 1,5 re 26,5 506 1110
8 x 2,5 re 14,1 182 365
10 x 2,5 re 18,2 225 445
12 x 2,5 re 18,2 279 485
14 x 2,5 re 18,2 330 550
16 x 2,5 re 18,2 330 570
19 x 2,5 re 24,5 546 695
21 x 2,5 re 24,5 546 695
24 x 2,5 re 25,3 552 1210
30 x 2,5 re 25,3 685 1210
37 x 2,5 re 28,6 845 1480
7 x 4,0 re 19,3 255 470
7 x 6,0 re 20,0 384 630
7 x 10 re 17,3 384 640

Note: Cable may be produced without joint filling.

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the SVT-s cable?
A:- It is used for transferring and distributing electrical power in switching installations and outdoor installations, specifically designed to withstand atmospheric influences and sunlight.

Q:- What are the key features of this cable’s outer sheath?
A:- The black PVC outer sheath is UV steady, providing excellent protection against sunlight and weather conditions for outdoor applications.

Q:- What standards does the cable construction follow?
A:- The construction adheres to BDS 16291-85 standards, and the conductor complies with BDS 904-84 (IEC 60228).

Q:- What type of conductor and insulation does it use?
A:- It uses solid or twisted copper wires (class 1 or 2) with PVC insulation.

Q:- What is the temperature range for this cable?
A:- The temperature of laying is -5°C, and the operating temperature range is -30°C to +50°C.

Q:- What is the maximum conductor temperature and short-circuit limit?
A:- The maximum conductor temperature is +70°C. During a short circuit, it can withstand +160°C for no more than 5 seconds.

Q:- What is the test voltage for this cable?
A:- The test voltage is AC – 4 kV 50 Hz and DC – 12 kV.

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 10 times the cable diameter (10 x D cable).

Q:- Is this cable flame retardant?
A:- Yes, it passes the flame test according to BDS IEC 332-1.

Q:- Is this cable RoHS compliant?
A:- Yes, the product is RoHS compliant.

Reviews

There are no reviews yet.

Be the first to review “SVT-s 0.6/1 kV UV-Steady Power Cable – BDS 16291-85”