SVT 0.6/1 kV Power Cable – BDS 16291-85

The SVT 0.6/1 kV cable delivers dependable power distribution for industrial and infrastructure applications. Constructed with solid or twisted copper conductors, PVC insulation, and a grey or black PVC outer sheath, it offers excellent durability for outdoor and interior installations. Because it meets BDS 16291-85 standards and is RoHS compliant, it provides a safe and reliable solution for switching installations, canals, tunnels, and shafts.

Application
SVT cables provide reliable power transfer and distribution for switching installations. Because they feature a robust PVC construction, installers use them for outdoor installations and interior installations in rooms. Furthermore, they perform reliably in canals, tunnels, shafts, and pits. They operate at a rated voltage of Uo/U 0.6/1 kV and a frequency of 50 Hz. Consequently, they deliver consistent performance in demanding infrastructure environments.

Cable construction
This cable strictly adheres to BDS 16291-85 standards. It features solid or twisted copper wires (class 1 or 2) that comply with BDS 904-84 (IEC 60228). The insulation uses a PVC compound. Finally, a grey or black PVC compound outer sheath protects the entire assembly. Notably, the cable is produced with or without a joint filling. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to BDS 904-84. The maximum conductor temperature is +70 °C. During a short circuit, it can withstand +160 °C for no more than 5 seconds. It operates at a rated voltage of 0.6/1 kV and undergoes a test voltage of AC – 4 kV 50 Hz and DC – 12 kV. Installers must respect a minimum bending radius of 10 times the cable diameter. The temperature of laying is -5 °C, and the temperature range is -30 °C to +50 °C. Furthermore, it passes the flame test according to BDS IEC 332-1.

Color coding
Clear color coding ensures safe and accurate wiring. Single core cables are black, brown, blue, yellow/green, or other colors upon request. Double core cables feature light blue and brown, or yellow-green and black. Multi-core configurations include specific color sequences. For instance, 3-core uses brown, black, and grey, or yellow/green, blue, and brown. 4-core uses blue, brown, black, and grey, or yellow/green, brown, black, and grey. 5-core uses blue, brown, black, grey, and black, or yellow/green, blue, brown, black, and grey. Multiple core uses black with number marks on cores or black with number marks on cores and a yellow/green core in the outer cover.

Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data SVT 0.6/1 kV

Number of wires and nominal cross-section Shape Outer diameter approx. Cu weight Cable weight approx.
N x mm² mm kg/km kg/km
1 x 1,5 re 7,2 14 69
1 x 2,5 re 7,6 23 81
1 x 4,0 re 8,0 37 102
1 x 6,0 re 8,5 55 125
1 x 10 re 9,3 93 178
1 x 16 re 10,8 148 253
1 x 25 re 11,9 225 350
1 x 35 rm 13,0 325 462
1 x 50 rm 15,0 456 608
1 x 70 rm 16,7 648 810
1 x 95 rm 18,4 885 1100
1 x 120 rm 21,4 1120 1325
1 x 150 rm 22,8 1379 1610
1 x 185 rm 24,3 1703 2020
1 x 240 rm 27,2 2208 2565
1 x 300 rm 30,0 2760 3130
1 x 400 rm 33,8 3680 4010
1 x 500 rm 37,9 4800 5180
2 x 1,5 re 8,9 28 94
2 x 2,5 re 10,0 46 120
2 x 4,0 re 10,6 75 150
2 x 6,0 re 11,5 112 190
2 x 10 re 13,2 188 270
2 x 16 rm 15,2 298 370
2 x 25 rm 17,8 485 580
2 x 35 rm 19,9 673 800
2 x 50 rm 23,8 652 1057
2 x 70 rm 27,0 928 1406
3 x 1,5 re 10,2 42 122
3 x 2,5 re 11,0 69 154
3 x 4,0 re 12,3 112 210
3 x 6,0 re 14,0 165 266
3 x 10 re 16,0 275 480
3 x 16 rm 18,9 450 730
3 x 25 rm 22,5 728 1056
3 x 35 rm 25,3 980 1298
3 x 50 rm 28,9 1390 1895
3 x 70 sm 32,7 1968 2400
3 x 95 sm 33,1 2650 3255
3 x 120 sm 35,9 3350 4010
3 x 150 sm 39,5 4245 4895
3 x 185 sm 43,4 5160 6035
3 x 240 sm 48,9 6720 7818
3 x 1,5 + 1,5 re/re 12,4 56 155
3 x 4,0 + 2,5 re/re 13,4 132 293
3 x 6,0 + 4,0 re/re 14,4 202 380
3 x 10 + 6,0 re/re 16,7 330 545
3 x 16 + 10 rm/re 20,6 580 845
3 x 25 + 16 rm/re 24,5 580 1245
3 x 35 + 16 rm/rm 27,3 1130 1590
3 x 50 + 25 sm/rm 30,3 1800 2075
3 x 70 + 35 sm/rm 31,8 2280 2785
3 x 95 + 50 sm/rm 36,8 3120 3680
3 x 120 + 70 sm/rm 41,9 4060 5090
3 x 150 + 70 sm/rm 44,3 4850 5620
3 x 185 + 95 sm/rm 49,3 6070 7090
3 x 240 + 120 sm/rm 55,4 7840 9150
4 x 1,5 re 11,0 55 165
4 x 2,5 re 11,9 92 215
4 x 4,0 re 13,6 146 317
4 x 6,0 re 15,1 216 375
4 x 10 re 18,4 363 583
4 x 16 rm 20,5 595 951
4 x 25 rm 25,0 970 1385
4 x 35 rm 28,0 1325 1737
4 x 50 sm 33,0 2307 3101
4 x 70 sm 37,5 2601 3138
4 x 95 sm 41,2 4460 5210
4 x 120 sm 45,2 5575 6385
4 x 150 sm 50,6 5855 7620
4 x 185 sm 55,6 8042 9800
5 x 1,5 re 11,2 45 160
5 x 2,5 re 14,6 89 245
5 x 4,0 re 15,5 182 380
5 x 6,0 re 16,8 275 500
5 x 10 re 20,0 450 730
5 x 16 rm 23,2 745 1150
5 x 25 rm 27,9 1165 1700
5 x 35 rm 31,5 1683 2100
5 x 50 sm 36,9 2330 3130
5 x 70 sm 42,0 3260 4230
5 x 95 sm 48,7 4430 5640
5 x 120 sm 50,6 5750 6350
8 x 1,5 re 13,1 110 265
10 x 1,5 re 14,7 140 315
12 x 1,5 re 15,2 165 375
14 x 1,5 re 16,1 195 415
16 x 1,5 re 17,1 220 470
19 x 1,5 re 17,3 270 505
21 x 1,5 re 19,0 284 595
24 x 1,5 re 21,2 330 670
30 x 1,5 re 22,6 410 850
37 x 1,5 re 23,1 506 1050
6 x 2,5 re 14,0 145 365
8 x 2,5 re 17,0 186 445
10 x 2,5 re 18,5 225 545
12 x 2,5 re 18,8 279 570
14 x 2,5 re 20,1 321 650
16 x 2,5 re 20,8 355 670
19 x 2,5 re 22,3 441 785
24 x 2,5 re 25,3 552 865
30 x 2,5 re 25,3 685 1210
37 x 2,5 re 28,6 845 1480
7 x 4,0 re 19,4 298 560
7 x 6,0 re 20,0 384 645

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the SVT cable?
A:- It is used for transferring and distributing electrical power in switching installations, as well as for outdoor and interior installation in rooms, canals, tunnels, shafts, and pits.

Q:- What standards does the cable construction follow?
A:- The construction adheres to BDS 16291-85 standards, and the conductor complies with BDS 904-84 (IEC 60228).

Q:- What type of conductor and insulation does it use?
A:- It uses solid or twisted copper wires (class 1 or 2) with PVC insulation and a PVC sheath.

Q:- What is the temperature range for this cable?
A:- The temperature of laying is -5°C, and the operating temperature range is -30°C to +50°C.

Q:- What is the maximum conductor temperature and short-circuit limit?
A:- The maximum conductor temperature is +70°C. During a short circuit, it can withstand +160°C for no more than 5 seconds.

Q:- What is the test voltage for this cable?
A:- The test voltage is AC – 4 kV 50 Hz and DC – 12 kV.

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 10 times the cable diameter (10 x D cable).

Q:- Is this cable flame retardant?
A:- Yes, it passes the flame test according to BDS IEC 332-1.

Q:- What are the color coding options for the 3-core variant?
A:- The 3-core variant uses brown, black, and grey, or yellow/green, blue, and brown.

Q:- Is this cable RoHS compliant?
A:- Yes, the product is RoHS compliant.

Reviews

There are no reviews yet.

Be the first to review “SVT 0.6/1 kV Power Cable – BDS 16291-85”

Your email address will not be published. Required fields are marked *