SVT 0.6/1 kV Power Cable – BDS 16291-85
The SVT 0.6/1 kV cable delivers dependable power distribution for industrial and infrastructure applications. Constructed with solid or twisted copper conductors, PVC insulation, and a grey or black PVC outer sheath, it offers excellent durability for outdoor and interior installations. Because it meets BDS 16291-85 standards and is RoHS compliant, it provides a safe and reliable solution for switching installations, canals, tunnels, and shafts.
Application
SVT cables provide reliable power transfer and distribution for switching installations. Because they feature a robust PVC construction, installers use them for outdoor installations and interior installations in rooms. Furthermore, they perform reliably in canals, tunnels, shafts, and pits. They operate at a rated voltage of Uo/U 0.6/1 kV and a frequency of 50 Hz. Consequently, they deliver consistent performance in demanding infrastructure environments.
Cable construction
This cable strictly adheres to BDS 16291-85 standards. It features solid or twisted copper wires (class 1 or 2) that comply with BDS 904-84 (IEC 60228). The insulation uses a PVC compound. Finally, a grey or black PVC compound outer sheath protects the entire assembly. Notably, the cable is produced with or without a joint filling. Furthermore, this product is RoHS compliant.
Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to BDS 904-84. The maximum conductor temperature is +70 °C. During a short circuit, it can withstand +160 °C for no more than 5 seconds. It operates at a rated voltage of 0.6/1 kV and undergoes a test voltage of AC – 4 kV 50 Hz and DC – 12 kV. Installers must respect a minimum bending radius of 10 times the cable diameter. The temperature of laying is -5 °C, and the temperature range is -30 °C to +50 °C. Furthermore, it passes the flame test according to BDS IEC 332-1.
Color coding
Clear color coding ensures safe and accurate wiring. Single core cables are black, brown, blue, yellow/green, or other colors upon request. Double core cables feature light blue and brown, or yellow-green and black. Multi-core configurations include specific color sequences. For instance, 3-core uses brown, black, and grey, or yellow/green, blue, and brown. 4-core uses blue, brown, black, and grey, or yellow/green, brown, black, and grey. 5-core uses blue, brown, black, grey, and black, or yellow/green, blue, brown, black, and grey. Multiple core uses black with number marks on cores or black with number marks on cores and a yellow/green core in the outer cover.
Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.
Construction data SVT 0.6/1 kV
| Number of wires and nominal cross-section | Shape | Outer diameter approx. | Cu weight | Cable weight approx. |
|---|---|---|---|---|
| N x mm² | mm | kg/km | kg/km | |
| 1 x 1,5 | re | 7,2 | 14 | 69 |
| 1 x 2,5 | re | 7,6 | 23 | 81 |
| 1 x 4,0 | re | 8,0 | 37 | 102 |
| 1 x 6,0 | re | 8,5 | 55 | 125 |
| 1 x 10 | re | 9,3 | 93 | 178 |
| 1 x 16 | re | 10,8 | 148 | 253 |
| 1 x 25 | re | 11,9 | 225 | 350 |
| 1 x 35 | rm | 13,0 | 325 | 462 |
| 1 x 50 | rm | 15,0 | 456 | 608 |
| 1 x 70 | rm | 16,7 | 648 | 810 |
| 1 x 95 | rm | 18,4 | 885 | 1100 |
| 1 x 120 | rm | 21,4 | 1120 | 1325 |
| 1 x 150 | rm | 22,8 | 1379 | 1610 |
| 1 x 185 | rm | 24,3 | 1703 | 2020 |
| 1 x 240 | rm | 27,2 | 2208 | 2565 |
| 1 x 300 | rm | 30,0 | 2760 | 3130 |
| 1 x 400 | rm | 33,8 | 3680 | 4010 |
| 1 x 500 | rm | 37,9 | 4800 | 5180 |
| 2 x 1,5 | re | 8,9 | 28 | 94 |
| 2 x 2,5 | re | 10,0 | 46 | 120 |
| 2 x 4,0 | re | 10,6 | 75 | 150 |
| 2 x 6,0 | re | 11,5 | 112 | 190 |
| 2 x 10 | re | 13,2 | 188 | 270 |
| 2 x 16 | rm | 15,2 | 298 | 370 |
| 2 x 25 | rm | 17,8 | 485 | 580 |
| 2 x 35 | rm | 19,9 | 673 | 800 |
| 2 x 50 | rm | 23,8 | 652 | 1057 |
| 2 x 70 | rm | 27,0 | 928 | 1406 |
| 3 x 1,5 | re | 10,2 | 42 | 122 |
| 3 x 2,5 | re | 11,0 | 69 | 154 |
| 3 x 4,0 | re | 12,3 | 112 | 210 |
| 3 x 6,0 | re | 14,0 | 165 | 266 |
| 3 x 10 | re | 16,0 | 275 | 480 |
| 3 x 16 | rm | 18,9 | 450 | 730 |
| 3 x 25 | rm | 22,5 | 728 | 1056 |
| 3 x 35 | rm | 25,3 | 980 | 1298 |
| 3 x 50 | rm | 28,9 | 1390 | 1895 |
| 3 x 70 | sm | 32,7 | 1968 | 2400 |
| 3 x 95 | sm | 33,1 | 2650 | 3255 |
| 3 x 120 | sm | 35,9 | 3350 | 4010 |
| 3 x 150 | sm | 39,5 | 4245 | 4895 |
| 3 x 185 | sm | 43,4 | 5160 | 6035 |
| 3 x 240 | sm | 48,9 | 6720 | 7818 |
| 3 x 1,5 + 1,5 | re/re | 12,4 | 56 | 155 |
| 3 x 4,0 + 2,5 | re/re | 13,4 | 132 | 293 |
| 3 x 6,0 + 4,0 | re/re | 14,4 | 202 | 380 |
| 3 x 10 + 6,0 | re/re | 16,7 | 330 | 545 |
| 3 x 16 + 10 | rm/re | 20,6 | 580 | 845 |
| 3 x 25 + 16 | rm/re | 24,5 | 580 | 1245 |
| 3 x 35 + 16 | rm/rm | 27,3 | 1130 | 1590 |
| 3 x 50 + 25 | sm/rm | 30,3 | 1800 | 2075 |
| 3 x 70 + 35 | sm/rm | 31,8 | 2280 | 2785 |
| 3 x 95 + 50 | sm/rm | 36,8 | 3120 | 3680 |
| 3 x 120 + 70 | sm/rm | 41,9 | 4060 | 5090 |
| 3 x 150 + 70 | sm/rm | 44,3 | 4850 | 5620 |
| 3 x 185 + 95 | sm/rm | 49,3 | 6070 | 7090 |
| 3 x 240 + 120 | sm/rm | 55,4 | 7840 | 9150 |
| 4 x 1,5 | re | 11,0 | 55 | 165 |
| 4 x 2,5 | re | 11,9 | 92 | 215 |
| 4 x 4,0 | re | 13,6 | 146 | 317 |
| 4 x 6,0 | re | 15,1 | 216 | 375 |
| 4 x 10 | re | 18,4 | 363 | 583 |
| 4 x 16 | rm | 20,5 | 595 | 951 |
| 4 x 25 | rm | 25,0 | 970 | 1385 |
| 4 x 35 | rm | 28,0 | 1325 | 1737 |
| 4 x 50 | sm | 33,0 | 2307 | 3101 |
| 4 x 70 | sm | 37,5 | 2601 | 3138 |
| 4 x 95 | sm | 41,2 | 4460 | 5210 |
| 4 x 120 | sm | 45,2 | 5575 | 6385 |
| 4 x 150 | sm | 50,6 | 5855 | 7620 |
| 4 x 185 | sm | 55,6 | 8042 | 9800 |
| 5 x 1,5 | re | 11,2 | 45 | 160 |
| 5 x 2,5 | re | 14,6 | 89 | 245 |
| 5 x 4,0 | re | 15,5 | 182 | 380 |
| 5 x 6,0 | re | 16,8 | 275 | 500 |
| 5 x 10 | re | 20,0 | 450 | 730 |
| 5 x 16 | rm | 23,2 | 745 | 1150 |
| 5 x 25 | rm | 27,9 | 1165 | 1700 |
| 5 x 35 | rm | 31,5 | 1683 | 2100 |
| 5 x 50 | sm | 36,9 | 2330 | 3130 |
| 5 x 70 | sm | 42,0 | 3260 | 4230 |
| 5 x 95 | sm | 48,7 | 4430 | 5640 |
| 5 x 120 | sm | 50,6 | 5750 | 6350 |
| 8 x 1,5 | re | 13,1 | 110 | 265 |
| 10 x 1,5 | re | 14,7 | 140 | 315 |
| 12 x 1,5 | re | 15,2 | 165 | 375 |
| 14 x 1,5 | re | 16,1 | 195 | 415 |
| 16 x 1,5 | re | 17,1 | 220 | 470 |
| 19 x 1,5 | re | 17,3 | 270 | 505 |
| 21 x 1,5 | re | 19,0 | 284 | 595 |
| 24 x 1,5 | re | 21,2 | 330 | 670 |
| 30 x 1,5 | re | 22,6 | 410 | 850 |
| 37 x 1,5 | re | 23,1 | 506 | 1050 |
| 6 x 2,5 | re | 14,0 | 145 | 365 |
| 8 x 2,5 | re | 17,0 | 186 | 445 |
| 10 x 2,5 | re | 18,5 | 225 | 545 |
| 12 x 2,5 | re | 18,8 | 279 | 570 |
| 14 x 2,5 | re | 20,1 | 321 | 650 |
| 16 x 2,5 | re | 20,8 | 355 | 670 |
| 19 x 2,5 | re | 22,3 | 441 | 785 |
| 24 x 2,5 | re | 25,3 | 552 | 865 |
| 30 x 2,5 | re | 25,3 | 685 | 1210 |
| 37 x 2,5 | re | 28,6 | 845 | 1480 |
| 7 x 4,0 | re | 19,4 | 298 | 560 |
| 7 x 6,0 | re | 20,0 | 384 | 645 |
Factory Overview
Packaging & Shipping
Frequently asked questions and answer ( Q:- A:- )
Q:- What is the primary application of the SVT cable?
A:- It is used for transferring and distributing electrical power in switching installations, as well as for outdoor and interior installation in rooms, canals, tunnels, shafts, and pits.
Q:- What standards does the cable construction follow?
A:- The construction adheres to BDS 16291-85 standards, and the conductor complies with BDS 904-84 (IEC 60228).
Q:- What type of conductor and insulation does it use?
A:- It uses solid or twisted copper wires (class 1 or 2) with PVC insulation and a PVC sheath.
Q:- What is the temperature range for this cable?
A:- The temperature of laying is -5°C, and the operating temperature range is -30°C to +50°C.
Q:- What is the maximum conductor temperature and short-circuit limit?
A:- The maximum conductor temperature is +70°C. During a short circuit, it can withstand +160°C for no more than 5 seconds.
Q:- What is the test voltage for this cable?
A:- The test voltage is AC – 4 kV 50 Hz and DC – 12 kV.
Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 10 times the cable diameter (10 x D cable).
Q:- Is this cable flame retardant?
A:- Yes, it passes the flame test according to BDS IEC 332-1.
Q:- What are the color coding options for the 3-core variant?
A:- The 3-core variant uses brown, black, and grey, or yellow/green, blue, and brown.
Q:- Is this cable RoHS compliant?
A:- Yes, the product is RoHS compliant.




Reviews
There are no reviews yet.