H03VV-F & H03VVH2-F Flexible PVC Cable – VDE 0281-5 / HD 21.5 S3

The H03VV-F and H03VVH2-F cables deliver dependable electrical connections for light small-duty appliances. Constructed with flexible copper conductors, PVC insulation, and a PVC outer sheath, they offer excellent flexibility and durability for desk instruments, lamps, and household appliances. Because they meet VDE 0281-5, HD 21.5 S3, and IEC 60227-5 standards and are CE/RoHS compliant, they provide a safe and reliable solution for domestic electrical connections.

Application
H03VV-F and H03VVH2-F cables provide reliable electrical connections for light small-duty appliances. Because they feature flexible PVC insulation, installers use them for desk instruments, lamps, fairy lamps, and household appliances. Furthermore, they are suitable for connection to radios and similar equipment, provided the instructions of the electrical appliance permit it. However, cables with a cross-section of 0.5 and 0.75 mm² are not suitable for use in industrial electrical equipment, agriculture, or open spaces.

Cable construction
This cable strictly adheres to VDE 0281-5, HD 21.5 S3, and IEC 60227-5 standards. It features copper wires according to VDE 0295 class 5 and IEC 60228 class 5. The insulation uses a PVC compound type TI2 according to VDE 0207 part 4. The sheath uses a PVC compound type TM2 according to VDE 0207 part 5. The standard color is black or white, with different colors available upon request. Furthermore, this product is both RoHS and CE compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to VDE 0295 cl. 5 and IEC 60228 cl. 5. The core temperature is max 70°C in operation. It operates at a rated voltage of Uo/U 300/300 V for three-phase and alternating current systems. The test voltage is AC 50 Hz at 2000 V. The temperature range is mobile -5°C to +70°C and fixed -40°C to +70°C. Testing follows VDE 0472, test class B according to VDE 0472 part 804 and IEC 332-1.

Color coding
Clear color coding ensures safe and accurate wiring. For 2 cores: blue, brown. For 3 cores: yellow/green, blue, brown. For 4 cores: yellow/green, brown, black, grey. For 5 cores: yellow/green, blue, brown, black, grey.

Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data H03VV-F/H03VVH2-F 300/300V

Number of wires and nominal cross section Approx. outer diameter Copper weight Approx. cable weight
mm² mm kg/km kg/km
H03VV-F
2×0.50 5,3 9,6 40
2×0.75 5,6 14,4 48
3×0.50 5,6 14,4 50
3×0.75 6,0 21,5 59
4×0.75 6,7 27,8 78
4×0.75 6,7 27,8 72
H03VVH2-F
2×0.50 3,3×5,3 9,6 29
2×0.75 3,5×6,8 14,2 41

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the H03VV-F / H03VVH2-F cable?
A:- It is used for connecting light small-duty appliances such as desk instruments, lamps, fairy lamps, household appliances, and radios.

Q:- What are the limitations for using this cable?
A:- Cables with cross-sections of 0.5 and 0.75 mm² are not suitable for industrial electrical equipment, agriculture, or open spaces.

Q:- What standards does the cable construction follow?
A:- The construction adheres to VDE 0281-5, HD 21.5 S3, and IEC 60227-5 standards, and the conductor complies with VDE 0295 class 5 and IEC 60228 class 5.

Q:- What type of conductor and insulation does it use?
A:- It uses copper wires with a PVC compound type TI2 insulation.

Q:- What is the temperature range for this cable?
A:- The fixed temperature range is -40°C to +70°C, and the mobile temperature range is -5°C to +70°C.

Q:- What is the rated voltage and test voltage?
A:- The rated voltage is Uo/U 300/300 V, and the test voltage is AC 50 Hz at 2000 V.

Q:- What is the maximum core temperature?
A:- The maximum core temperature in operation is 70°C.

Q:- What are the standard sheath colors?
A:- The standard sheath colors are black or white, with other colors available upon request.

Q:- What are the color coding options available for 3 cores?
A:- The 3-core variant uses yellow/green, blue, and brown.

Q:- Is this cable flame retardant?
A:- Yes, it passes the flame test according to VDE 0472 test class B, VDE 0472 part 804, and IEC 332-1.