FG7OR 0.6/1 kV Flexible Flame Retardant Power Cable – IEC 60502-1

The FG7OR 0.6/1 kV cable delivers dependable power transmission for industrial and domestic applications. Constructed with flexible copper conductors, HEPR rubber insulation, and a flame retardant PVC outer sheath with reduced corrosive gas emission, it offers exceptional flexibility and fire safety. Because it meets IEC 60502-1 standards and is RoHS compliant, it provides a safe and reliable solution for internal, damp, and outdoor installations.

Application
FG7OR cables provide reliable transmission of electricity up to 1000 V in industrial and domestic installations. Because of their robust design, installers use them for internal installation even in damp surroundings. Furthermore, they are appropriate for outdoor applications, provided there is a possibility for direct installation. Consequently, they deliver consistent performance in demanding environments.

Cable construction
This cable strictly adheres to IEC 60502-1 standards. It features copper wires (flexible class 5) that comply with IEC 60228. The insulation uses a rubber compound type HEPR according to IEC 60502-1 based on HEPR rubber. Core identification follows VDE 0293. Additionally, a flame retarding PVC compound forms the inner sheath. Finally, a grey RAL 7035 PVC compound outer sheath with flame retardant and reduced corrosive gas emission protects the entire assembly. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to IEC 60228 class 5. The maximum operating temperature at the conductor is +90 °C. In the event of a short circuit, it can withstand +250 °C. The minimum temperature is 0 °C. It operates at a rated voltage of 0.6/1 kV and undergoes a test voltage of AC 50 Hz 4 kV. Installers must respect a minimum bending radius of 4 times the cable diameter. Testing follows flame test Class C according to IEC 60332-3.

Color coding
Clear color coding ensures safe and accurate wiring. The cable includes conductors with and without a yellow/green earth core. For 1 core, conductors are black or other. For 2 cores, conductors are blue and brown. For 3 cores, conductors are brown, black, and grey; with a yellow/green core, they are yellow/green, blue, and brown. For 4 cores, conductors are blue, brown, black, and grey; with a yellow/green core, they are yellow/green, brown, black, and grey. For 5 cores, conductors are blue, brown, black, and grey; with a yellow/green core, they are yellow/green, blue, brown, black, and grey. For 5 cores and above, conductors use black with number marks on cores, or black with number marks on cores and a yellow/green core in the outer cover.

Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data FG7OR 600/1000 V

Number of conductors and nominal cross section Outer diameter approx. Mass of Cu Mass of cable approx.
N x mm² mm kg/km kg/km
1×1,5 5,8 11,9 47,4
1×2,5 6,4 20,8 62,9
1×4,0 6,7 32,4 76,0
1×6,0 7,6 48,2 101,4
1×10 8,9 85,5 158,6
1×16 9,8 134,9 210,4
1×25 11,7 206,4 300,6
1×35 13,0 292,8 423,5
1×50 15,2 410,5 564,9
1×70 17,5 564,3 773,2
1×95 19,5 774,2 983,2
1×120 21,4 988,8 1268,9
1×150 24,3 1245,5 1589,6
1×185 26,3 1534,1 1923,9
1×240 30,4 1976,3 2410,1
1×300 33,6 2486,8 2986,3
1×400 37,6 3289,6 3875,5
2×1,5 11,5 24,3 173,5
2×2,5 12,3 40,4 212,5
2×4,0 13,4 66,0 265,8
2×6 14,6 97,2 318,9
2×10 17,6 177,9 501,9
2×16 20,6 256,8 686,5
2×25 26,1 423,8 987,3
2×35 28,4 589,8 1278,2
2×50 30,4 838,5 1724,5
3G1,5 12,1 39,6 199,3
3G2,5 14,8 61,1 252,8
3G4 15,7 87,7 306,4
3G6 17,2 137,9 394,9
3G10 22,5 241,0 624,0
3G16 26,4 354,0 833,4
3G25 32,0 587,2 1207,6
3G35 38,0 801,0 1580,0
3G50 37,7 1371,7 2160,0
3G70 37,7 1788 2980
3G95 42,2 2970 3776

Construction data FG7OR 600/1000 V

Number of conductors and nominal cross section Outer diameter approx. Mass of Cu Mass of cable approx.
N x mm² mm kg/km kg/km
3×120 45,7 3022 4650
3×150 50,1 3619 6040
3×185 54,9 4666 6920
3×240 63,4 6044 9205
3×300 72,7 7531 12535
4×1,5 12,7 59,0 255,4
4×2,5 15,0 97,1 360,0
4×4 16,1 115,0 486,0
4×6 18,2 156,0 498,0
4×10 22,1 235,9 586,0
4×16 25,1 337,2 796,0
4×25 30,0 590,0 988,0
4×35 34,5 770,0 1218,0
3×35+35 33,0 166,0 2650,0
3×50+25 35,0 233,0 4000,0
3×70+35 38,3 416,0 4580,0
3×95+50 44,0 664,0 6250,0
3×120+70 48,8 1112,0 6750,0
3×150+95 57,0 1726,0 9015,0
3×240+150 68,4 3211,0 13500,0
5×1,5 13,7 72 320
5×2,5 16,6 121 432
5×4 18,6 187 570
5×6 21,8 268 828
5×10 25,0 450 1000
5×16 25,0 450 1000
7×1,5 15,7 142 376
7×2,5 19,2 208 530
10×1,5 20,2 202 438
12×1,5 18,3 165 450
12×2,5 19,5 242 580
16×1,5 21,0 290 640
19×1,5 22,2 294 665
19×2,5 22,4 380 805
24×1,5 25,0 400 850
24×2,5 26,5 485 1020
26×1,5 26,5 367 825
30×1,5 27,8 525 1080
30×2,5 27,5 607 1200

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the FG7OR cable?
A:- It is used for the transmission of electricity up to 1000 V in industrial and domestic installations, suitable for internal installation in damp surroundings and outdoor applications.

Q:- What standards does the cable construction follow?
A:- The construction adheres to IEC 60502-1 standards, and the conductor complies with IEC 60228 class 5.

Q:- What type of conductor and insulation does it use?
A:- It uses flexible copper wires (class 5) with rubber compound type HEPR insulation.

Q:- What is the maximum operating and short-circuit temperature?
A:- The maximum operating temperature at the conductor is +90°C, and it can withstand a short circuit temperature of +250°C.

Q:- What is the rated voltage and test voltage?
A:- The rated voltage is Uo/U 0.6/1 kV, and the test voltage is AC 50 Hz 4 kV.

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 4 times the cable diameter (4x D cable).

Q:- What is the minimum operating temperature?
A:- The minimum temperature for operation is 0°C.

Q:- What are the flame retardant properties of this cable?
A:- It features a flame retarding PVC inner sheath and a grey RAL 7035 outer sheath with reduced corrosive gas emission, passing the flame test Class C according to IEC 60332-3.

Q:- What is the color coding for the 3-core variant with a yellow/green core?
A:- The 3-core variant with a yellow/green core features yellow/green, blue, and brown conductors.

Q:- Is this cable RoHS compliant?
A:- Yes, the product is RoHS compliant.

Reviews

There are no reviews yet.

Be the first to review “FG7OR 0.6/1 kV Flexible Flame Retardant Power Cable – IEC 60502-1”

Your email address will not be published. Required fields are marked *

RELATED PRODUCTS