Cu/Al XLPE/CWS/PE-TRIPLEX 6.35/11 kV & 19/33 kV Cable – BS 7870-4.10

The Cu/XLPE/CWS/PE-TRIPLEX and Al/XLPE/CWS/PE-TRIPLEX cables deliver dependable power transfer and distribution for medium voltage networks. Constructed with copper or aluminum conductors, XLPE insulation, a copper wire screen, and a PE outer sheath, they offer excellent thermal and electrical protection for 6.35/11 kV and 19/33 kV applications. Because they meet BS 7870-4.10 standards and are RoHS compliant, they provide a safe and reliable solution for urban networks, substations, and industrial plants.

Application
These medium voltage single-core cables provide reliable transfer and distribution of electrical power in power supply networks. They operate efficiently with nominal voltages of Uo/U 6.35/11 and 19/33 kV, and a frequency of 50 Hz, in urban and district electrical networks. Furthermore, installers use them for the electrical supply of transformer substations, small and medium industrial plants, electric power stations, and industrial systems. Because of their robust design, they are suitable for use in distribution installations and cable ducts, conduits, and shafts. Additionally, they perform reliably on shelves and grilles, directly underground in ditch, and outdoor under shelters.

Cable construction
This cable strictly adheres to BS 7870-4.10 standards. It features copper and aluminum stranded compacted conductors according to IEC 60228 class 2 and BS 6360. The inner semi-conductive layer, insulation, and outer semi-conductive layer all use XLPE or semi-conductive XLPE compounds. The metal screen consists of Cu wires concentrically laid and one contour of Cu tape with a thickness of 0.1 mm. A layer of plastic tape forms the separating layer. The sheath uses a PE compound according to BS 7870. The factory bundles three single-core cables in TRIPLEX. The color is red for 11kV and black for 33kV. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to IEC60228 class 2 and BS 6360. The operating temperature reaches 90 °C continuous. During an overload, it can withstand 130 °C for 100% per year max. In a short circuit, it withstands 250 °C for a maximum of 5 seconds. It operates at nominal voltages of 6.35/11 and 19/33 kV, while the highest system voltage Uo/U is not more than 6.35/11, 19/33 kV, and 36 kV. Test voltage is AC (+) – 15 min for 25.4 kV and 76 kV. The level of partial discharge at 2Uo is max. 10 pC. The minimum bending radius is 15 times the cable diameter. The temperature of laying is no less than -5 °C. The temperature of explosion is -30 to 50 °C. Testing follows BS 7870-4.10. The force of strain in laying max is Al cores: 30NS core, Cu cores: 50NS core, where N is the number of cores and S is the cross-section of conductors in mm.

Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data Cu/XLPE/CWS/PE-TRIPLEX and Al/XLPE/CWS/PE-TRIPLEX 6.35/11; 19/33 kV

Number of conductors and nominal cross section Thickness of insulation Thickness of sheath Nominal cross section of screen Cable diameter approx. Cu/XLPE/CWS/PE-TRIPLEX Mass of Cu approx. Cu/XLPE/CWS/PE-TRIPLEX Mass of cable approx. Al/XLPE/CWS/PE-TRIPLEX Mass of Al approx. Al/XLPE/CWS/PE-TRIPLEX Mass of cable approx.
N x mm² mm mm mm² mm kg/km kg/km kg/km kg/km
6.35/11 kV
3x(1x120m/35) 3,4 2,1 35 78,1 79,1 7603 9505 – –
3x(1x240m/35) 3,4 2,2 35 83,3 84,3 9181 11277 – –
3x(1x300m/35) 3,4 2,3 35 83,3 84,3 9181 11277 – –
6.35/11 kV
3x(1x70m/35) 3,4 1,7 35 58,0 58,5 – – 570 1024 2812
3x(1x95m/35) 3,4 1,9 35 62,9 65,1 – – 720 1208 3412
3x(1x120m/35) 3,4 1,9 35 65,1 70,2 – – 1215 1024 3925
3x(1x185m/35) 3,4 1,9 35 72,4 73,4 – – 1530 1024 4238
3x(1x240m/35) 3,4 2,0 35 78,2 80,0 – – 1955 1024 4922
3x(1x300m/35) 3,4 2,1 35 83,2 84,2 – – 2400 1024 5610
19/33 kV
3x(1x120m/35) 8,0 2,1 35 39,6 41,1 4329 7200 990 1024 4920
3x(1x150m/35) 8,0 2,2 35 41,2 43 5079 8100 1215 1024 5310
3x(1x185m/35) 8,0 2,2 35 92,7 96,7 6084 9300 1530 1024 5835

Note: Other core configuration and special constructions manufactured upon request.

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the Cu/XLPE/CWS/PE-TRIPLEX and Al/XLPE/CWS/PE-TRIPLEX cables?
A:- They are designed for the transfer and distribution of electrical power in urban and district electrical networks and for the electrical supply of transformer substations, small and medium industrial plants, and power stations.

Q:- What are the nominal voltage levels available for this cable?
A:- The cables are available in two nominal voltage levels: Uo/U 6.35/11 kV and 19/33 kV, operating at a frequency of 50 Hz.

Q:- What standards does the cable construction follow?
A:- The construction adheres to BS 7870-4.10 standards, and the conductor complies with IEC 60228 class 2 and BS 6360.

Q:- What type of conductor and insulation does it use?
A:- It uses Cu or Al stranded compacted conductors with XLPE insulation.

Q:- What is the function of the TRIPLEX factory bundle?
A:- Three single-core cables are factory bundled in TRIPLEX to form a three-phase system, which simplifies installation and ensures phase identification.

Q:- What type of metal screen is used in the cable?
A:- The metal screen consists of Cu wires concentrically laid and one contour of Cu tape with a thickness of 0.1 mm.

Q:- What is the maximum operating and short-circuit temperature?
A:- The maximum operating temperature is 90°C continuous, and it can withstand a short circuit temperature of 250°C for a maximum of 5 seconds.

Q:- What is the maximum partial discharge level?
A:- The level of partial discharge at 2Uo is max. 10 pC.

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 15 times the cable diameter (15x D cable).

Q:- What are the temperature limits for laying and explosion?
A:- The temperature of laying is no less than -5°C, and the temperature of explosion is -30 to 50°C.

 