2XSE(F)2YBY & A2XSE(F)2YBY 6/10 kV to 12/20 kV Armoured Three-Core Cable – IEC 60502-2

The 2XSE(F)2YBY and A2XSE(F)2YBY cables deliver dependable power transfer and distribution for medium voltage networks. Constructed with copper or aluminum conductors, XLPE insulation, steel tape armour, and a PE or PVC outer sheath, they offer excellent thermal and mechanical protection for 6/10 kV and 12/20 kV applications. Because they meet IEC 60502-2 standards and are RoHS compliant, they provide a safe and reliable solution for urban networks, substations, and industrial plants.

Application
These medium voltage three-core cables provide reliable transfer and distribution of electrical power in power supply networks. They operate efficiently with nominal voltages of Uo/U 6/10, 12/20, and 12/20 kV, and a frequency of 50 Hz, in urban and district electrical networks. Furthermore, installers use them for the electrical supply of transformer substations, small and medium industrial plants, electric power stations, and industrial systems. Because of their robust design, they are suitable for use in distribution installations and cable ducts, conduits, and shafts. Additionally, they perform reliably on shelves and grilles, directly underground in ditch, and outdoor under shelters.

Cable construction
This cable strictly adheres to IEC 60502-2 standards. It features copper and aluminum stranded compacted conductors according to IEC 60228 class 2. The inner semi-conductive layer, insulation, and outer semi-conductive layer all use XLPE or semi-conductive XLPE compounds. A layer of semi-conductive water absorbing tapes forms the water resisting element. The metal screen consists of Cu wires concentrically laid and one contour of Cu tape with a thickness of 0.1 mm over each phase. The cable assembly features three insulated and screened phases with longitudinal water-blocking elements twisted in a three-core cable. Filling and inner sheath PE-LDPE forms the inner sheath. The armour consists of two steel tapes galvanized. The sheath uses PE compound type 2Y-PE, or PVC compound type ST2 according to IEC 60502 for the “V” variant. The color is black for type 2Y and red for type V. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to BDS904 (IEC60228) class 2. The operating temperature reaches 90 °C continuous. During an overload, it can withstand 130 °C for 100% per year max. In a short circuit, it withstands 250 °C for a maximum of 5 seconds. It operates at nominal voltages of 6/10 and 12/20 kV, while the highest system voltage Uo/U is not more than 6/10, 12/20, and 24 kV. Test voltage is AC (+) – 5 min for 6/10 kV (15 kV) and 12/20 kV (30 kV), or DC (-) – 15 min. The level of partial discharge at 2Uo is max. 5 pC. The minimum bending radius is 15 times the cable diameter. The minimum temperature of laying is no less than -20 °C. The temperature of explosion is -30 to 50 °C. Testing follows IEC 60502-2 and DIN VDE 0276-620. The force of strain in laying max is Al cores: 30NS core, Cu cores: 50NS core, where N is the number of cores and S is the cross-section of conductors in mm.

Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data 2XSE(F)2YBY, A2XSE(F)2YBY 6/10; 12/20 kV

Number of conductors and nominal cross section Thickness of insulation Thickness of sheath Nominal cross section of screen Cable diameter approx. 2XSE(F)2YBY Mass of Cu approx. 2XSE(F)2YBY Mass of cable approx. A2XSE(F)2YBY Mass of Al approx. A2XSE(F)2YBY Mass of cable approx.
N x mm² mm mm mm² mm kg/km kg/km kg/km kg/km
6/10 kV
3×35 m/16 3,4 2,7 16 53,0 1010 3885 295 2960
3×50 m/16 3,4 2,8 16 55,0 1360 4290 505 3160
3×70 m/16 3,4 2,9 16 58,5 1965 5090 585 3710
3×95 m/16 3,4 2,9 16 62,5 2730 6100 805 4175
3×120 m/16 3,4 3,0 16 65,5 3420 6826 1000 4410
3×150 m/25 3,4 3,1 25 68,5 4245 8330 1255 5340
3×185 m/25 3,4 3,2 25 74,5 5310 9676 1575 6040
3×240 m/25 3,4 3,5 25 80,0 6980 11905 2070 7085
12/20 kV
3×35 m/16 5,5 2,9 16 61,0 1010 4195 295 3720
3×50 m/16 5,5 3,0 16 63,5 1360 5040 405 4085
3×70 m/16 5,5 3,1 16 67,0 1965 5366 585 4885
3×95 m/16 5,5 3,2 16 69,6 2730 6442 805 5100
3×120 m/16 5,5 3,3 16 75,0 3420 7123 1000 5370
3×150 m/25 5,5 3,4 25 78,5 4245 8190 1255 6570
3×185 m/25 5,5 3,5 25 83,0 5310 9784 1575 7070
3×240 m/25 5,5 3,8 25 87,5 6980 13070 2070 8160

(Note: The second table in the image labeled “6/10 kV” and “12/20 kV” shows the data for the “2XSE(F)2YBV / A2XSE(F)2YBV” PVC sheathed variant, which mirrors the data above).

Note: Other core configuration and special constructions manufactured upon request.

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the 2XSE(F)2YBY and A2XSE(F)2YBY cables?
A:- They are designed for the transfer and distribution of electrical power in urban and district electrical networks and for the electrical supply of transformer substations, small and medium industrial plants, and power stations.

Q:- What are the nominal voltage levels available for this cable?
A:- The cables are available in two nominal voltage levels: Uo/U 6/10 kV and 12/20 kV, operating at a frequency of 50 Hz.

Q:- What standards does the cable construction follow?
A:- The construction adheres to IEC 60502-2 standards, and the conductor complies with IEC 60228 class 2.

Q:- What type of conductor and insulation does it use?
A:- It uses Cu and Al stranded compacted conductors with XLPE insulation.

Q:- What type of metal screen and armour are used?
A:- The metal screen consists of Cu wires concentrically laid and one contour of Cu tape over each phase, and the armour consists of two steel tapes galvanized.

Q:- What are the differences between the “BY” and “BV” variants?
A:- The “BY” variant uses a PE compound type 2Y-PE sheath in black, while the “BV” variant uses a PVC compound type ST2 sheath in red.

Q:- What is the maximum operating and short-circuit temperature?
A:- The maximum operating temperature is 90°C continuous, and it can withstand a short circuit temperature of 250°C for a maximum of 5 seconds.

Q:- What is the maximum partial discharge level?
A:- The level of partial discharge at 2Uo is max. 5 pC.

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 15 times the cable diameter (15x D cable).

Q:- What are the temperature limits for laying and explosion?
A:- The minimum temperature of laying is no less than -20°C, and the temperature of explosion is -30 to 50°C.