2XS2Y / N2XS2Y / A2XS2Y / NA2XS2Y-TRIPLEX 6/10 kV to 18/30 kV – IEC 60502-2

The 2XS2Y-TRIPLEX, N2XS2Y-TRIPLEX, A2XS2Y-TRIPLEX, and NA2XS2Y-TRIPLEX cables deliver dependable power transfer and distribution for medium voltage networks. Constructed with copper or aluminum conductors, XLPE insulation, and a PE outer sheath, they offer excellent thermal and electrical performance for 6/10 kV, 12/20 kV, and 18/30 kV applications. Because they meet IEC 60502-2 and DIN VDE 0276-620 standards and are RoHS compliant, they provide a safe and reliable solution for urban networks, substations, and industrial plants.

Application
These medium voltage cables provide reliable transfer and distribution of electrical power in power supply networks. They operate efficiently with nominal voltages of Uo/U 6/10 kV, 12/20 kV, and 18/30 kV, and a frequency of 50 Hz, in urban and district electrical networks. Furthermore, installers use them for the electrical supply of transformer substations, small and medium industrial plants, and power distribution installations. Because of their robust design, they are suitable for fixed assembly in lines with unlimited difference levels, indoor installations, cable ducts, conduits, shafts, and directly underground in ditch and outdoor shelters.

Cable construction
This cable strictly adheres to IEC 60502-2 and DIN VDE 0276-620 standards. It features copper and aluminum stranded compacted conductors according to IEC 60228 class 2 and VDE 0295 class 2. The inner semi-conductive layer, insulation, and outer semi-conductive layer all use XLPE or semi-conductive XLPE compounds. The metal screen consists of copper wires concentrically laid and one contour of Cu tape with a thickness of 0.1 mm. A layer of plastic tape forms the separating layer. The sheath uses PE compound type ST7 according to IEC 60502 or type DMP2 according to VDE 0276. The color is black, and these three single-core cables are factory bundled in TRIPLEX. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to BDS904 (IEC60228) class 2. The operating temperature reaches 90 °C continuous. During an overload, it can withstand 130 °C for 100% per year max. In a short circuit, it withstands 250 °C for a maximum of 5 seconds. It operates at nominal voltages of 6/10, 12/20, and 18/30 kV, while the highest system voltage Uo/U is not more than 6/10, 12/20, and 18/30 kV. Test voltage is AC (+) – 5 min for 6/10 kV (15 kV), 12/20 kV (30 kV), and 18/30 kV (48 kV), or DC (-) – 15 min. The level of partial discharge at 2Uo is max. 5 pC. The minimum bending radius is 15 times the cable diameter. The minimum temperature of laying is no less than -20 °C. The temperature of explosion is -30 to 50 °C. Testing follows IEC 60502-2 and DIN VDE 0276-620. The force of strain in laying max is Al cores: 30NS core, Cu cores: 50NS core, where N is the number of cores and S is the cross-section of conductors in mm.

Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data 2XS2Y-TRIPLEX / N2XS2Y-TRIPLEX, A2XS2Y-TRIPLEX / NA2XS2Y-TRIPLEX

Number of conductors and nominal cross section Thickness of insulation Thickness of sheath Nominal cross section of screen Cable diameter approx. 2XS2Y-TRIPLEX Mass of approx. 2XS2Y-TRIPLEX Mass of sheath approx. A2XS2Y-TRIPLEX Mass of approx. A2XS2Y-TRIPLEX Mass of sheath approx.
N x mm² mm mm mm² mm kg/km kg/km kg/km kg/km
6/10 kV
3x(1×35/16) 3,4 2,5 16 49,6 1479 2574 282 1905
3x(1x50m/16) 3,4 2,5 16 51,6 1812 2985 381 2082
3x(1x70m/16) 3,4 2,5 16 56,2 2379 3675 549 2373
3x(1x95m/16) 3,4 2,5 16 60,8 3019 4374 733 2909
3x(1x120m/16) 3,4 2,5 16 64,8 3765 5213 963 3309
3x(1x150m/25) 3,4 2,5 25 73,6 4781 6285 1182 3345
3x(1x185m/25) 3,4 2,5 25 73,6 5790 7533 1485 4007
3x(1x240m/25) 3,4 2,5 25 78,4 7095 9042 1947 4359
3x(1x300m/25) 3,4 2,5 25 84,2 8583 10799 2467 4793
3x(1x400m/35) 3,4 2,5 35 92,8 11641 13872 3090 5861
3x(1x500m/35) 3,4 2,5 35 94,2 13567 16730 4058 6993
12/20 kV
3x(1x35m/16) 5,5 2,5 16 58,3 1479 3069 282 2400
3x(1x50m/16) 5,5 2,5 16 60,5 1812 3501 381 2601
3x(1x70m/16) 5,5 2,5 16 64,6 2379 3992 549 2755
3x(1x95m/16) 5,5 2,5 16 73,6 3019 5103 733 3620
3x(1x120m/16) 5,5 2,5 16 73,6 3765 5643 963 4173
3x(1x150m/25) 5,5 2,5 25 77,8 4781 7026 1182 4387
3x(1x185m/25) 5,5 2,5 25 84,2 5790 7899 1485 4276
3x(1x240m/25) 5,5 2,5 25 84,2 7095 9999 1947 5799
3x(1x300m/25) 5,5 2,5 25 84,2 8583 11182 2467 5797
3x(1x400m/25) 5,5 2,5 25 84,2 8583 11182 3090 5861
3x(1x500m/25) 5,5 2,5 25 84,2 8583 11182 3090 5861
18/30 kV
3x(1x50m/16) 8,0 2,5 16 71,3 3812 4182 351 3279
3x(1x70m/16) 8,0 2,5 16 76,6 2399 4949 549 3642
3x(1x95m/16) 8,0 2,5 16 77,8 3019 5855 762 4047
3x(1x120m/16) 8,0 2,5 16 84,2 4781 7334 863 4836
3x(1x150m/25) 8,0 2,5 25 84,2 4781 7334 1182 5065
3x(1x185m/25) 8,0 2,5 25 88,6 5790 9860 1485 5550

 

Note: Other core configuration and special constructions manufactured upon request.

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the 2XS2Y-TRIPLEX cable?
A:- It is used for the transfer and distribution of electrical power in urban and district electrical networks, as well as for the electrical supply of transformer substations and small to medium industrial plants.

Q:- What are the nominal voltage levels available for this cable?
A:- The cable is available in three nominal voltage levels: Uo/U 6/10 kV, 12/20 kV, and 18/30 kV, operating at a frequency of 50 Hz.

Q:- What standards does the cable construction follow?
A:- The construction adheres to IEC 60502-2 and DIN VDE 0276-620 standards, and the conductor complies with IEC 60228 class 2 and VDE 0295 class 2.

Q:- What type of conductor and insulation does it use?
A:- It uses Cu and Al stranded compacted conductors with XLPE insulation.

Q:- What type of metal screen is used in the cable?
A:- The metal screen consists of copper wires concentrically laid and one contour of Cu tape with a thickness of 0.1 mm.

Q:- What is the maximum operating and short-circuit temperature?
A:- The maximum operating temperature is 90°C continuous, and it can withstand a short circuit temperature of 250°C for a maximum of 5 seconds.

Q:- What is the maximum partial discharge level?
A:- The level of partial discharge at 2Uo is max. 5 pC.

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 15 times the cable diameter (15x D cable).

Q:- What are the temperature limits for laying and explosion?
A:- The minimum temperature of laying is no less than -20°C, and the temperature of explosion is -30 to 50°C.

Q:- What is the maximum force of strain during laying?
A:- The maximum force of strain is 30NS for Al cores and 50NS for Cu cores, where N is the number of cores and S is the cross-section of conductors in mm.

Reviews

There are no reviews yet.

Be the first to review “2XS2Y / N2XS2Y / A2XS2Y / NA2XS2Y-TRIPLEX 6/10 kV to 18/30 kV – IEC 60502-2”

Your email address will not be published. Required fields are marked *

RELATED PRODUCTS