Cu/XLPE/PVC/SWA/PVC 0.6/1 kV Armoured Power Cable – BS 5467-1997
The Cu/XLPE/PVC/SWA/PVC 0.6/1 kV cable delivers dependable power and control distribution for industrial installations and urban networks. Constructed with copper conductors, XLPE insulation, galvanized steel wire armour, and a black PVC outer sheath, it offers excellent thermal and mechanical protection. Because it meets BS 5467 standards and is RoHS compliant, it provides a safe and reliable solution for cable ducts, tunnels, and underground installations requiring extra protection.
Application
Cu/XLPE/PVC/SWA/PVC cables provide reliable power and control distribution for industrial installations and urban networks. They operate efficiently with a nominal voltage of 0.6/1 kV and a frequency of 50 Hz. Because of their robust design, installers use them for fixed assembly in lines with unlimited difference levels. Furthermore, they perform reliably in cable ducts, tunnels, and conduits. Additionally, they function well on shelves and grilles, directly underground in ditch, and outdoor under shelters. Consequently, they deliver consistent performance in demanding infrastructure environments.
Cable construction
This cable strictly adheres to BS 5467-97 standards. It features copper wires stranded according to BS 6360 (IEC 60228) class 2. The insulation uses XLPE compound type GP 8 specified in BS 7655. Colors include 2-cores: brown, blue; 3-cores: brown, black, grey; 4-cores: brown, black, grey, blue; 5-cores: brown, black, grey, green/yellow, blue; Control: black with numbers or white with black numbers. A polymer compound forms the inner sheath. The armour consists of galvanized steel wires applied helically. Finally, a black PVC compound type 9 sheath (specified in BS 7655) protects the entire assembly. Furthermore, this product is RoHS compliant.
Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to BS 6360 (IEC 60228) class 2. The operating temperature reaches a maximum of 90 °C continuous. During an overload, it can withstand 130 °C for 100% per year max. In a short circuit, it withstands 250 °C for a maximum of 5 seconds. It operates at a nominal voltage of 0.6/1 kV, while the highest system voltage is 1.2 kV. Test voltage AC is applied for 5 minutes at 3.5 kV between cores and between core and screen. Installers must respect a minimum bending radius of 6 times the cable diameter for circular cores, or 8 times for sector cores. The laying temperature should not fall below 0 °C, and the explosion temperature ranges from -30 to 50 °C. The force of strain in laying max is based on the number of cores and nominal cross section of cores in mm.
Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.
Construction data Cu/XLPE/PVC/SWA/PVC 0.6/1 kV
| Number of conductors and nominal cross section | Thickness of insulation | Nominal steel armour wire diameter | Thickness of oversheath | Cable diameter approx. | Mass of Cu approx. | Cable weight approx. |
|---|---|---|---|---|---|---|
| N x mm² | mm | mm | mm | mm | kg/km | kg/km |
| 2×1,5 m | 0,6 | 0,9 | 1,3 | 12,1 | 28 | 272 |
| 2×2,5 m | 0,7 | 0,9 | 1,4 | 12,9 | 46 | 317 |
| 2×4,0 m | 0,7 | 0,9 | 1,4 | 14,1 | 75 | 401 |
| 2×6,0 m | 0,7 | 0,9 | 1,4 | 14,9 | 110 | 481 |
| 2×10 m | 0,7 | 0,9 | 1,5 | 17,0 | 182 | 655 |
| 2×16 m | 0,7 | 0,9 | 1,5 | 18,9 | 295 | 826 |
| 2×25 m | 0,9 | 1,25 | 1,6 | 22,6 | 470 | 1203 |
| 2×35 m | 0,9 | 1,6 | 1,7 | 26,2 | 652 | 1732 |
| 3×1,5 m | 0,6 | 0,9 | 1,3 | 12,8 | 43 | 301 |
| 3×2,5 m | 0,7 | 0,9 | 1,4 | 13,7 | 69 | 357 |
| 3×4,0 m | 0,7 | 0,9 | 1,4 | 15,0 | 110 | 457 |
| 3×6,0 m | 0,7 | 0,9 | 1,4 | 15,8 | 165 | 528 |
| 3×10 m | 0,7 | 1,25 | 1,5 | 18,0 | 275 | 808 |
| 3×16 m | 0,7 | 1,25 | 1,6 | 20,1 | 450 | 1267 |
| 3×25 m | 0,9 | 1,6 | 1,7 | 24,2 | 700 | 1646 |
| 3×35 m | 0,9 | 1,6 | 1,8 | 26,8 | 952 | 2138 |
| 4×1,5 m | 0,6 | 0,9 | 1,3 | 13,3 | 55 | 331 |
| 4×2,5 m | 0,7 | 0,9 | 1,4 | 15,0 | 92 | 426 |
| 4×4,0 m | 0,7 | 1,25 | 1,5 | 17,7 | 148 | 623 |
| 4×6,0 m | 0,7 | 1,25 | 1,5 | 18,4 | 218 | 703 |
| 4×10 m | 0,7 | 1,25 | 1,6 | 21,1 | 363 | 1005 |
| 4×16 m | 0,7 | 1,6 | 1,7 | 23,7 | 565 | 1627 |
| 4×25 m | 0,9 | 1,6 | 1,8 | 28,9 | 925 | 2226 |
| 4×35 m | 0,9 | 1,6 | 1,8 | 33,2 | 1303 | 2819 |
| 4×50 sm | 1,0 | 1,6 | 1,9 | 33,6 | 1843 | 3536 |
| 4×70 sm | 1,1 | 2,0 | 2,1 | 37,7 | 2601 | 4199 |
| 4×95 sm | 1,1 | 2,0 | 2,2 | 43,3 | 3545 | 5688 |
| 4×120 sm | 1,2 | 2,0 | 2,3 | 47,1 | 4467 | 6330 |
| 4×150 sm | 1,4 | 2,5 | 2,5 | 51,4 | 5580 | 8227 |
| 4×185 sm | 1,6 | 2,5 | 2,6 | 56,6 | 6860 | 9943 |
| 4×240 sm | 1,7 | 2,5 | 2,7 | 63,2 | 8860 | 12545 |
| 5×1,5 m | 0,6 | 0,9 | 1,3 | 14,3 | 66 | 387 |
| 5×2,5 m | 0,7 | 0,9 | 1,4 | 15,4 | 114 | 482 |
| 5×4,0 m | 0,7 | 1,25 | 1,5 | 19,0 | 182 | 722 |
| 5×6,0 m | 0,7 | 1,25 | 1,5 | 20,0 | 255 | 822 |
| 5×10 m | 0,7 | 1,25 | 1,6 | 22,8 | 475 | 1160 |
| 5×16 m | 0,7 | 1,6 | 1,7 | 25,8 | 745 | 1752 |
| 5×25 m | 0,9 | 1,6 | 1,8 | 31,3 | 1180 | 2613 |
| 5×35 m | 0,9 | 1,6 | 1,9 | 35,2 | 1630 | 3044 |
| 7×1,5 m | 0,6 | 0,9 | 1,4 | 15,2 | 95 | 434 |
| 7×2,5 m | 0,7 | 1,25 | 1,5 | 18,2 | 165 | 674 |
| 10×1,5 m | 0,6 | 1,25 | 1,5 | 18,5 | 140 | 664 |
| 12×1,5 m | 0,6 | 1,25 | 1,5 | 19,2 | 165 | 711 |
| 19×1,5 m | 0,6 | 1,6 | 1,6 | 22,2 | 270 | 1186 |
| 27×1,5 m | 0,6 | 1,6 | 1,7 | 26,7 | 373 | 1385 |
| 37×1,5 m | 0,6 | 1,6 | 1,8 | 29,0 | 508 | 1859 |
| 7×2,5 m | 0,7 | 1,25 | 1,5 | 18,4 | 165 | 784 |
| 12×2,5 m | 0,7 | 1,6 | 1,7 | 22,6 | 320 | 1250 |
| 19×2,5 m | 0,7 | 1,6 | 1,7 | 26,4 | 505 | 1560 |
| 37×2,5 m | 0,7 | 1,6 | 1,9 | 35,7 | 845 | 2347 |
| 7×4,0 m | 0,7 | 1,6 | 1,6 | 21,1 | 258 | 1178 |
| 7×6,0 m | 0,7 | 1,25 | 1,7 | 22,8 | 380 | 1194 |
| 10×4,0 m | 0,7 | 1,6 | 1,8 | 25,9 | 700 | 2330 |
| 27×4,0 m | 0,7 | 2,0 | 1,9 | 36,4 | 1362 | 3316 |
| 37×4,0 m | 0,7 | 2,0 | 2,0 | 39,2 |
Note: Other core configuration and special constructions manufactured upon request.
Factory Overview
Packaging & Shipping

Frequently asked questions and answer ( Q:- A:- )
Q:- What is the primary application of the Cu/XLPE/PVC/SWA/PVC cable?
A:- It is used for power and control in electrical installations with nominal voltage 0.6/1 kV in industrial installations and urban networks.
Q:- Where can this cable be installed?
A:- It is suitable for fixed assembly in lines with unlimited difference levels, in cable ducts, tunnels and conduits, on shelves and grilles, directly underground in ditch and outdoor under shelters.
Q:- What standards does the cable construction follow?
A:- The construction adheres to BS 5467-97 standards, and the conductor complies with BS 6360 (IEC 60228) class 2.
Q:- What type of conductor and insulation does it use?
A:- It uses Cu wires stranded class 2 for the conductor and XLPE compound type GP 8 for insulation.
Q:- What kind of armour protects this cable?
A:- The cable features an armour made of galvanized steel wires applied helically.
Q:- What is the nominal voltage and highest system voltage?
A:- The nominal voltage Uo/U is 0.6/1 kV, and the highest system voltage is 1.2 kV.
Q:- What are the maximum continuous and short circuit temperatures?
A:- The maximum operating temperature is 90°C continuous, and it can withstand a short circuit temperature of 250°C for a maximum of 5 seconds.
Q:- What is the overload temperature capacity?
A:- It can withstand an overload temperature of 130°C for 100% per year maximum.
Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 6 times the cable diameter for circular cores and 8 times for sector cores.
Q:- What are the temperature limits for laying and explosion?
A:- The laying temperature should be no less than 0°C, and the explosion temperature range is -30 to 50°C.



Reviews