U 1000 AR2V 0.6/1 kV XLPE Aluminum Power Cable – NFC 32-321

The U 1000 AR2V 0.6/1 kV cable delivers dependable power distribution for industrial installations and urban networks. Constructed with aluminum conductors, XLPE insulation, and a black PVC outer sheath, it offers excellent thermal and mechanical protection. Because it meets NFC 32-321 standards and is RoHS compliant, it provides a safe and reliable solution for cable ducts, tunnels, and outdoor installations under shelters.

Application
U 1000 AR2V cables provide reliable power distribution and supply for consumers in industrial installations and urban networks. They operate efficiently with a nominal voltage of 0.6/1 kV and a frequency of 50 Hz. Because of their robust design, installers use them for fixed indoor assembly in cable ducts, tunnels, and conduits. Furthermore, they perform reliably on shelves and grilles, directly underground in ditch, and outdoor under shelters. Consequently, they deliver consistent performance provided the conditions for the determined type of cable are met.

Cable construction
This cable strictly adheres to NFC 32-321 standards. It features aluminum wires that comply with NFC 32-321. The single core conductors use class 2, 2.5 to 35mm²; stranded class 2 round and sector conductors use 35 to 240mm². The insulation uses an XLPE compound for superior thermal resistance. For filling, up to 6 cores use PVC filling, while 7 cores and more use polyester tape. Finally, a black PVC compound sheath protects the entire assembly. Furthermore, this product is RoHS compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to NFC 32-321. The operating temperature reaches a maximum of 90 °C continuous. During an overload, it can withstand 130 °C for 100% per year max. In a short circuit, it withstands 250 °C for a maximum of 5 seconds. It operates at a nominal voltage of 0.6/1 kV, while the highest system voltage is 1.2 kV. The temperature range for laying, installing, explosion, and storage is -5 °C to +60 °C, while the operating range is -25 °C to +70 °C. Installers must respect a minimum bending radius of 10 times the cable diameter.

Color coding
Clear color coding ensures safe and accurate wiring. Single core cables are black or yellow/green. Double core cables feature blue and brown, or yellow-green and black. Multi-core configurations include specific color sequences for easy identification.

Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data U 1000 AR2V 0.6/1 kV

Number of conductors and nominal cross section Shape Outer diameter approx. Al weight Cable weight approx.
N x mm² mm kg/km kg/km
1×10 re 9,2 28 82
1×16 re 10,5 45 106
1×25 re 11,5 68 135
1×35 re 12,5 95 170
1×50 rm 15,0 127 192
1×70 rm 17,0 190 261
1×95 rm 19,0 260 343
1×120 rm 21,0 341 437
1×150 rm 23,0 419 540
1×185 rm 25,5 510 642
1×240 rm 28,5 665 827
2×2,5 re 10,5 14 141
2×4 re 11,5 23 173
2×6 re 14,3 35 250
2×10 re 14,3 56 284
2×16 re 16,0 90 373
2×25 re 20,3 157 522
3×2,5 re 11,0 21 154
3×4 re 12,5 34 188
3×6 re 13,2 51 238
3×10 re 14,9 85 308
3×16 re 17,0 135 405
3×25 re 21,9 210 575
3×35 re 23,1 290 703
3×50 rm 27,0 385 825
3×70 sm 31,3 585 1205
3×95 sm 34,6 809 1430
3×120 sm 39,6 1020 1900
3×150 sm 44,0 1255 1975
3×185 sm 47,0 1579 2510
3×240 sm 55,6 2035 3930
3×2,5 re 11,0 21 154
3×4 re 12,1 36 186
3×6 re 13,2 51 238
3×10 re 14,5 85 308
3×16 re 17,0 135 403
3×25 re 21,9 210 575
3×50+25 rm/rm 29,3 480 915
3×70+35 sm/rm 34,2 680 1254
3×95+50 sm/rm 38,2 910 1620
3×120+70 sm/rm 43,0 1180 2030
3×150+70 sm/rm 46,9 1405 2403
3×185+70 sm/rm 51,8 1750 2931
3×240+95 sm/rm 58,5 2265 3931
4×2,5 re 11,6 28 144
4×4 re 13,2 46 202
4×6 re 14,3 68 288
4×10 re 16,5 112 354
4×16 re 18,7 180 466
4×25 re 22,6 270 655
4×2,5 re 11,6 28 144
4×4 re 12,8 46 186
4×6 re 14,3 68 233
4×10 re 16,5 112 354
4×16 re 18,7 180 466
4×25 re 22,6 270 655
4×35 re 25,3 390 817
4×50 rm 29,7 520 953
4×70 sm 34,7 760 1400
4×95 sm 39,0 990 1830
4×120 sm 44,0 1340 2277
4×150 sm 49,0 1650 2765
4×185 sm 55,0 2100 3620
4×240 sm 62,1 2720 4680
5×2,5 re 12,7 35 195
5×4 re 14,3 58 245
5×6 re 15,9 85 307
5×10 re 18,2 140 410
5×16 re 20,4 225 540
5×25 re 25,3 345 785
7×1,5 re 13,7 49 201
7×2,5 re 16,2 70 268
10×1,5 re 17,0 70 270
10×2,5 re 18,7 84 296
14×1,5 re 18,7 98 323
19×2,5 re 20,9 133 400
24×2,5 re 25,3 210 570
30×2,5 re 27,5 260 662

Note: Other core configuration and special constructions manufactured upon request.

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the U 1000 AR2V cable?
A:- It is used for the distribution and supply of consumers with electrical power with nominal voltage 0.6/1 kV and frequency 50 Hz in industrial installations and urban networks.

Q:- Where can this cable be installed?
A:- It is suitable for fixed indoor assembly in cable ducts, tunnels and conduits, on shelves and grilles, directly underground in ditch and outdoor under shelters.

Q:- What standards does the cable construction follow?
A:- The construction adheres to NFC 32-321 standards, and the conductor complies with NFC 32-321.

Q:- What type of conductor and insulation does it use?
A:- It uses aluminum wires for the conductor and XLPE compound for insulation.

Q:- What is the filling material used for different core counts?
A:- Up to 6 cores use PVC filling, while 7 cores and more use polyester tape.

Q:- What is the nominal voltage and highest system voltage?
A:- The nominal voltage Uo/U is 0.6/1 kV, and the highest system voltage is 1.2 kV.

Q:- What are the maximum continuous and short circuit temperatures?
A:- The maximum operating temperature is 90°C continuous, and it can withstand a short circuit temperature of 250°C for a maximum of 5 seconds.

Q:- What is the overload temperature capacity?
A:- It can withstand an overload temperature of 130°C for 100% per year maximum.

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 10 times the cable diameter (10 x D cable).

Q:- What are the temperature limits for laying and operation?
A:- The temperature range for laying and installing is -5°C to +60°C, while the operating temperature range is -25°C to +70°C.

Reviews

There are no reviews yet.

Be the first to review “U 1000 AR2V 0.6/1 kV XLPE Aluminum Power Cable – NFC 32-321”

Your email address will not be published. Required fields are marked *