E-YY-O & E-YY-J 0.6/1 kV Copper Power Cable – HD 603 Compliant

The E-YY-O and E-YY-J 0.6/1 kV cables deliver reliable power distribution for industrial and secondary network applications. Constructed with solid or multi-strand copper conductors, PVC insulation, and a black PVC outer sheath, they offer exceptional durability. Because they are RoHS and CE compliant, they provide a safe and dependable solution for outdoor, underground, and in-water installations.

Application
E-YY cables provide reliable power distribution in power plants, industrial settings, and switching installations. They also excel in secondary distribution networks. Because of their robust design, installers prefer them for outdoor applications, indoor installations, open air, underground, and even in water. However, you should not use them where mechanical damage is anticipated.

Cable construction
This cable strictly adheres to HD 603 S1 standards. It features solid or multi-strand copper wires (class 1 or 2) that comply with VDE 0295 (IEC 60228). The insulation uses PVC type DIV1 according to HD 603 S1, while core identification follows VDE 0293. Finally, a black PVC type DMV 1 sheath (acc. HD 603 S1) protects the entire assembly. Furthermore, this product is both RoHS and CE compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to VDE 0295 class 1 or 2 (IEC 60228). The maximum conductor temperature reaches +70 °C. During a short circuit, it can withstand +160 °C for no more than 5 seconds. It operates at a rated voltage of 0.6/1 kV and undergoes a test voltage of AC – 4 kV at 50 Hz. Installers must respect a minimum bending radius of 15 times the cable diameter for multi-core cables, or 12 times for single-core cables. Furthermore, it passes the flame test according to VDE 0472 part 804 class B (IEC 332 part 1).

Color coding
Clear color coding ensures safe and accurate wiring. Single core cables are black, or yellow/green. Double core cables feature light blue and brown, or yellow-green and black.

Multi-Core Color Configurations

  • 3-core: brown, black, grey or yellow/green, light blue, brown

  • 4-core: light blue, brown, black, grey or yellow/green, brown, black, grey

  • 5-core: light blue, brown, black, grey, black or yellow/green, light blue, brown, black, grey

Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data E-YY o/j 0.6/1 kV

Number of wires and nominal cross section Shape Outer diameter approx. Cu weight approx. Cable weight approx.
N x mm² mm kg/km kg/km
3 x 1,5 re 11,6 43 201
3 x 2,5 re 12,4 70 247
3 x 4,0 re 13,5 112 350
3 x 6,0 re 14,5 168 435
3 x 10 re 15,2 282 606
3 x 16 rm 11,6 447 828
3 x 25 rm 21,6 698 1179
3 x 70,0 rm 29,2 1968 2380
3 x 95,0 rm 33,2 2732 3233
3 x 120 rm 35,6 3435 3902
3 x 150 rm 39,2 4245 4867
3 x 185,0 rm 42,7 5311 6016
3 x 240,0 rm 48,1 6981 7689
4 x 1,5 rm 12,5 57 248
4 x 2,5 rm 13,5 93 305
5 x 50,0+25 sm 29,1 1605 2091

Construction data E-YY o/j 0.6/1 kV

Number of wires and nominal cross section Shape Outer diameter approx. Cu weight approx. Cable weight approx.
N x mm² mm kg/km kg/km
3 x 70,0+35 sm 33,1 2304 2828
3 x 95,0+50 sm 37,6 3187 3824
3 x 120,0+70 sm 40,5 4096 4779
3 x 150,0+70 sm 44,8 5001 5685
3 x 185,0+95 sm 49,8 6222 7163
4 x 1,5 re 12,5 57 248
4 x 2,5 re 13,5 93 305
4 x 4,0 re 14,6 149 374
4 x 6,0 re 15,7 223 473
4 x 10,0 re 17,7 376 671
4 x 16,0 rm 20,7 595 916
4 x 25,0 rm 23,6 970 1396
4 x 35,0 rm 26,1 1325 1764
4 x 50,0 rm 29,5 1919 2462
5 x 1,5 re 13,7 71 272
5 x 2,5 re 14,7 116 341
5 x 4,0 re 16,0 187 433
5 x 6,0 re 17,5 279 541
5 x 10 re 19,1 470 763
5 x 16 rm 21,8 744 1042

Note: Other core configuration and special constructions manufactured upon request. Cables with same construction may produced according to IEC 60502.

Factory Overview


Packaging & Shipping


Frequently asked questions and answer

Q:- What is the application of E-YY cables?
A:- E-YY is used in power plants industrial and switching installations, in secondary distribution networks and other. These cables are preferably used in outdoor applications, for indoor installations, in the open air, underground and in water where mechanical damage is not anticipated.

Q:- What is the cable construction of the E-YY cable?
A:-

  • Construction: According to HD 603 S1

  • Conductor: Solid or multi-strand Cu wires class 1 or 2 acc. VDE 0295 (IEC 60228)

  • Insulation: PVC type DIV1 acc. HD 603 S1

  • Core identification: According to VDE 0293

  • Sheath: PVC type DMV 1 acc. HD 603 S1

  • Color: Black

Q:- What are the technical data specifications for the E-YY cable?
A:-

  • Conductor resistance at 20 °C: According to VDE 0295 class 1 or 2 (IEC 60228)

  • Max. conductor temperature: +70°C

  • Max. short circuit temperature: +160°C, not more than 5 sec

  • Rated voltage Uo/U: 0.6/1 kV

  • Test voltage: AC – 4 kV 50 Hz

  • Bending radius -single core: 15 cable diameter

  • Bending radius -multi core: 12 cable diameter

  • Flame test: VDE 0472 part 804 class B (IEC 332 part 1)

Q:- What is the color coding for the E-YY cable?
A:-

  • Single core: Black, or yellow/green

  • Double core: Light blue and brown or yellow-green and black