AGKABEL Halogen-Free Safety Cables NHXCH – FE 180, E30 / E90
High-performance circuit integrity cables designed for safety-critical systems. They are halogen-free, flame-retardant, and maintain circuit integrity for 180 minutes (FE 180), meeting E30 or E90 classification. Suitable for indoor installation in dry and wet zones, in/on/under plaster, and for outdoor installation (not for direct burial). Compliant with DIN VDE 0266 and IEC 332-3. Nominal voltage: 0.6/1 kV. Available from 1 to 2 cores, 1.5mm² to 300mm².
AGKABEL GRUPPE LIMITED presents the Halogen-Free Safety Cables NHXCH FE 180 E30 or E90, engineered for maximum safety and reliability in emergency situations. These cables are designed to maintain circuit integrity during a fire (FE 180 for 180 minutes), ensuring that critical systems such as fire alarms, emergency lighting, and smoke extraction fans continue to operate. The halogen-free construction prevents the emission of toxic and corrosive gases, and the flame-retardant properties limit fire spread. They are suitable for indoor installation in dry and wet zones, in, on, and under plaster, as well as for outdoor installation (but not for direct laying below ground).
Technical Data
-
Standard: DIN VDE 0266
-
Nominal voltage: 0.6/1 kV
-
Flame-retardant: IEC 332-3
-
Application: For indoor installation in dry and wet zones, in, on and under plaster. Further use for outdoor installation. But not suitable for direct laying below ground.
-
Classification: E30 (maintains circuit integrity for 30 minutes) or E90 (maintains circuit integrity for 90 minutes).
Technical Specifications Table
E30 Series
| Part N° | N° of cores x cross-sec mm² | Outer diameter ca. mm | Copper weight kg/km | Weight ca. kg/km |
|---|---|---|---|---|
| 11636001 | 1X4 RE | 8,0 | 38,00 | 90,00 |
| 11636002 | 1X6 RE | 9,0 | 58,00 | 100,00 |
| 11636003 | 1X10 RE | 10,0 | 96,00 | 135,00 |
| 11636004 | 1X16 RE | 11,0 | 154,00 | 190,00 |
| 11636005 | 1X25 RM | 12,0 | 240,00 | 290,00 |
| 11636006 | 1X35 RM | 13,0 | 336,00 | 380,00 |
| 11636007 | 1X50 RM | 15,0 | 480,00 | 510,00 |
| 11636008 | 1X70 RM | 17,0 | 672,00 | 695,00 |
| 11636009 | 1X95 RM | 19,0 | 912,00 | 970,00 |
| 11636010 | 1X120 RM | 21,0 | 1.152,00 | 1.230,00 |
| 11636011 | 1X150 RM | 23,0 | 1.440,00 | 1.520,00 |
| 11636012 | 1X185 RM | 26,0 | 1.776,00 | 1.840,00 |
| 11636013 | 1X240 RM | 28,0 | 2.304,00 | 2.470,00 |
| 11636014 | 1X300 RM | 31,0 | 2.880,00 | o. r. |
| 11636015 | 2X1,5 RE | 12,0 | 29,00 | 180,00 |
| 11636016 | 2X2,5 RE | 13,0 | 48,00 | 210,00 |
| 11636017 | 2X4 RE | 14,0 | 77,00 | 260,00 |
| 11636018 | 2X6 RE | 15,0 | 115,00 | 320,00 |
| 11636019 | 2X10 RE | 16,0 | 192,00 | 440,00 |
| 11636020 | 2X16 RM | 19,0 | 307,00 | 620,00 |
| 11636021 | 2X25 RM | 22,0 | 480,00 | 920,00 |
E90 Series
| Part N° | N° of cores x cross-sec mm² | Outer diameter ca. mm | Copper weight kg/km | Weight ca. kg/km |
|---|---|---|---|---|
| 11605023 | 1X4 RE | o. r. | 38,00 | 98,00 |
| 11605028 | 1X6 RE | 10,0 | 58,00 | 120,00 |
| 11605033 | 1X10 RE | 10,0 | 96,00 | 165,00 |
| 11605038 | 1X16 RE | 11,0 | 154,00 | 230,00 |
| 11605043 | 1X25 RM | 13,0 | 240,00 | 340,00 |
| 11605048 | 1X35 RM | 14,0 | 336,00 | 440,00 |
| 11605053 | 1X50 RM | 16,0 | 480,00 | 590,00 |
| 11605058 | 1X70 RM | 18,0 | 672,00 | 800,00 |
| 11605062 | 1X95 RM | 20,0 | 912,00 | 1.100,00 |
| 11605066 | 1X120 RM | 21,0 | 1.152,00 | 1.350,00 |
| 11605069 | 1X150 RM | 24,0 | 1.440,00 | 1.650,00 |
| 11605072 | 1X185 RM | 26,0 | 1.776,00 | 2.000,00 |
| 11605074 | 1X240 RM | 29,0 | 2.304,00 | 2.600,00 |
| 11605076 | 1X300 RM | 32,0 | 2.880,00 | 3.300,00 |
| 11605001 | 2X1,5 RE | 14,0 | 29,00 | 210,00 |
| 11605012 | 2X2,5 RE | 15,0 | 48,00 | 250,00 |
| 11605024 | 2X4 RE | 16,0 | 77,00 | 310,00 |
| 11605029 | 2X6 RE | 17,0 | 115,00 | 380,00 |
| 11605034 | 2X10 RE | 19,0 | 192,00 | 510,00 |
| 11605039 | 2X16 RE | 21,0 | 307,00 | 680,00 |
| 11605044 | 2X25 RM | 25,0 | 480,00 | 1.050,00 |
(Further dimensions available on request. Note: o. r. = on request/variable.)
Factory Overview
Packaging & Shipping


❓ Frequently Asked Questions (FAQ)
1. What are the primary applications for these cables?
They are designed for safety-critical systems such as fire alarms, emergency lighting, and smoke extraction fans. They are suitable for indoor installation in dry and wet zones, in, on, and under plaster, and for outdoor installation (not for direct laying below ground).
2. What is the difference between E30 and E90?
-
E30: The cable maintains circuit integrity for at least 30 minutes in the event of a fire.
-
E90: The cable maintains circuit integrity for at least 90 minutes in the event of a fire.
3. What does “FE 180” mean?
FE 180 indicates that the cable can maintain insulation integrity for 180 minutes under direct flame exposure, which is a key requirement for critical safety circuits.
4. What are the benefits of halogen-free construction?
Halogen-free cables are safer in fire situations as they do not emit toxic or corrosive halogen gases, and they produce minimal smoke, allowing for clearer evacuation routes.
5. What is the voltage rating of these cables?
The nominal voltage is 0.6/1 kV.
6. What standard do these cables comply with?
They comply with DIN VDE 0266 and are flame-retardant according to IEC 332-3.
7. What sizes and core configurations are available?
Available from 1 to 2 cores, with conductor sizes ranging from 1.5mm² to 300mm².


Reviews