AGKABEL Middle Voltage Power Cables – 2XS2Y/N2XS2Y & A2XS2Y/NA2XS2Y (6/10 kV, 12/20 kV, 18/30 kV)
Single-core cables with XLPE insulation designed for the transfer and distribution of electrical power in urban and district networks. Features Cu or Al stranded compacted conductors, semi-conductive layers, a copper wire screen, and a PE sheath. Compliant with IEC 60502-2 / DIN VDE 0276-620 and RoHS. Operating temperature: 90°C continuous. Suitable for distribution installations, power stations, and industrial systems. Available from 35mm² to 500mm².
AGKABEL GRUPPE LIMITED presents the Middle Voltage Power Cables (2XS2Y, N2XS2Y, A2XS2Y, NA2XS2Y), engineered for reliable transfer and distribution of electrical power with nominal voltage Uo/U 6/10, 12/20, 18/30 kV and frequency 50 Hz. Designed for urban and district electrical networks and for the electrical supply of transformer substations, small and medium industrial plants. They are suitable for use in distribution installations, electric power stations, and industrial systems. The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduits and shafts, over shelves and grills, directly underground in ditch and outdoor shelter.
Technical Data
-
Standard: According to IEC 60502-2 and DIN VDE 0276-620
-
Conductor: Cu and Al stranded compacted, according to IEC 60228 class 2 and VDE 0295 class 2
-
Insulation: XLPE compound (with inner and outer semi-conductive layers)
-
Metal screen: Cu wires concentrically laid and one contact of Cu tape with thickness of 0.1mm
-
Sheath: PE compound type ST7 according to IEC 60502 type DMP 2 according to VDE 0276
-
Color: Black
-
Operating temperature: 90°C continuous operation
-
Overload temperature: 130°C / 100h per year max.
-
Short circuit temperature: 250°C / 5 s max.
-
Nominal voltage Uo/U: 6/10; 12/20; 18/30 kV
-
Highest system voltage Uo/U: 6/10; 12/20 kV (12kV; 24kV kV)
-
Test voltage: AC (~) – 5 min / DC (=) – 15 min (6/10: 15kV / 48kV; 12/20: 30kV / 96kV)
-
Level of partial discharge: max. 5 pC at 2*Uo
-
Bending radius, min: 15x D cable
-
Temperature of laying: no less than -20°C
-
Temperature of exploitation: -30 to 50°C
-
Application: Designed for transfer and distribution of electrical power with nominal voltage Uo/U 6/10; 12/20; 18/30 kV and frequency 50 Hz in urban and district electrical networks and for electrical supply of transformer’s substations, small and medium industrial plants. Suitable for use in distribution installations, electric power stations and industrial systems.
Technical Specifications Table (Construction Data)
| Number of conductors and nominal cross section N x mm² | Thickness of insulation (mm) | Thickness of sheath (mm) | Nominal cross-section of screen (mm²) | Cable diameter approx. min (mm) | Cable diameter approx. max (mm) | Mass of Cu approx. (kg/km) | Mass of cable approx. (kg/km) |
|---|---|---|---|---|---|---|---|
| 6/10 kV | |||||||
| 1x35rm/16 | 3,4 | 2,5 | 16 | 23 | 28 | 493 | 858 |
| 1x50rm/16 | 3,4 | 2,5 | 16 | 24 | 29 | 604 | 995 |
| 1x70rm/16 | 3,4 | 2,5 | 16 | 26 | 31 | 793 | 1225 |
| 1x95rm/16 | 3,4 | 2,5 | 16 | 27 | 32 | 1033 | 1506 |
| 1x120rm/16 | 3,4 | 2,5 | 16 | 29 | 34 | 1255 | 1761 |
| 1x150rm/16 | 3,4 | 2,5 | 16* | 30 | 35 | 1507 | 2052 |
| 1x185rm/16 | 3,4 | 2,5 | 16* | 32 | 37 | 1842 | 2427 |
| 1x240rm/16 | 3,4 | 2,5 | 16* | 34 | 39 | 2365 | 3008 |
| 1x150rm/25 | 3,4 | 2,5 | 25 | 30 | 35 | 1596 | 2136 |
| 1x185rm/25 | 3,4 | 2,5 | 25 | 32 | 37 | 1930 | 2511 |
| 1x240rm/25 | 3,4 | 2,5 | 25 | 34 | 39 | 2454 | 3092 |
| 1x300rm/25 | 3,4 | 2,5 | 25 | 36 | 41 | 2980 | 3674 |
| 1x400rm/35 | 3,4 | 2,5 | 35 | 40 | 45 | 3836 | 4598 |
| 1x500rm/35 | 3,4 | 2,5 | 35 | 43 | 48 | 4807 | 5647 |
| 12/20 kV | |||||||
| 1x35rm/16 | 5,5 | 2,5 | 16 | 27 | 32 | 493 | 1023 |
| 1x50rm/16 | 5,5 | 2,5 | 16 | 28 | 33 | 604 | 1167 |
| 1x70rm/16 | 5,5 | 2,5 | 16 | 30 | 35 | 793 | 1409 |
| 1x95rm/16 | 5,5 | 2,5 | 16 | 31 | 36 | 1033 | 1701 |
| 1x120rm/16 | 5,5 | 2,5 | 16 | 33 | 38 | 1255 | 1881 |
| 1x150rm/16 | 5,5 | 2,5 | 16* | 34 | 39 | 1507 | 2266 |
| 1x185rm/16 | 5,5 | 2,5 | 16* | 36 | 41 | 1842 | 2652 |
| 1x240rm/16 | 5,5 | 2,5 | 16* | 39 | 44 | 2365 | 3333 |
| 1x150rm/25 | 5,5 | 2,5 | 25 | 34 | 39 | 1596 | 2350 |
| 1x185rm/25 | 5,5 | 2,5 | 25 | 36 | 41 | 1930 | 2736 |
| 1x240rm/25 | 5,5 | 2,5 | 25 | 39 | 44 | 2454 | 3333 |
| 1x300rm/25 | 5,5 | 2,5 | 25 | 41 | 46 | 2980 | 3930 |
| 1x400rm/35 | 5,5 | 2,5 | 35 | 44 | 49 | 3836 | 4872 |
| 1x500rm/35 | 5,5 | 2,5 | 35 | 47 | 52 | 4807 | 5956 |
| 18/30 kV | |||||||
| 1x50rm/16 | 8 | 2,5 | 16 | 33 | 38 | 604 | 1394 |
| 1x70rm/16 | 8 | 2,5 | 16 | 35 | 40 | 793 | 1648 |
| 1x95rm/16 | 8 | 2,5 | 16 | 36 | 41 | 1033 | 1952 |
| 1x120rm/16 | 8 | 2,5 | 16 | 38 | 43 | 1255 | 2226 |
| 1x150rm/25 | 8 | 2,5 | 25 | 39 | 44 | 1596 | 2622 |
| 1x185rm/25 | 8 | 2,5 | 25 | 41 | 46 | 1930 | 3020 |
| 1x240rm/25 | 8 | 2,5 | 25 | 43 | 48 | 2454 | 3635 |
| 1x300rm/25 | 8 | 2,5 | 25 | 46 | 51 | 2980 | 4262 |
| 1x400rm/35 | 8 | 2,5 | 35 | 49 | 54 | 3836 | 5242 |
| 1x500rm/35 | 8 | 2,5 | 35 | 52 | 57 | 4807 | 6352 |
(Note: For Aluminium conductor versions (A2XS2Y/NA2XS2Y), the “Mass of Al approx.” and “Mass of cable approx.” columns follow the same structure. * indicates screen section of 16mm² is nominal. Further dimensions available on request.)
Factory Overview
Packaging & Shipping


❓ Frequently Asked Questions (FAQ)
1. What are the primary applications for these cables?
They are designed for transfer and distribution of electrical power in urban and district electrical networks, as well as for the electrical supply of transformer’s substations, small and medium industrial plants, and distribution installations, power stations, and industrial systems.
2. What are the key benefits of XLPE insulation?
XLPE (Cross-linked Polyethylene) insulation offers superior dielectric strength, higher current-carrying capacity, and excellent resistance to thermal deformation, making these cables highly reliable for high-voltage power distribution.
3. What is the maximum operating temperature?
The continuous operating temperature is 90°C, with a maximum overload temperature of 130°C (100h/year max) and a short-circuit temperature of 250°C (5s max).
4. What do the different part numbers (2XS2Y, NA2XS2Y, etc.) mean?
-
2X: Copper conductor.
-
NA2X: Aluminium conductor.
-
S: Copper wire screen.
-
2Y: PE (Polyethylene) outer sheath.
5. What is the voltage range of these cables?
They are available in 6/10 kV, 12/20 kV, and 18/30 kV ratings.
6. What standards do these cables comply with?
They comply with IEC 60502-2 and DIN VDE 0276-620, and are RoHS compliant.
7. What sizes and core configurations are available?
Available in single-core configurations, with conductor sizes ranging from 35mm² to 500mm².