AGKABEL Power Cables NAYY-O/J – 0.6/1 kV, Aluminium Conductor
Cost-effective energy distribution cables designed for fixed installation in buildings and direct laying in concrete, water, and underground. Features solid or stranded Aluminium conductors and a robust PVC outer sheath. Compliant with DIN VDE 0276 part 603. Temperature range: -5°C to +50°C (Flexing) | -30°C to +70°C (Fixed). Nominal voltage: 0.6/1 kV, Test voltage: 4 kV. Available from 1 to 4 cores, 25mm² to 300mm².
AGKABEL GRUPPE LIMITED presents the Power Cables NAYY-O/J, engineered for reliable and economical energy distribution. Utilizing Aluminium conductors instead of copper, these cables offer a significant weight and cost advantage while maintaining excellent electrical performance. Designed for fixed installation in buildings, they are also suitable for direct laying in concrete, water, and below ground. The robust PVC sheath provides durable mechanical protection for long-term infrastructure projects.
Technical Data
-
Standard: DIN VDE 0276 part 603
-
Temperature range:
-
Flexing: -5°C to +50°C
-
Fixed installation: -30°C to +70°C
-
-
Nominal voltage: 0.6/1 kV
-
Test voltage: 4 kV
-
Application: Energy distribution cable for fixed installation in buildings, for direct laying in concrete, water and below ground.
Technical Specifications Table
| Part N° | N° of cores x cross-sec mm² | Outer diameter ca. mm | Copper weight kg/km | Weight ca. kg/km |
|---|---|---|---|---|
| Single Core (1x) | ||||
| 12005025 | 1X185 RM | 25,0 | 537,00 | 950,00 |
| 12005026 | 1X240 RM | 27,0 | 696,00 | 1.150,00 |
| 12005027 | 1X300 RM | 30,0 | 870,00 | 1.350,00 |
| 12005037 | 1X400 RM | 33,0 | 1.160,00 | 1.690,00 |
| 3-Core & 4-Core | ||||
| 12005001 | 4X25 RE | 25,0 | 290,00 | 950,00 |
| 12005003 | 4X35 RE | 28,0 | 406,00 | 1.150,00 |
| 12005034 | 4X35 SM | 28,0 | 406,00 | 1.150,00 |
| 12005004 | 4X50 SE | 31,0 | 580,00 | 1.500,00 |
| 12005006 | 4X70 SE | 34,0 | 812,00 | 1.750,00 |
| 12005018 | 4X70 SM | 34,0 | 812,00 | 1.750,00 |
| 12005009 | 4X95 SE | 38,0 | 1.102,00 | 2.200,00 |
| 12005020 | 4X95 SM | 38,0 | 1.102,00 | 2.200,00 |
| 12005011 | 4X120 SE | 41,0 | 1.392,00 | 2.700,00 |
| 12005022 | 4X120 SM | 41,0 | 1.392,00 | 2.700,00 |
| 12005012 | 4X150 SE | 45,0 | 1.740,00 | 3.250,00 |
| 12005024 | 4X150 SM | 45,0 | 1.740,00 | 3.250,00 |
| 12005015 | 4X185 SE | 50,0 | 2.146,00 | 4.000,00 |
| 12005017 | 4X240 SE | 56,0 | 2.784,00 | 5.000,00 |
| 12005035 | 4X240 SM | 56,0 | 2.784,00 | 5.000,00 |
| Large 3-Core & 4-Core | ||||
| 12005031 | 3X240 SM | 89,9 | o. r. | o. r. |
| 12005032 | 3X300 SM | 98,3 | o. r. | o. r. |
(Further dimensions available on request. Note: o. r. = on request/variable.)
Factory Overview
Packaging & Shipping
❓ Frequently Asked Questions (FAQ)
1. What are the primary applications for these cables?
They are designed for energy distribution and fixed installation in buildings, and are suitable for direct laying in concrete, water, and below ground.
2. What are the advantages of Aluminium conductors over Copper?
Aluminium conductors offer a significant weight reduction and are generally more cost-effective than copper, making them ideal for large-scale power distribution projects where weight and budget are key factors.
3. What is the temperature range of these cables?
-
Flexing: -5°C to +50°C
-
Fixed installation: -30°C to +70°C
4. What is the voltage rating of these cables?
The nominal voltage is 0.6/1 kV and the test voltage is 4 kV.
5. What standard do these cables comply with?
They comply with DIN VDE 0276 part 603.
6. Can these cables be laid directly in water?
Yes, they are specifically designed for direct laying in water, as well as in concrete and underground.
7. What sizes and core configurations are available?
Available from 1 to 4 cores, with conductor sizes ranging from 25mm² to 300mm² (and up to 400mm² for single core).




Reviews