AGKABEL Power Cables NYCY – 0.6/1 kV, with Concentric Conductor
Heavy-duty energy distribution cables designed with a concentric copper conductor for enhanced safety and EMC performance. Ideal for fixed installation in buildings and direct laying in concrete, water, and underground. Compliant with DIN VDE 0276 part 603. Temperature range: -5°C to +50°C (Flexing) | -30°C to +70°C (Fixed). Nominal voltage: 0.6/1 kV. Available from 2 to 5 cores, 1.5mm² to 16mm², plus multi-core control configurations.
AGKABEL GRUPPE LIMITED presents the Power Cables NYCY, engineered for reliable energy distribution with added safety features. The key feature of this cable is the concentric conductor (typically a copper wire layer surrounding the insulated cores), which serves as a combined neutral and earth (PE/PEN) conductor, and also provides effective screening against electromagnetic interference. Designed for fixed installation in buildings, these cables are also suitable for direct laying in concrete, water, and below ground, making them highly versatile for infrastructure and industrial projects.
Technical Data
-
Standard: DIN VDE 0276 part 603
-
Temperature range:
-
Flexing: -5°C to +50°C
-
Fixed installation: -30°C to +70°C
-
-
Nominal voltage: 0.6/1 kV
-
Application: Energy distribution cable for fixed installation in buildings, for direct laying in concrete, water and below ground.
Technical Specifications Table
| Part N° | N° of cores x cross-sec mm² | Outer diameter ca. mm | Copper weight kg/km | Weight ca. kg/km |
|---|---|---|---|---|
| Standard Power Cores (1.5mm² to 6mm²) | ||||
| 12003001 | 2X1,5 RE/1,5 | 13,0 | 52,00 | 230,00 |
| 12003011 | 2X2,5 RE/2,5 | 14,0 | 80,00 | 300,00 |
| 12003022 | 2X4 RE/4 | 16,0 | 123,00 | 380,00 |
| 12003026 | 2X6 RE/6 | 18,0 | 182,00 | 480,00 |
| 12003002 | 3X1,5 RE/1,5 | 14,0 | 66,00 | 300,00 |
| 12003012 | 3X2,5 RE/2,5 | 14,0 | 104,00 | 350,00 |
| 12003023 | 3X4 RE/4 | 16,0 | 161,00 | 470,00 |
| 12003027 | 3X6 RE/6 | 18,0 | 240,00 | 580,00 |
| 12003036 | 3X10 RE/10 | 20,5 | 408,00 | 680,00 |
| 12003003 | 4X1,5 RE/1,5 | 14,0 | 81,00 | 330,00 |
| 12003013 | 4X2,5 RE/2,5 | 16,0 | 128,00 | 400,00 |
| 12003024 | 4X4 RE/4 | 18,0 | 200,00 | 550,00 |
| 12003028 | 4X6 RE/6 | 19,0 | 297,00 | 650,00 |
| 12003004 | 5X1,5 RE/1,5 | 15,0 | 95,00 | 330,00 |
| 12003014 | 5X2,5 RE/2,5 | 16,0 | 152,00 | 400,00 |
| 12003037 | 5X4 RE/4 | 19,0 | 238,00 | 550,00 |
| 12003038 | 5X6 RE/6 | 20,0 | 355,00 | 700,00 |
| Larger Power Cores (10mm² to 16mm²) | ||||
| 12003029 | 1X10 RE/10 | 11,0 | 216,00 | 315,00 |
| 12003044 | 2X10 RE/10 | 20,0 | 312,00 | 650,00 |
| 12003047 | 4X10 RE/10 | 21,0 | 504,00 | 820,00 |
| 12003030 | 1X16 RE/16 | 12,0 | 336,00 | 435,00 |
| 12003045 | 2X16 RE/16 | 22,0 | 489,00 | 900,00 |
| 12003046 | 3X16 RE/16 | 23,0 | 843,00 | 1.100,00 |
| 12003048 | 4X16 RE/16 | 23,0 | 796,00 | 1.250,00 |
| Special Configurations | ||||
| 12003060 | 12X6 RE/10 | 27,0 | 810,00 | 1.350,00 |
| 12003043 | 10x2x1,5 RE/10 | 33,0 | 403,00 | 1.210,00 |
| 12003061 | 20x2x1,5 RE/10 | 33,1 | 696,00 | 968,00 |
| 12003034 | 20x2x2,5 RE/25 | 39,0 | 1.204,00 | 2.405,00 |
| 12003034 | 50x2x1,5 RE/35 | 54,0 | 1.933,00 | 4.010,00 |
(Further dimensions available on request.)
Factory Overview
Packaging & Shipping


❓ Frequently Asked Questions (FAQ)
1. What are the primary applications for these cables?
They are designed for energy distribution and fixed installation in buildings, and are suitable for direct laying in concrete, water, and below ground.
2. What is the purpose of the concentric conductor?
The concentric conductor (the copper wires surrounding the cores) serves multiple purposes:
-
It acts as a combined neutral and earth (PE/PEN) conductor.
-
It provides effective electromagnetic screening (EMC), protecting the cable from external interference and reducing emissions.
3. What is the temperature range of these cables?
-
Flexing: -5°C to +50°C
-
Fixed installation: -30°C to +70°C
4. What is the voltage rating of these cables?
The nominal voltage is 0.6/1 kV.
5. What standard do these cables comply with?
They comply with DIN VDE 0276 part 603.
6. Can these cables be laid directly in water?
Yes, they are specifically designed for direct laying in water, as well as in concrete and underground.
7. What sizes and core configurations are available?
Available in standard power configurations from 2 to 5 cores (1.5mm² to 16mm²), as well as specialized multi-core control configurations (e.g., 12X6, 10x2x1.5, etc.).


Reviews