AGKABEL Low Voltage Power Cable – A2XY-O; A2XY-J (Al / XLPE / PVC)
Reliable power cables designed for the distribution and supply of consumers in industrial installations and urban networks. Features Aluminium conductors (solid or stranded), XLPE insulation, and a PVC ST2 sheath. Compliant with IEC 60502-1 and RoHS. Nominal voltage: 0.6/1 kV, 50 Hz. Operating temperature: 90°C (130°C overload, 250°C short circuit). Suitable for fixed indoor assembly in cable ducts, conduits, over shelves/grilles, directly underground, and outdoor under shelters. Available from 1x50mm² to 1x500mm² and 4x16mm² to 4x240mm².
Technical Specifications Table (Sample Sizes)
| Number of conductors and nominal cross section N x mm² | Thickness of insulation mm | Thickness of sheath mm | Outer diameter approx. min/max mm | Al weight approx. kg/km | Cable weight approx. kg/km |
|---|---|---|---|---|---|
| Single Core (1x) | |||||
| 1x50rm | 1,0 | 1,8 | 14,6 – 17 | 135 | 245 |
| 1x70rm | 1,1 | 1,8 | 16,5 – 19 | 195 | 318 |
| 1x95rm | 1,1 | 1,8 | 18,5 – 20 | 270 | 391 |
| 1x120rm | 1,2 | 1,8 | 20,0 – 22 | 341 | 469 |
| 1x150rm | 1,4 | 1,8 | 21,9 – 24 | 419 | 565 |
| 1x185rm | 1,6 | 1,8 | 24,1 – 27 | 526 | 681 |
| 1x240rm | 1,7 | 1,8 | 26,6 – 30 | 690 | 846 |
| 1x300rm | 1,8 | 1,8 | 29,4 – 32 | 863 | 1034 |
| 1x400rm | 2,0 | 1,9 | 32,9 – 37 | 1109 | 1304 |
| 1x500rm | 2,2 | 2,0 | 36,7 – 40 | 1461 | 1673 |
| Multicore (4x) | |||||
| 4x16re | 0,7 | 1,8 | 20,5 – 24 | 176 | 546 |
| 4x25re | 0,9 | 1,8 | 24,3 – 31 | 288 | 792 |
| 4x35re | 0,9 | 1,8 | 25,3 – 32 | 398 | 977 |
| 4x50sm | 1,0 | 1,9 | 28,2 – 35 | 539 | 1259 |
| 4x70sm | 1,1 | 2,1 | 32,8 – 40 | 779 | 1445 |
| 4x95sm | 1,1 | 2,1 | 36,6 – 44 | 1079 | 1811 |
| 4x120sm | 1,2 | 2,3 | 39,8 – 48 | 1364 | 2233 |
| 4x150sm | 1,4 | 2,4 | 44,0 – 53 | 1676 | 2696 |
| 4x185sm | 1,6 | 2,6 | 48,4 – 58 | 2105 | 3454 |
| 4x240sm | 1,7 | 2,7 | 62,8 – 64 | 2762 | 4129 |
Factory Overview
Packaging & Shipping


❓ Frequently Asked Questions (FAQ)
1. What are the primary applications for these cables?
They are designed for the distribution and supply of consumers in industrial installations and urban networks. They are suitable for fixed indoor assembly in cable ducts and conduits, over shelves and grilles, directly underground in ditches, and outdoor under shelters.
2. What materials are used in the construction?
The cables feature Aluminium conductors (solid or stranded), XLPE (cross-linked polyethylene) insulation, and a PVC type ST2 sheath.
3. What are the temperature ratings for these cables?
-
Operating temperature: 90°C
-
Overload temperature: 130°C (for 100 hours per year)
-
Short circuit temperature: 250°C (for 5 seconds)
4. What is the voltage rating of these cables?
The nominal voltage is 0.6/1 kV (with a highest system voltage of 1.2 kV) and the AC test voltage is 4.0 kV.
5. What standards do these cables comply with?
They comply with IEC 60502-1 and are RoHS compliant. Conductor resistance is according to IEC 60228.
6. What sizes and core configurations are available?
Available in single-core (1x50mm² to 1x500mm²) and multicore (4x16mm² to 4x240mm²) configurations.
7. How are the cores identified?
Core identification follows the color code according to VDE 0276-603.


Reviews
There are no reviews yet.