NYY-O/J 0.6/1 kV Power Cable – DIN VDE 0276 part 603

The NYY-O/J cable delivers dependable energy distribution for fixed installations in buildings and harsh environments. Constructed with copper conductors, PVC insulation, and a robust PVC outer sheath, it offers excellent durability for direct laying in concrete, water, and below ground. Because it meets DIN VDE 0276 standards, it provides a safe and reliable solution for a wide range of infrastructure projects.

Application
NYY-O/J cables provide reliable energy distribution for fixed installations in buildings. Because they feature a robust PVC construction, installers use them for direct laying in concrete, water, and below ground. Furthermore, their durable design ensures long-term performance in demanding environments. Consequently, they deliver consistent and safe power transmission for a wide range of infrastructure projects.

Cable construction
This cable strictly adheres to DIN VDE 0276 part 603 standards. It features copper conductors (class 1 or 2) according to VDE 0295. The insulation uses a PVC compound. An inner sheath and a durable PVC outer sheath protect the core assembly. The “O” variant typically lacks a green/yellow earth core, while the “J” variant includes it for enhanced safety.

Technical Data
The cable delivers consistent performance under specific conditions. The temperature range is -5 °C to +50 °C for flexing applications and -30 °C to +70 °C for fixed installations. The nominal voltage is 0.6/1 kV.

Constructive Data Tables
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

NYY-O

Part N° N° of cores x cross-sec mm² Outer diameter ca. mm Copper weight kg/km Weight ca. kg/km
12001062 1X1,5 8,0 36,00 130,00
12001190 1X6 8,0 58,00 150,00
12001086 1X10 9,0 96,00 200,00
12001095 1X16 10,0 154,00 270,00
12001105 1X25 12,0 240,00 400,00
12001115 1X35 13,0 336,00 500,00
12001127 1X50 15,0 480,00 650,00
12001137 1X70 16,0 672,00 850,00
12001145 1X95 19,0 912,00 1.150,00
12001155 1X120 20,0 1.152,00 1.400,00
12001158 1X150 22,0 1.440,00 1.700,00
12001163 1X185 25,0 1.776,00 2.100,00
12001169 1X240 27,0 2.304,00 2.650,00
12001175 1X300 30,0 2.880,00 3.300,00
12001181 1X400 34,0 3.840,00 4.150,00
12001182 1X500 37,0 4.800,00 5.200,00
12001184 1X630 44,0 6.048,00 6.450,00
12001001 2X1,5 12,0 29,00 230,00
12001012 2X2,5 13,0 48,00 270,00
12001023 2X4 15,0 77,00 370,00
12001027 2X6 16,0 115,00 450,00
12001087 2X10 17,0 192,00 570,00
12001097 2X16 19,0 307,00 720,00
12001107 2X25 23,0 480,00 1.050,00
12001003 3X1,5 13,0 43,00 250,00
12001042 3X2,5 14,0 72,00 300,00
12001066 3X4 15,0 115,00 400,00
12001069 3X6 17,0 173,00 500,00
12001098 3X16 20,0 461,00 880,00
12001110 3X25 24,0 720,00 1.350,00
12001118 3X35 25,0 1.008,00 1.500,00
12001130 3X50 28,0 1.440,00 2.000,00
12001171 3X240 50,0 6.912,00 8.300,00

NYY-J

Part N° N° of cores x cross-sec mm² Outer diameter ca. mm Copper weight kg/km Weight ca. kg/km
12001009 4X1,5 13,0 58,00 300,00
12001187 4X2,5 14,0 96,00 350,00
12001076 4X4 16,0 154,00 460,00
12001078 4X6 18,0 230,00 600,00
12001090 4X10 20,0 384,00 800,00
12001101 4X16 22,0 614,00 1.100,00
12001126 4X25 26,0 960,00 1.600,00
12001119 4X35 27,0 1.344,00 1.950,00
12001134 4X50 31,0 1.920,00 2.550,00
12001142 4X70 35,0 2.688,00 3.450,00
12001149 4X95 40,0 3.648,00 4.600,00
12001156 4X120 44,0 4.608,00 5.600,00
12001160 4X150 48,0 5.760,00 7.000,00
12001167 4X185 53,0 7.104,00 8.700,00
12001173 4X240 60,0 9.216,00 11.300,00
12001174 5X1,5 14,0 72,00 350,00
12001045 7X1,5 16,0 168,00 420,00
12001017 10X1,5 18,0 144,00 410,00
12001025 12X1,5 19,0 173,00 460,00
12001033 14X1,5 25,0 202,00 520,00

Factory Overview


Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the NYY-O/J cable?
A:- It is used for energy distribution in fixed installations in buildings, as well as for direct laying in concrete, water, and below ground.

Q:- What standards does this cable comply with?
A:- It complies with DIN VDE 0276 part 603 standards, and the conductor complies with VDE 0295.

Q:- What is the difference between the NYY-O and NYY-J variants?
A:- The NYY-O variant typically lacks a green/yellow earth core, while the NYY-J variant includes it.

Q:- What is the nominal voltage?
A:- The nominal voltage is 0.6/1 kV.

Q:- What is the temperature range for this cable?
A:- The temperature range is -5°C to +50°C for flexing and -30°C to +70°C for fixed installation.

Q:- What is the largest cross-section available in the provided tables?
A:- The largest cross-section shown is 1X630 mm² in the NYY-O series.

Q:- What materials are used for insulation and sheathing?
A:- The insulation and sheathing use robust PVC compounds designed for durability and environmental protection.

Q:- Can this cable be laid directly in water?
A:- Yes, it is designed for direct laying in water, as well as concrete and underground.

Q:- Are other dimensions available besides those listed?
A:- Yes, further dimensions are available upon request.

Q:- What type of conductor is used?
A:- It uses copper conductors of class 1 or 2.