FRT-XCAH Flame Retardant Screened Single Core Cable
This flame retardant screened single core cable is engineered for VSD applications and electrical noise reduction in demanding industrial environments. It features a plain annealed copper conductor with XLPE insulation and a copper tape/tinned copper wire braid screen for excellent interference protection. The LSZH outer sheath and aluminium wire armour ensure safety with low smoke and zero halogen emissions. Available in sizes from 70mm² to 1000mm², it is compliant with IEC 60502 and IEC 60332-3 standards.
These flame retardant screened single core cables are specifically designed to drastically reduce interferences from electrical noise, especially in Variable Speed Drive (VSD) applications. Because they are manufactured with plain annealed copper conductors and XLPE insulation, they are exceptionally reliable for demanding industrial power and control circuits. Furthermore, an aluminium wire armour and an LSZH sheath ensure robust mechanical protection and safety, as the cables are designed to be Low Smoke, Zero Halogen, and Flame Retardant. Consequently, they are highly suitable for critical installations where both performance and fire safety are paramount.
The cable structure features a plain annealed copper conductor with Class 2 stranding, insulated with XLPE compound. The screened construction includes copper tapes and a tinned copper wire braid, while the armoured version adds galvanized steel wire and aluminium wire for mechanical protection. Finally, the assembly is protected by a robust LSZH (Low Smoke Zero Halogen) compound sheath in black, with natural color insulation.
Technical Data & Construction Overview:
-
Reference Standard: IEC 60502
-
Test Standard: IEC 60332-3, BS 4066, IEC 60754, BS 6425, IEC 61034, BS 7622-Part-2
-
Voltage Uo/U: 600/1000V
-
Conductor Stranding: Class 2
-
Operating Temperature: (a) Max 90°C for XLPE; (b) Max 110°C for XLEVA
-
Minimum Bending Radius: 12D for 70mm² to 1000mm²
Construction Data (FRT-XCAH)
| Size | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Nominal Conductor Area (mm²) | No. & Dia. of Wires (no./mm) | Radial Thick. of Insulation (mm) | Radial Thick. of Sheath (mm) | Dia. Under Screen (mm) | Dia. Over Bedding (mm) | Armour Wire Dia. (mm) | Cable Overall Dia. (mm) | Approx. Weight (kg/km) | |
| 70 | 19 / 2.14 | 1.1 | 1.8 | 15.2 | 17.6 | 20.1 | 23.9 | 1400 | |
| 95 | 19 / 2.52 | 1.1 | 1.8 | 17.1 | 19.5 | 22.0 | 25.8 | 1700 | |
| 120 | 37 / 2.03 | 1.2 | 1.8 | 19.0 | 20.8 | 24.0 | 27.8 | 2000 | |
| 150 | 37 / 2.25 | 1.4 | 1.8 | 21.0 | 22.8 | 26.0 | 29.8 | 2400 | |
| 185 | 37 / 2.52 | 1.6 | 1.8 | 23.2 | 25.0 | 28.2 | 32.0 | 2800 | |
| 240 | 61 / 2.25 | 1.7 | 1.9 | 26.1 | 27.9 | 31.1 | 35.1 | 3500 | |
| 300 | 61 / 2.52 | 1.8 | 2.0 | 28.9 | 31.5 | 34.9 | 37.9 | 4200 | |
| 400 | 61 / 2.85 | 2.0 | 2.1 | 32.5 | 34.3 | 38.3 | 42.7 | 5400 | |
| 500 | 61 / 3.20 | 2.2 | 2.2 | 36.0 | 37.8 | 41.8 | 46.4 | 6500 | |
| 630 | 127 / 2.52 | 2.4 | 2.5 | 40.4 | 42.2 | 46.2 | 51.0 | 8200 | |
| 800 | 127 / 2.85 | 2.6 | 2.5 | 45.3 | 47.3 | 52.3 | 57.2 | 10400 | |
| 1000 | 127 / 3.20 | 2.8 | 2.7 | 50.4 | 52.2 | 57.2 | 62.4 | 13000 |
This range of screened cables drastically reduce interferences from electrical noise, especially in Variable Speed Drive (VSD) applications and are manufactured with fixed conductors. An additional trait of these cables that are designed to be Low Smoke, Zero Halogen and Flame Retardant. Applicable standards include IEC 60754, IEC 60332-3 and IEC 61034.
Factory Overview
Packaging & Shipping

Frequently asked questions and answer (Q:- A:-)
Q:- What is the primary application of the FRT-XCAH cable?
A:- It is designed to drastically reduce electrical noise interference, especially in Variable Speed Drive (VSD) applications.
Q:- What type of conductor is used?
A:- It features a plain annealed copper conductor with Class 2 stranding.
Q:- What is the reference standard for this cable?
A:- The reference standard is IEC 60502.
Q:- What is the voltage rating?
A:- The voltage rating is Uo/U 600/1000V.
Q:- What is the maximum operating temperature?
A:- The maximum operating temperature is 90°C for XLPE insulation.
Q:- What is the minimum bending radius?
A:- The minimum bending radius is 12D for cable sizes from 70mm² to 1000mm².
Q:- What type of screen is used?
A:- The cable features copper tapes and a tinned copper wire braid screen.
Q:- What material is used for the outer sheath?
A:- The outer sheath is made of LSZH (Low Smoke Zero Halogen) compound in black.
Q:- Does this cable have fire safety certifications?
A:- Yes, it is designed to be Low Smoke, Zero Halogen, and Flame Retardant, compliant with IEC 60332-3 and IEC 61034.
Q:- What is the armour wire diameter for the 70mm² cable?
A:- The armour wire diameter is 20.1mm for the 70mm² cable.



Reviews