PVO 0.6/1 kV PVC Insulated Overhead Line Conductor – FN KI 06 003-06
The PVO 0.6/1 kV cable delivers dependable electrical connections for overhead distribution networks. Constructed with solid or stranded copper conductors and a robust PVC insulation, it offers excellent durability and weather resistance for exposed outdoor environments. Because it meets FN KI 06 003-06 standards, passes the BDS IEC 332-1 flame test, and is CE/RoHS compliant, it provides a safe and reliable solution for connecting homes and installations to open-air networks.
Application
PVO cables provide reliable electrical connections for overhead distribution networks. Because they feature a robust PVC insulation, installers use them for connecting homes and other electrical installations to the open-air electrical distribution network. Furthermore, their single-core construction is optimized for overhead routing. Consequently, they deliver consistent and safe performance in exposed outdoor environments.
Cable construction
This cable strictly adheres to FN KI 06 003-06 standards. It features copper wires according to BDS 904-84 (IEC 60228) class 1, sized from 6 to 10 mm², and class 2, sized from 16 to 70 mm². The insulation uses a PVC compound, type I, according to BDS 5792-84. The standard insulation color is black. Furthermore, this product is both RoHS and CE compliant.
Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to BDS 904-84. The maximum operating temperature of the conductor is 70 °C. It operates at a rated voltage of Uo/U 0.6/1 kV and undergoes a test voltage of AC 50 Hz at 4 kV. The temperature of exploitation is -30 °C to +50 °C. Installers must respect a minimum bending radius of 6 times the cable diameter for fixed installation. Furthermore, it passes the flame test according to FN KI 06 003-06 and BDS IEC 332-1.
Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.
Construction data PVO 0.6/1 kV
| Nominal cross section | Outer diameter approx. | Copper weight | Cable weight approx. |
|---|---|---|---|
| mm² | mm | kg/km | kg/km |
| 6 | 4,8 | 55 | 73 |
| 10 | 6,0 | 91 | 120 |
| 16 | 7,5 | 152 | 191 |
| 25 | 9,0 | 232 | 280 |
| 35 | 10,4 | 315 | 400 |
| 50 | 12,1 | 420 | 530 |
| 70 | 13,9 | 620 | 745 |
Factory Overview
Packaging & Shipping

Frequently asked questions and answer ( Q:- A:- )
Q:- What is the primary application of the PVO cable?
A:- It is used for connecting homes and other electrical installations to the open-air electrical distribution network.
Q:- What standards does the cable construction follow?
A:- The construction adheres to FN KI 06 003-06 standards, and the conductor complies with BDS 904-84 (IEC 60228).
Q:- What type of conductor and insulation does it use?
A:- It uses copper wires (class 1 for 6-10 mm² and class 2 for 16-70 mm²) with a PVC compound, type I, insulation.
Q:- What is the rated voltage for this cable?
A:- The rated voltage is Uo/U 0.6/1 kV.
Q:- What is the maximum operating temperature of the conductor?
A:- The maximum operating temperature is 70°C.
Q:- What is the test voltage for this cable?
A:- The test voltage is AC 50 Hz at 4 kV.
Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 6 times the cable diameter (6x D cable) for fixed installation.
Q:- What is the temperature range for exploitation?
A:- The temperature of exploitation is -30°C to +50°C.
Q:- What is the standard insulation color?
A:- The standard insulation color is black.
Q:- Is this cable RoHS and CE compliant?
A:- Yes, the product is both RoHS and CE compliant.


Reviews