PVV-A3 Flexible PVC Insulated & Sheathed Cable – BDS 4305-90

The PVV-A3 cable delivers dependable electrical connections for fixed installations in lighting, power systems, and machinery. Constructed with flexible copper conductors, PVC insulation, and a robust PVC outer sheath, it offers excellent protection and durability. Because it meets BDS 4305-90 standards, passes the BDS IEC 332-1 flame test, and is CE/RoHS compliant, it provides a safe and reliable solution for internal wiring and equipment connections.

Application
PVV-A3 cables provide reliable electrical connections for fixed installation in various low-voltage systems. Because they feature a durable PVC outer sheath and flexible copper conductors, installers use them extensively in lighting installations, power and distribution systems, machines, and apparatus. Furthermore, their robust construction protects the cores from mechanical damage and environmental factors. Consequently, they deliver consistent performance for internal wiring and equipment connections.

Cable construction
This cable strictly adheres to BDS 4305-90 standards. It features copper wires according to BDS 904-84 (IEC 60228) class 1 or 2. The insulation uses a PVC compound, type I-2, according to BDS 5792-84. The outer sheath uses a PVC compound, type P-1, according to BDS 5792-84. The standard sheath color is black, grey, or white. Furthermore, this product is both RoHS and CE compliant.

Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C according to BDS 904-84 class 1 or 2. The operating temperature of the conductor is max. 70 °C. For the 300/500 V rating, the rated voltage is Uo/U 300/500 V for 0.5 to 1.0 mm², and 450/750 V for 1.5 to 35 mm². The test voltage is AC 50 Hz at 2000 V for 0.5 to 1.0 mm², and 2500 V for 1.5 to 35 mm². The temperature range is -25 °C to +50 °C. Installers must respect a minimum bending radius of 6 times the cable diameter for fixed installation. Furthermore, it passes the flame test according to BDS 4305-90 and BDS IEC 332-1.

Color coding
Clear color coding ensures safe and accurate wiring. For 3 cores with a yellow/green earth core, the colors are yellow/green, blue, and brown. Without a yellow/green earth core, the colors are brown, black, and grey. For 4 cores, the colors are yellow/green, brown, black, and grey, or blue, brown, black, and grey. For 5 cores, the colors are yellow/green, blue, brown, black, and grey, or black, blue, brown, black, and grey. A red reduction core is also available.

Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.

Construction data PVV-A3 300/500V 450/750V

Number of wires and nominal cross section Approx. outer diameter Copper weight Approx. cable weight
mm² mm kg/km kg/km
PVV-A3 300/500V
3×0.50 6,2 14 50
3×0.75 6,6 21 60
3×1.0 6,9 28 72
PVV-A3 450/750V
3×1.5 8,3 41 108
3×2.5 9,5 66 152
3×4.0 10,9 107 218
3×6.0 12,4 165 299
3×10 14,9 264 436
3×16 18,2 425 642
3×25 22,2 660 957
3×35 24,7 927 1275
PVV-A3 300/500V
4×0.50 6,8 18 62
4×0.75 7,2 27 78
4×1.0 7,5 37 90
PVV-A3 450/750V
4×1.5 9 55 133
4×2.5 10,4 89 192
4×4.0 11,9 142 250
4×6.0 13,5 218 361
4×10 16,3 353 583
4×16 20 580 880
4×25 24 880 1225
4×35 27 1266 1680
3×2.5+16 23 809 1150
3×35+25 28,5 1130 1550
PVV-A3 300/500V
5×0.50 7,6 22 74
5×0.75 8,0 34 92

Factory Overview



Packaging & Shipping


Frequently asked questions and answer ( Q:- A:- )

Q:- What is the primary application of the PVV-A3 cable?
A:- It is used for fixed installation in lighting installations, power and distribution systems, machines, and apparatus.

Q:- What standards does the cable construction follow?
A:- The construction adheres to BDS 4305-90 standards, and the conductor complies with BDS 904-84 (IEC 60228) class 1 or 2.

Q:- What type of conductor and insulation does it use?
A:- It uses copper wires with a PVC compound, type I-2, insulation and a PVC compound, type P-1, outer sheath.

Q:- What is the rated voltage for this cable?
A:- The rated voltage is Uo/U 300/500 V for 0.5 to 1.0 mm², and 450/750 V for 1.5 to 35 mm².

Q:- What is the maximum operating temperature of the conductor?
A:- The maximum operating temperature is 70°C.

Q:- What is the test voltage for this cable?
A:- The test voltage is AC 50 Hz at 2000 V for 0.5 to 1.0 mm², and 2500 V for 1.5 to 35 mm².

Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 6 times the cable diameter (6x D cable) for fixed installation.

Q:- What is the temperature range for operation?
A:- The temperature range is -25°C to +50°C.

Q:- What are the standard sheath colors?
A:- The standard sheath colors are black, grey, or white.

Q:- Is this cable RoHS and CE compliant?
A:- Yes, the product is both RoHS and CE compliant.

Reviews

There are no reviews yet.

Be the first to review “PVV-A3 Flexible PVC Insulated & Sheathed Cable – BDS 4305-90”

Your email address will not be published. Required fields are marked *

RELATED PRODUCTS