PE/PJF/PE/SWA/PVC Armoured Control Cable for Induced Voltage up to 15kV – ESI 09-6
The PE/PJF/PE/SWA/PVC …x2x1/0.8 cable delivers dependable control and data transmission for power distribution and transmission systems. Constructed with solid copper conductors, PE insulation, a petroleum jelly filling, steel wire armour, and a black PVC outer sheath, it offers exceptional mechanical and water-blocking protection for induced voltages up to 15kV. Because it meets ESI 09-6 standards and is RoHS compliant, it provides a safe and reliable solution for demanding electrical infrastructures.
Application
PE/PJF/PE/SWA/PVC cables provide reliable control, protection, signaling, telecommunications, and data transmission connections. Because they feature enhanced insulation, a jelly filling, and robust steel wire armour, installers use them for critical applications associated with power distribution and transmission systems. Furthermore, they are specifically designed for environments where induced voltages can reach up to 15kV, ensuring signal integrity and safety in demanding electrical infrastructures.
Cable construction
This cable adheres to ESI 09-6, issue 3 standards. It features a solid copper conductor with a diameter of 0.8 mm. The insulation uses a PE type 03C compound according to BS 6234. Each pair is twisted, with pairs stranded into layers. The cable core filling uses a petroleum-based jelly. A wrapping of several layers of plastic tapes forms the core wrap. A PE compound type 03C forms the inner sheath. A single layer of galvanized steel wires (according to BS 1442) provides the armour. Finally, a PVC compound type TM1 outer sheath (according to BS 7655) protects the entire assembly. The sheath color is black. Furthermore, this product is RoHS compliant.
Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C of max. 73.6 MΩ/km. The mutual capacitance at 1000 Hz is max. 40 nF/km. The insulation resistance at 20°C is min. 5 GΩ.km. The capacitance unbalance at 1000 Hz is max. 500 pF/500m. The test voltage is AC for 1 min between each conductor and earth at 15 kV. The mutual inductance at 5 kHz is max. 0.5 mH/1000m. Attenuation varies by frequency (e.g., 0.51 dB/km at 300 Hz). Characteristic impedance is 550Ω at 10 kHz. The minimum bending radius is 15 x cable diameter.
Cable core construction
The pairs are arranged in layers: 4 pairs (all in first layer), 7 pairs (1 centre, 6 first layer), 19 pairs (1 centre, 6 first layer, 12 second layer), 37 pairs (6 centre, 12 first layer, 18 second layer).
Color coding
Clear color coding ensures safe and accurate wiring. The a-wire colors include black, orange, green, red, blue, and white. The b-wire colors include violet, grey, brown, and yellow, following a specific sequence up to 37 pairs.
Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.
Mechanical data PE/PJF/PE/SWA/PVC …x2x1/0.8
| Number of pairs | Diameter of armour wire | External diameter approx. | Copper weight | Cable weight approx. |
|---|---|---|---|---|
| mm | mm | kg/km | kg/km | |
| 4 | 1,25 | 19,2 | 38 | 662 |
| 7 | 1,25 | 21,6 | 66 | 820 |
| 19 | 1,60 | 31,1 | 179 | 1632 |
| 37 | 2,00 | 40,4 | 345 | 2760 |
Factory Overview
Packaging & Shipping
Frequently asked questions and answer ( Q:- A:- )
Q:- What is the primary application of the PE/PJF/PE/SWA/PVC cable?
A:- It is used for control, protection, signaling, telecommunications, and data transmission associated with power distribution and transmission systems.
Q:- What is the key safety feature regarding voltage limits?
A:- The cable is specifically designed to be used in environments where induced voltage can reach up to 15kV, offering enhanced insulation and protection.
Q:- What standards does the cable construction follow?
A:- The construction adheres to ESI 09-6, issue 3 standards, and the conductor complies with BS 6360.
Q:- What type of conductor and insulation does it use?
A:- It uses a solid copper conductor with a PE type 03C insulation according to BS 6234.
Q:- What is the purpose of the jelly filling?
A:- The petroleum-based jelly filling provides longitudinal water-blocking protection to ensure the cable’s reliability in harsh or wet environments.
Q:- What is the mutual capacitance of this cable?
A:- The mutual capacitance at 1000 Hz is max. 40 nF/km.
Q:- What is the test voltage for this cable?
A:- The test voltage is AC for 1 min between each conductor and earth at 15 kV.
Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 15 times the cable diameter.
Q:- What is the conductor resistance at 20°C?
A:- The conductor resistance at 20°C is max. 73.6 MΩ/km.
Q:- How are the pairs arranged in the cable core?
A:- The pairs are arranged in layers, starting with 4 pairs in the first layer and expanding up to 37 pairs across multiple layers.