PVC/SWA/PVC Armoured Control Cable – BS 6346 Standard
The PVC/SWA/PVC cable delivers dependable power and control connections for industrial and domestic applications. Constructed with a solid copper conductor, PVC insulation, galvanized steel wire armour, and an orange PVC outer sheath, it offers exceptional mechanical protection. Because it meets standards similar to BS 6346 and is RoHS compliant, it provides a safe and reliable solution for outdoor, indoor, underground, and in-water installations where mechanical damage is anticipated.
Application
PVC/SWA/PVC cables provide reliable power and control connections for industrial and domestic applications. Because of their steel wire armour, installers use them in outdoor applications, indoor installations, in the open air, underground, and in water where mechanical damage is anticipated. Consequently, they deliver consistent performance in physically demanding environments.
Cable construction
This cable adheres to standards similar to BS 6346. It features a solid copper conductor according to BS 6360 with sizes of 1.0mm² (1/1.13mm) and 1.5mm² (1/1.38mm). The insulation uses a PVC type TI1 compound (according to BS 7655) with a radial thickness of 0.6mm. The wires are stranded into layers, with a wrapping of 1 layer of plastic tape. A PVC compound type TM1 forms the inner sheath. A single layer of galvanized steel wires provides the armour. The outer sheath uses a PVC compound type TM1 (according to BS 7655) in orange color. Furthermore, this product is RoHS compliant.
Technical Data
The cable delivers consistent performance under specific conditions. It maintains a conductor resistance at 20 °C of 18.1 Ω/km for 1.0 mm² and 12.1 Ω/km for 1.5 mm². The mutual capacitance at 800 Hz is max. 120 nF/km for 1.0 mm² and 140 nF/km for 1.5 mm². The insulation resistance is min. 100 MΩ.km. The voltage rating is 300/1000V. The test voltage is 50 Hz, 1 min for 3500V (wire-wire) and 3500V (wire-armour). The temperature range is mobile -5 °C to +50 °C and fixed -30 °C to +70 °C. The minimum bending radius is 15 x cable diameter.
Cable core construction
The cores are arranged in layers based on the number of wires. For 4 wires, all are in the centre. For 8 wires, 1 is in the centre, 7 in the first layer. For 12 wires, 2 are in the centre, 9 in the first layer. For 16 wires, 5 are in the centre, 11 in the first layer. For 20 wires, 7 are in the centre, 13 in the first layer.
Color coding
Clear color coding ensures safe and accurate wiring. Core colors include brown, yellow, green, red, white, blue, black, orange, grey, violet, and specific combinations like red/yellow, black/red, grey/red, and blue/white.
Type codes
PVC = insulation or sheath of PVC, SWA = galvanized steel wires armour.
Constructive Data Table
Please refer to the following comprehensive specifications for precise sizing, weight, and diameter information.
Construction data PVC/SWA/PVC
| Number of wires | Diameter of armour wire | External diameter approx. | Copper weight | Cable weight approx. |
|---|---|---|---|---|
| mm² | mm | mm | kg/km | kg/km |
| 4×1 | 0,9 | 11,9 | 38 | 295 |
| 8×1 | 0,9 | 14,2 | 72 | 418 |
| 12×1 | 1,25 | 16,9 | 108 | 535 |
| 16×1 | 1,25 | 18,6 | 145 | 744 |
| 20×1 | 1,25 | 19,9 | 180 | 835 |
| 4×1,5 | 0,9 | 12,5 | 55 | 330 |
| 8×1,5 | 0,9 | 15,2 | 108 | 480 |
| 12×1,5 | 1,25 | 18,0 | 162 | 635 |
| 16×1,5 | 1,25 | 19,7 | 218 | 875 |
| 20×1,5 | 1,25 | 21,2 | 270 | 1010 |
Factory Overview
Packaging & Shipping
Frequently asked questions and answer ( Q:- A:- )
Q:- What is the primary application of the PVC/SWA/PVC cable?
A:- It is used for outdoor applications, indoor installations, in open air, underground, and in water where mechanical damage is anticipated.
Q:- What are the key mechanical protection features of this cable?
A:- It features a single layer of galvanized steel wires (SWA) that provides robust mechanical protection against damage.
Q:- What standards does the cable construction follow?
A:- The construction adheres to standards similar to BS 6346, and the conductor complies with BS 6360.
Q:- What type of conductor and insulation does it use?
A:- It uses a solid copper conductor with a PVC type TI1 insulation according to BS 7655.
Q:- What is the temperature range for this cable?
A:- The fixed temperature range is -30°C to +70°C, and the mobile temperature range is -5°C to +50°C.
Q:- What is the mutual capacitance of this cable?
A:- The mutual capacitance at 800 Hz is max. 120 nF/km (1.0 mm²) and 140 nF/km (1.5 mm²).
Q:- What is the test voltage for this cable?
A:- The test voltage is 50 Hz, 1 min for 3500V (wire-wire) and 3500V (wire-armour).
Q:- What is the minimum bending radius for installation?
A:- The minimum bending radius is 15 times the cable diameter.
Q:- What is the voltage rating?
A:- The voltage rating is 300/1000V.
Q:- What do the type codes PVC and SWA stand for?
A:- PVC indicates insulation or sheath of PVC, and SWA indicates galvanized steel wires armour.




Reviews